Skip to main content

Bently Nevada

Bently Nevada 330194-17-25-15-00 Proximity Probe for 3300 XL Systems

Bently Nevada 330194-17-25-15-00 3300 XL Proximity Probe for vibration monitoring. Protocol-ready, SCADA/HMI compatible, warranty terms confirmed during quotation. RFQ Available at ZYPLC.

SKU330194-17-25-15-00 BrandBently Nevada TypeProximity Probe Series3301 OriginUS CategorySensors & I/O
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Bently Nevada 330194-17-25-15-00 is a high-precision proximity probe engineered for the 3300 XL Series continuous vibration monitoring system. In modern smart factory environments, reliable signal acquisition at the field device level is the foundation of every data chain — from rotating machinery to SCADA dashboards. This probe delivers the raw displacement and vibration signals that feed directly into the 3300 XL proximitor/driver modules, enabling real-time shaft position monitoring, radial vibration analysis, and axial thrust measurement across critical rotating assets including turbines, compressors, pumps, and gearboxes.

With a 25mm cable length configuration and 15-foot extension cable, the 330194-17-25-15-00 is optimized for installations where precise gap voltage calibration is essential. Its eddy-current sensing principle operates without physical contact, ensuring zero mechanical wear and continuous signal integrity — a critical requirement for 24/7 industrial network uptime.

Compatibility & Integration Notes

Parameter Specification
SKU 330194-17-25-15-00
Brand / Series Bently Nevada / 3300 XL
Sensing Protocol Eddy-Current (Non-contact Displacement)
Signal Output Analog DC Voltage (Gap Voltage)
Interface Type Coaxial Cable / Proximitor Driver Input
Probe Length 25 mm
Extension Cable 15 ft (330130-045-00-CN compatible)
Network Compatibility 3300 XL Proximitor, System 1 Software, SCADA/DCS Integration
Communication Path Analog → Proximitor → 4–20 mA / Modbus / OPC-UA → DCS/SCADA
System Application Turbine, Compressor, Pump, Gearbox Vibration Monitoring
Warranty warranty terms confirmed during quotation
Availability RFQ Available — Ships within 24–48 Hours

Connected Automation Data Flow

In a fully integrated smart factory architecture, the 330194-17-25-15-00 proximity probe sits at the very beginning of the industrial data chain. The probe senses shaft displacement and transmits a continuous analog voltage signal to the Bently Nevada 3300 XL Proximitor/Driver (such as the 330180-X1-05 or 330180-51-00), which conditions and converts the raw signal into a standardized output suitable for upstream processing.

From the proximitor module, the conditioned signal travels to the Bently Nevada 3500/42M Proximitor I/O Module within the 3500 Series rack — a modular platform that aggregates vibration, position, and speed data from multiple field probes simultaneously. The 3500 rack communicates with plant-level systems via Modbus TCP, OPC-UA, or 4–20 mA analog loops, feeding data directly into GE System 1 Evolution or third-party SCADA platforms such as Wonderware, Ignition, or OSIsoft PI.

At the control layer, Allen-Bradley ControlLogix PLCs or Siemens S7-400 controllers receive alarm and trip signals from the 3500 rack via hardwired relay outputs or EtherNet/IP communication cards. These controllers coordinate protective shutdown sequences and feed status data to Rockwell FactoryTalk View SE HMI or Siemens WinCC SCADA stations, where operators monitor shaft centerline plots, orbit diagrams, and trend data in real time.

For remote diagnostics and predictive maintenance, edge gateways such as the Bently Nevada System 1 Remote Monitoring Gateway or third-party IIoT edge devices aggregate OPC-UA data streams and push them to cloud analytics platforms. This enables maintenance engineers to perform remote vibration spectrum analysis, set dynamic alarm thresholds, and receive early-warning notifications — all without physical access to the machine train.

