Skip to main content

Allen-Bradley

Allen-Bradley 15AD80H0005 Network Interface for NA386

Allen-Bradley 15AD80H0005 NA386 communication module for PowerFlex 700. Protocol gateway, SCADA/PLC integration, 12-month warranty, global shipping.

SKUCPU/NA386 G.D 15AD80H0005 BrandAllen-Bradley TypeCommunication Module SeriesPowerFlex OriginUS CategoryPLC Systems
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Allen-Bradley 15AD80H0005 Industrial Network Interface for NA386 Series: Bridging the Smart Factory Data Link

The Allen-Bradley 15AD80H0005 is a high-performance communication and CPU board engineered for the NA386 Series within the PowerFlex 700 AC drive platform by Rockwell Automation. Designed to serve as the central intelligence layer between field-level devices and upper-level control systems, this module enables seamless, real-time data exchange across the full automation hierarchy — from signal acquisition at the sensor level all the way to SCADA dashboards and MES platforms in the cloud or on-premise control room.

In modern smart factory environments, the integrity of the industrial data link is non-negotiable. The 15AD80H0005 addresses this requirement by providing robust protocol support, deterministic communication timing, and native compatibility with Rockwell Automation’s integrated architecture. Whether your application involves coordinating multi-axis motion, managing distributed I/O across a production line, or feeding real-time drive telemetry into a FactoryTalk View SCADA system, this module delivers the connectivity backbone your operation demands.

Network Communication Table

Parameter Specification
SKU / Part Number 15AD80H0005
Series NA386 / PowerFlex 700
Brand Allen-Bradley (Rockwell Automation)
Module Type CPU / Communication Board
Protocol Support EtherNet/IP, DeviceNet, ControlNet, DH+
Interface Type Backplane communication, drive-integrated
Transmission Capability Real-time cyclic and acyclic data exchange
Network Compatibility Rockwell Integrated Architecture, SCADA/HMI systems
System Application PowerFlex 700 AC drives, PLC-controlled motor systems, remote I/O nodes
Origin Italy (GD Bologna manufacturing facility)
Warranty 12 Months
Shipping Global — DHL / FedEx Express

Connected Automation Data Flow

The 15AD80H0005 sits at the heart of a layered industrial communication architecture. At the field level, process sensors — including temperature transmitters, pressure transducers, and flow meters — feed analog and digital signals into PowerFlex 700 drives equipped with this CPU board. The module processes these inputs and translates them into structured data packets compatible with EtherNet/IP and DeviceNet protocols, enabling upstream transmission to Allen-Bradley ControlLogix and CompactLogix PLCs without data loss or latency spikes.

Within the control network, the 15AD80H0005 communicates directly with 1756-EN2T EtherNet/IP communication modules installed in ControlLogix chassis, ensuring that drive status, fault codes, speed references, and torque feedback are continuously available to the PLC scan cycle. This data is simultaneously mirrored to PanelView Plus 7 HMI terminals via the same EtherNet/IP backbone, giving operators real-time visibility into drive performance without requiring dedicated point-to-point wiring.

For remote I/O expansion, the module integrates with POINT I/O 1734-AENT EtherNet/IP adapters, allowing distributed I/O nodes located across the production floor to report status back through the same network segment. This eliminates the need for separate communication infrastructure and reduces overall system complexity. In applications where legacy DeviceNet devices — such as photoelectric sensors, proximity switches, and valve actuators — must coexist with modern EtherNet/IP nodes, the 15AD80H0005 acts as a protocol bridge, ensuring backward compatibility without sacrificing throughput.

At the supervisory level, the module’s data stream feeds directly into FactoryTalk View SE SCADA servers, where historians log drive parameters at configurable intervals. This enables trend analysis, predictive maintenance scheduling, and energy consumption reporting — all critical functions in a lean manufacturing or Industry 4.0 environment. Integration with FactoryTalk AssetCentre further supports automated backup of drive configurations, audit trail logging, and remote firmware management, reducing planned downtime during maintenance windows.

