Skip to main content

Allen-Bradley

Allen-Bradley 1761-NET-ENI Network Interface for MicroLogix

Allen-Bradley 1761-NET-ENI Ethernet network interface for MicroLogix PLCs. RFQ compatibility review, TCP/IP, warranty terms confirmed during quotation. Global stock, export shipping options available.

SKU1761-ENT-ENI BrandAllen-Bradley TypeEthernet Network Interface SeriesMicroLogix OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

In modern smart factory environments, seamless data flow between field devices, PLC controllers, remote I/O, HMI panels, SCADA platforms, drives, sensors, and supervisory systems is no longer optional — it is the foundation of operational efficiency. The Allen-Bradley 1761-NET-ENI is a dedicated Ethernet network interface module engineered to bring MicroLogix series PLCs into full Ethernet/IP connectivity, enabling real-time data exchange across every layer of the automation hierarchy.

Designed for the MicroLogix 1000, MicroLogix 1100, MicroLogix 1200, and MicroLogix 1500 controller families, the 1761-NET-ENI provides a 10/100 Mbps Ethernet port that supports TCP/IP and Ethernet/IP protocols. It connects directly to the controller’s DH-485 or RS-232 communication port, instantly transforming a serial-only controller into a fully networked node capable of participating in plant-wide data architectures.

Compatibility & Integration Notes

Attribute Specification
System Role Ethernet/IP Network Interface for MicroLogix PLCs
Supported Protocols Ethernet/IP, TCP/IP, DHCP, DNS
Interface Type RJ-45 Ethernet (10/100 Mbps, Auto-Negotiation)
Host Connection RS-232 (DH-485 via 1761-CBL-PM02 cable)
Compatible Controllers MicroLogix 1000, 1100, 1200, 1500
Network Compatibility Standard Ethernet LAN, Industrial Ethernet Switch
Power Supply Powered via host controller or external 24 VDC
Operating Temperature 0°C to 60°C
Mounting DIN Rail or Panel Mount
System Application SCADA Integration, HMI Communication, Remote Programming
Warranty warranty terms confirmed during quotation — Tested and Verified Before Shipment

Connected Automation Data Flow

The 1761-NET-ENI sits at the intersection of legacy serial control and modern Ethernet-based automation. In a typical MicroLogix deployment, the controller — such as a 1761-L16BWA or 1761-L32BWA — handles discrete logic, analog signal processing, and local I/O management. Expansion modules like the 1762-IQ16 (16-point DC input) and 1762-OB16 (16-point DC output) extend the I/O capacity of the base controller, while analog modules such as the 1762-IF4 bring 4-channel analog input capability for process variable monitoring.

Without the 1761-NET-ENI, these controllers are limited to serial programming via RSLinx and local HMI connections. With the module installed and connected via the 1761-CBL-PM02 programming cable to the controller’s RS-232 port, the entire MicroLogix system gains a live Ethernet/IP node address. This enables the PanelView C600 or similar HMI terminals to communicate with the controller over standard Ethernet, eliminating the need for dedicated serial HMI cabling and reducing panel wiring complexity.

At the SCADA layer, the 1761-NET-ENI allows FactoryTalk View SE, Ignition SCADA, or any Ethernet/IP-compatible supervisory platform to poll real-time data tags from the MicroLogix controller at configurable scan rates. Alarm states, production counters, analog process values, and diagnostic flags are all accessible over the network without additional protocol converters. For sites running mixed controller architectures — such as a 1763-L16BWA MicroLogix 1100 alongside a CompactLogix or ControlLogix system — the 1761-NET-ENI ensures the MicroLogix node participates in the same Ethernet/IP fabric, enabling cross-controller data visibility through the SCADA historian.

In drive integration scenarios, the 1761-NET-ENI enables the MicroLogix controller to issue speed references and read status feedback from PowerFlex 4M or PowerFlex 40 variable frequency drives connected via Ethernet-capable drive adapters, closing the loop between process logic and motion control without additional communication gateways. For remote I/O applications, the module supports communication with 1761-NET-AIC advanced interface converters, further extending the network reach of the MicroLogix platform to multi-drop serial device networks.

Solving Data Isolation in Industrial Sites

Many industrial facilities operating MicroLogix controllers face a common challenge: the controllers are reliable and cost-effective, but their native serial interfaces create data silos that prevent plant-wide visibility. Production data remains trapped at the machine level, inaccessible to MES systems, energy management platforms, or remote maintenance teams.

The 1761-NET-ENI directly resolves this data isolation problem. By providing a standards-based Ethernet/IP interface, it allows existing MicroLogix installations to be integrated into modern IIoT architectures without replacing the controller hardware. A single module transforms a serial-only MicroLogix 1200 into a fully networked device that can be monitored, programmed, and diagnosed remotely from any Ethernet-connected workstation on the plant network.

For multi-site operations, the 1761-NET-ENI enables remote programming via RSLogix 500 over VPN, eliminating the need for on-site technician visits for routine parameter changes or firmware updates. Alarm notifications can be routed through SCADA to mobile devices, enabling rapid response to process deviations without continuous on-site staffing. Production line transparency improves immediately: OEE dashboards, shift reports, and energy consumption data become available in real time, supporting data-driven maintenance scheduling and continuous improvement initiatives.

In packaging lines, water treatment facilities, and light manufacturing environments where MicroLogix controllers manage discrete and analog processes, the 1761-NET-ENI provides the connectivity backbone that supports system expansion. Adding new I/O modules, integrating additional sensors, or connecting new HMI stations becomes straightforward once the controller is on the Ethernet network, as all configuration and monitoring can be performed remotely without disrupting ongoing production.

Industrial Connectivity FAQ

Q1: Does the 1761-NET-ENI support both MicroLogix 1000 and MicroLogix 1500 controllers?
Yes. The 1761-NET-ENI is compatible with the full MicroLogix family, including the 1000, 1100, 1200, and 1500 series. It connects via the controller’s RS-232 channel using the 1761-CBL-PM02 cable, and the Ethernet/IP node address is configured through RSLinx Classic or the module’s built-in web interface.

Q2: What is the maximum network transmission speed, and is there any communication latency concern for real-time control?
The 1761-NET-ENI supports 10/100 Mbps Ethernet with auto-negotiation. For typical SCADA polling and HMI communication tasks, latency is well within acceptable limits for MicroLogix-class applications. The module is not designed for motion control or high-speed deterministic communication, but it fully meets the requirements of process monitoring, remote programming, and supervisory data exchange in standard industrial Ethernet environments.

Q3: Is the unit tested before shipment, and what warranty coverage is provided?
Every 1761-NET-ENI unit supplied by ZYPLC undergoes functional testing prior to shipment, including Ethernet port verification, protocol communication checks, and power-on diagnostics. All units are covered by a warranty terms confirmed during quotation from the date of shipment. In the event of a verified hardware fault within the warranty period, ZYPLC provides replacement or repair support with priority handling to minimize downtime impact on your operations.

Q4: Can the 1761-NET-ENI be used to integrate MicroLogix controllers into an existing ControlLogix or CompactLogix Ethernet/IP network?
Yes. Once the 1761-NET-ENI is configured with a valid IP address on the plant Ethernet network, it appears as a standard Ethernet/IP node. ControlLogix and CompactLogix controllers, as well as RSLinx Enterprise and FactoryTalk services, can communicate with the MicroLogix controller through the 1761-NET-ENI using standard Ethernet/IP messaging, enabling cross-platform data exchange and unified network management.