The 330194-17-25-15-00 is also fully compatible with Bently Nevada TK-3 portable vibration analyzers for on-site commissioning and gap voltage verification, ensuring that every probe in the network is correctly calibrated before integration into the live monitoring loop. When combined with 330130-045-00-CN extension cables and 330180 series proximitor drivers, this probe forms a complete, validated sensor chain ready for DCS or SCADA handoff.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial vibration monitoring is data isolation — where field sensors operate in analog silos, disconnected from the plant’s digital control and monitoring infrastructure. The Bently Nevada 330194-17-25-15-00, when deployed within the 3300 XL ecosystem, directly addresses this problem by providing a standardized, protocol-compatible signal path from the machine shaft to the enterprise data layer.

Sites running mixed-vendor environments — where legacy 4–20 mA loops coexist with modern Modbus TCP or OPC-UA networks — benefit from the 3300 XL system’s flexible output architecture. The proximitor modules can simultaneously drive analog outputs for legacy DCS inputs and digital outputs for modern SCADA or historian systems, eliminating the need for costly signal converters or parallel wiring runs.

For production line transparency, the 330194-17-25-15-00 enables continuous, uninterrupted shaft monitoring that feeds real-time KPIs — vibration amplitude, phase angle, and DC gap voltage — directly into MES and ERP dashboards. Maintenance teams gain full visibility into machine health trends without relying on periodic manual inspections, reducing unplanned downtime and extending mean time between failures (MTBF).

System expansion is equally straightforward: additional 330194-series probes can be added to existing 3500 racks without reconfiguring the communication backbone. Each new probe integrates into the existing Modbus or OPC-UA data map, and System 1 software automatically recognizes new measurement points, making the architecture highly scalable for greenfield expansions or brownfield retrofits.

Every 330194-17-25-15-00 unit shipped by ZYPLC undergoes pre-shipment functional testing, including gap voltage verification and cable continuity checks, backed by a warranty terms confirmed during quotation. Availability confirmed by RFQ inventory ensures rapid deployment with global shipping available within 24–48 hours of order confirmation.

Industrial Connectivity FAQ

Q1: What communication protocols does the Bently Nevada 3300 XL system support when integrated with SCADA or DCS?
The 3300 XL proximitor outputs an analog DC voltage signal that is processed by the 3500 Series rack, which supports Modbus TCP, OPC-UA, 4–20 mA analog, and hardwired relay outputs. This multi-protocol architecture ensures compatibility with virtually all major DCS and SCADA platforms, including Honeywell Experion, Emerson DeltaV, Siemens PCS 7, and Rockwell PlantPAx.

Q2: How is communication latency managed in a real-time vibration monitoring network?
The 330194-17-25-15-00 operates as a passive analog sensor with no inherent digital latency. Signal conditioning in the 3300 XL proximitor is performed in hardware, delivering sub-millisecond response times. The 3500 rack’s digital communication cycle (Modbus/OPC-UA) is configurable from 100 ms to 1 second, ensuring that alarm and trip signals reach the PLC or DCS within the required protective response window.

Q3: Can the 330194-17-25-15-00 be used in a mixed-vendor network alongside non-Bently Nevada PLCs and HMIs?
Yes. The 3500 Series rack’s standard analog and digital outputs are vendor-agnostic. The 4–20 mA loop output connects directly to any DCS analog input card, while the Modbus TCP interface is compatible with Allen-Bradley, Siemens, Mitsubishi, and Schneider Electric PLCs. OPC-UA connectivity further ensures seamless integration with any OPC-compliant SCADA or HMI platform.

Q4: What does the warranty terms confirmed during quotation cover, and how is pre-shipment testing conducted?
All 330194-17-25-15-00 units are tested prior to shipment, including eddy-current sensitivity verification, gap voltage calibration check, and cable/connector integrity inspection. The warranty terms confirmed during quotation covers manufacturing defects and functional failures under normal operating conditions. ZYPLC provides full technical support throughout the warranty period, including remote diagnostics assistance and replacement coordination.