For edge computing applications, the 15AD80H0005’s EtherNet/IP output can be aggregated by Cisco IE 4000 industrial managed switches, which segment traffic across VLANs to isolate control data from general IT network traffic. This architecture ensures deterministic communication latency for time-critical control loops while maintaining cybersecurity boundaries between OT and IT networks.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the fragmentation of communication protocols across different generations of equipment. A typical production facility may operate DeviceNet sensors installed a decade ago alongside new EtherNet/IP controllers and PROFINET-capable robots — creating data silos that prevent unified monitoring and control. The Allen-Bradley 15AD80H0005 directly addresses this challenge by providing multi-protocol gateway functionality within the PowerFlex 700 drive platform.

By centralizing protocol translation at the drive level, the 15AD80H0005 eliminates the need for standalone protocol converters or additional gateway hardware between field devices and the control network. Drive fault diagnostics, speed references, current draw, and thermal status are all encapsulated into a single EtherNet/IP data object, accessible to any authorized node on the network — from a ControlLogix PLC to a FactoryTalk View SCADA client running on a remote workstation.

Remote diagnostics capability is a key value proposition of this module. Maintenance engineers can interrogate drive parameters, review fault history, and initiate controlled restarts from any networked HMI or SCADA terminal — without requiring physical access to the drive cabinet. This is particularly valuable in hazardous environments such as chemical processing plants, offshore platforms, or high-voltage electrical rooms where minimizing personnel exposure is a safety priority.

Production line transparency is further enhanced through integration with MES platforms. Real-time OEE (Overall Equipment Effectiveness) calculations can incorporate drive uptime data sourced directly from the 15AD80H0005, enabling production managers to identify bottlenecks, schedule preventive maintenance, and optimize throughput without relying on manual data collection. System scalability is also a core design principle — additional PowerFlex 700 drives equipped with 15AD80H0005 boards can be added to the EtherNet/IP network without reconfiguring the existing communication infrastructure, supporting phased capacity expansion aligned with production growth.

Every unit supplied by ZYPLC undergoes pre-shipment functional testing to verify communication integrity, protocol handshake performance, and firmware version compatibility. Stock is maintained for immediate dispatch, with global delivery via DHL and FedEx Express. All units are covered by a 12-month warranty against manufacturing defects and communication failures.

Industrial Connectivity FAQ

Q1: What communication protocols does the Allen-Bradley 15AD80H0005 support?
The 15AD80H0005 supports EtherNet/IP as its primary industrial Ethernet protocol, with compatibility for DeviceNet and ControlNet within the Rockwell Automation integrated architecture. It is designed for use within the PowerFlex 700 NA386 series drive platform and communicates natively with ControlLogix and CompactLogix PLC families via standard Rockwell communication modules such as the 1756-EN2T.

Q2: How does this module ensure network stability in high-cycle industrial environments?
The 15AD80H0005 uses deterministic EtherNet/IP cyclic communication to maintain consistent scan-cycle synchronization with the host PLC. The module’s backplane interface is designed for continuous operation in industrial temperature ranges, and its firmware supports automatic reconnection in the event of a temporary network interruption, minimizing unplanned downtime in high-cycle applications such as packaging, material handling, and press lines.

Q3: Can the 15AD80H0005 be integrated with third-party SCADA or HMI systems?
Yes. Because the module communicates via EtherNet/IP — an open, IEC-standardized industrial protocol — it is compatible with any SCADA or HMI platform that supports EtherNet/IP implicit or explicit messaging. This includes FactoryTalk View SE, Ignition SCADA, Wonderware System Platform, and other third-party supervisory systems. Configuration is performed through Rockwell’s Studio 5000 Logix Designer software.

Q4: What does the 12-month warranty cover, and what is the lead time for delivery?
The 12-month warranty covers all manufacturing defects, communication failures, and component-level faults identified under normal operating conditions. Units are pre-tested prior to shipment and dispatched from in-stock inventory via DHL or FedEx Express, with typical delivery times of 3–7 business days to most global destinations. Expedited shipping options are available upon request.


© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | plc.sales@zyplc.com