Skip to main content

Allen-Bradley

Allen-Bradley 1757-BEM Battery Extension Module for ProcessLogix Systems

Allen-Bradley 1757-BEM ProcessLogix Battery Extension Module. Protocol-ready, warranty terms confirmed during quotation, tested before shipment where applicable, export shipping options available. RFQ welcome.

SKU1757-BEM BrandAllen-Bradley TypeBattery Extension Module SeriesProcessLogix OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Allen-Bradley 1757-BEM Battery Extension Module is a critical infrastructure component engineered to sustain uninterrupted power continuity within the ProcessLogix distributed control architecture. In modern smart factory environments, where real-time data integrity between field devices, PLC controllers, remote I/O racks, HMI panels, and SCADA supervisory systems is non-negotiable, the 1757-BEM serves as the silent guardian of the entire data chain. By ensuring that the ProcessLogix controller retains its program memory and communication state during power transitions, the 1757-BEM directly protects the continuity of industrial network communication — from signal acquisition at the sensor level all the way to enterprise-level MES and SCADA platforms.

In a typical ProcessLogix deployment, the 1757-BEM is installed alongside the 1757-SRM System Redundancy Module, enabling seamless controller failover without data loss. This redundancy architecture is fundamental to maintaining stable Ethernet/IP and ControlNet communication links between the ProcessLogix controller and downstream devices such as the 1794-AENT FLEX I/O Ethernet Adapter, remote I/O expansion racks, and distributed drive systems. When the primary controller undergoes a power event, the 1757-BEM ensures that the active communication session — including live process variable updates, alarm states, and diagnostic registers — is preserved without interruption.

Compatibility & Integration Notes

Attribute Specification
Compatible Protocol ControlNet, Ethernet/IP, DH+, Remote I/O
Interface Type Backplane Extension Module
Transmission Support Controller Memory Retention during Power Loss
Network Compatibility ProcessLogix R500, R510, R520 Controller Platforms
System Application DCS, PLC Redundancy, SCADA Integration, HMI Continuity
Warranty warranty terms confirmed during quotation | Tested & availability subject to RFQ confirmation

Connected Automation Data Flow

The 1757-BEM operates at the heart of a layered industrial communication architecture. At the field level, sensors and actuators transmit process signals through FLEX I/O modules such as the 1794-IB16 digital input module and 1794-OB16 digital output module, which relay data upstream via the 1794-AENT Ethernet adapter to the ProcessLogix controller. The 1757-BEM ensures that this controller — the central node aggregating all field data — never loses its communication context during a power interruption.

At the network layer, the ProcessLogix system communicates with Rockwell Automation’s FactoryTalk View SE SCADA/HMI platform via Ethernet/IP, delivering real-time process visualization, alarm management, and historian data logging. The 1757-SRM System Redundancy Module works in tandem with the 1757-BEM to execute bumpless controller switchover, ensuring that the FactoryTalk Historian SE continues to receive uninterrupted data streams from the process. Simultaneously, PowerFlex 755 variable frequency drives connected via the DriveLogix embedded controller maintain their speed reference and torque command registers, preventing unplanned motor trips during controller transitions.

For remote diagnostics and predictive maintenance, the ProcessLogix system integrates with Rockwell’s FactoryTalk AssetCentre, which monitors controller health, firmware versions, and communication link quality across the entire ControlNet backbone. The 1757-BEM’s role in this ecosystem is to guarantee that the controller’s diagnostic registers and communication tables remain intact, enabling AssetCentre to deliver accurate asset health reports without data gaps. Edge gateway devices such as the Cisco IE 4000 Industrial Ethernet Switch further extend the network reach, bridging the ProcessLogix ControlNet segment to the plant-wide Ethernet backbone for integration with MES and ERP systems.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in legacy DCS and hybrid PLC environments is data isolation — the inability to maintain a continuous, reliable data flow between heterogeneous control systems, field devices, and supervisory platforms. The Allen-Bradley 1757-BEM directly addresses this challenge within the ProcessLogix ecosystem by eliminating the risk of controller memory loss, which is a primary cause of communication session drops and data inconsistency between the controller and connected SCADA, HMI, and historian systems.

In multi-vendor plant environments where Modbus RTU devices, PROFIBUS field instruments, and Ethernet/IP controllers coexist, protocol fragmentation creates data silos that undermine production transparency. The ProcessLogix platform, supported by the 1757-BEM’s power continuity function, provides a stable communication anchor that protocol gateways and media converters can rely upon for consistent upstream data delivery. This stability is essential for real-time production monitoring dashboards, OEE calculation engines, and alarm management systems that depend on uninterrupted data feeds from the controller layer.

Remote monitoring and diagnostics are further enhanced by the 1757-BEM’s contribution to controller uptime. With the controller remaining online through power events, remote engineers can access live diagnostic data via FactoryTalk Remote Access or VPN-connected SCADA workstations without experiencing session timeouts or data reconnection delays. This capability is particularly valuable in geographically distributed plant networks where on-site intervention is costly and time-consuming. The result is a more transparent, scalable, and maintainable industrial network that supports continuous improvement initiatives and digital transformation roadmaps.

Industrial Connectivity FAQ

Q1: Does the 1757-BEM affect communication latency on the ControlNet or Ethernet/IP network?
No. The 1757-BEM is a passive power extension module that operates at the backplane level. It does not introduce any additional latency to the ControlNet or Ethernet/IP communication cycle. Network scan times and RPI (Requested Packet Interval) settings remain fully determined by the ProcessLogix controller configuration and network topology.

Q2: Is the 1757-BEM compatible with all ProcessLogix controller revisions?
The 1757-BEM is designed for use with the ProcessLogix R500, R510, and R520 controller platforms. Compatibility with specific firmware revisions should be verified against the Rockwell Automation product compatibility matrix. All units supplied by ZYPLC are tested against known-good firmware baselines prior to shipment.

Q3: How does the 1757-BEM support system expansion in growing plant networks?
By ensuring controller memory and communication state retention during power events, the 1757-BEM provides a stable foundation for adding new I/O racks, communication modules, and network segments to the ProcessLogix system. Expansion activities such as adding 1794-AENT adapters or extending the ControlNet trunk can be performed with confidence that the controller will maintain its existing communication tables and program logic intact.

Q4: What quality assurance and warranty coverage is provided with the 1757-BEM?
Every 1757-BEM unit supplied by ZYPLC undergoes a comprehensive pre-shipment functional test, including backplane communication verification, battery retention capacity check, and visual inspection for component integrity. All units are covered by a warranty terms confirmed during quotation from the date of shipment. Availability is confirmed via RFQ for shipment arranged after confirmation via DHL or FedEx express services to global destinations.