Skip to main content

Bently Nevada

Bently Nevada 330851-02-000-050-50-01-CN Proximity Probe for 3300 Series Systems

Bently Nevada 330851-02-000-050-50-01-CN proximity probe for 3300 Series vibration monitoring. Protocol-ready, RFQ Available at ZYPLC.

SKU330851-02-000-050-50-01-CN BrandBently Nevada TypeProximity Probe Series3300 Series OriginUS CategorySensors & I/O
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Bently Nevada 330851-02-000-050-50-01-CN is a high-precision eddy-current proximity probe engineered for the 3300 Series continuous vibration monitoring platform. Designed to operate at the front line of rotating machinery diagnostics, this probe serves as the critical signal-acquisition node in a layered industrial data architecture — capturing shaft displacement, radial vibration, and axial position data that feeds directly into plant-wide SCADA and condition monitoring systems.

In modern smart factory deployments, the data journey begins at the machine surface. The 330851-02-000-050-50-01-CN probe converts mechanical motion into a precise voltage signal, which is then conditioned by the companion Bently Nevada 3300 XL 8mm Extension Cable and routed to the 3300 XL Proximitor Sensor for signal processing. From there, the conditioned output is transmitted to the Bently Nevada 3500/42M Proximitor Seismic Monitor rack module, where real-time vibration data is digitized and made available over standard industrial communication interfaces including Modbus RTU, Modbus TCP/IP, and 4–20 mA analog loops — enabling seamless integration with distributed control systems (DCS), PLCs, and SCADA platforms.

Within a typical turbomachinery protection network, the 330851-02-000-050-50-01-CN operates alongside the Bently Nevada 3500/22M Transient Data Interface, which captures high-resolution transient events and forwards them via Ethernet to historian servers and System 1 condition monitoring software. Operators at the HMI level — whether using GE Proficy iFIX, Wonderware InTouch, or Siemens WinCC — receive live vibration trend data, alarm states, and diagnostic reports without manual intervention. This closed-loop data flow eliminates information silos between the field device layer and the enterprise asset management (EAM) layer.

For facilities integrating legacy instrumentation with modern IIoT infrastructure, the 330851-02-000-050-50-01-CN pairs effectively with protocol gateways such as the Moxa MGate MB3480 or HMS Anybus Communicator, enabling Modbus-to-PROFINET or Modbus-to-EtherNet/IP conversion without rewiring the sensor loop. Remote I/O modules from Bently Nevada’s TDI platform can aggregate multiple probe channels and relay structured data packets upstream to the plant DCS over fiber-optic Ethernet backbones, supporting deterministic communication latency below 10 ms — a requirement for machinery protection in API 670-compliant installations.

The probe’s 50 mm armored cable, 8 mm tip diameter, and CN-suffix connector configuration make it compatible with the full range of 3300 Series Proximitor housings and junction boxes. Its eddy-current sensing principle is immune to oil contamination, humidity, and electromagnetic interference — ensuring signal integrity in harsh environments including compressor trains, steam turbines, gearboxes, and centrifugal pumps. Every unit shipped by ZYPLC undergoes pre-shipment functional verification, including gap voltage calibration and output linearity testing, before dispatch.

Compatibility & Integration Notes

Parameter Specification
SKU 330851-02-000-050-50-01-CN
Brand Bently Nevada
Series 3300 Series
Product Type Eddy-Current Proximity Probe
Communication Protocol Modbus RTU, Modbus TCP/IP, 4–20 mA Analog, HART (via gateway)
Interface Type CN Connector, Coaxial Signal Output
Transmission Capability Shaft displacement, radial vibration, axial position (analog voltage)
Network Compatibility DCS, SCADA, PLC, IIoT Gateway, Historian
System Application Turbomachinery Protection, Condition Monitoring, Predictive Maintenance
Cable Length 50 mm (probe body); extension cable sold separately
Tip Diameter 8 mm
Operating Standard API 670 Compatible
Warranty
Origin USA
Availability RFQ Available — shipment arranged after confirmation

Connected Automation Data Flow

The 330851-02-000-050-50-01-CN sits at the origin of a multi-layer industrial data chain. At the field level, the probe tip maintains a calibrated gap to the rotating shaft, generating a voltage output proportional to displacement. This signal travels through the Bently Nevada 330130-080-00-00 Extension Cable to the 3300 XL Proximitor Sensor (330180-X1-05), which conditions and linearizes the output before passing it to the Bently Nevada 3500/42M rack monitor.

The 3500 rack communicates over Modbus TCP/IP to the plant’s Emerson DeltaV DCS or Honeywell Experion PKS, where vibration values are logged at 1-second intervals and compared against API 670 alarm setpoints. Simultaneously, the Bently Nevada 3500/22M Transient Data Interface captures startup and shutdown transient waveforms, forwarding them via Ethernet to System 1 Evolution software for spectral analysis and bearing fault detection.

At the SCADA layer, operators using GE Proficy Historian or OSIsoft PI can query historical vibration trends, generate compliance reports, and configure remote alarm notifications — all without physical access to the machinery. Edge computing nodes, such as the Advantech WISE-5231 IIoT gateway, can further aggregate multi-channel probe data and publish structured JSON payloads to cloud-based asset performance management (APM) platforms, completing the digital thread from sensor to enterprise.

Solving Data Isolation in Industrial Sites

Many industrial facilities operate with fragmented instrumentation ecosystems — legacy vibration monitors using proprietary analog outputs, newer DCS platforms expecting digital Modbus or PROFINET data, and SCADA systems unable to access real-time machinery health without manual data entry. The Bently Nevada 330851-02-000-050-50-01-CN, when deployed within the 3300/3500 Series architecture, directly addresses these integration gaps.

By standardizing on the 3500 rack’s Modbus TCP/IP gateway capability, plant engineers can bridge the analog sensor layer to any modern control network without replacing field wiring. Protocol conversion gateways handle the translation to PROFIBUS DP, EtherNet/IP, or OPC-UA as required by the upstream DCS or MES platform. This approach eliminates data silos between the rotating equipment layer and the production management layer, enabling real-time production transparency — operators can correlate vibration anomalies with process upsets, reducing downtime and improving overall equipment effectiveness (OEE).

Remote diagnostics become possible once the probe data is accessible over the plant network: maintenance engineers can review vibration spectra, configure alarm thresholds, and acknowledge alerts from any networked workstation or mobile device. System expansion is equally straightforward — additional 330851-series probes can be added to spare rack slots without network reconfiguration, supporting phased rollouts across multiple machine trains.

ZYPLC maintains availability subject to RFQ confirmation of the 330851-02-000-050-50-01-CN and ships globally with full documentation. Each unit is tested prior to shipment and covered by a against manufacturing defects.

Industrial Connectivity FAQ

Q1: What communication protocols does the Bently Nevada 3300/3500 Series support for SCADA integration?
The 3500 rack system supports Modbus RTU (RS-485), Modbus TCP/IP (Ethernet), and 4–20 mA analog outputs natively. With optional gateway modules or third-party protocol converters, the system can also communicate via PROFIBUS DP, EtherNet/IP, and OPC-UA, making it compatible with virtually all major DCS and SCADA platforms.

Q2: What is the typical communication latency for vibration alarm signals from the 330851-02-000-050-50-01-CN to the DCS?
Within the 3500 rack architecture, alarm relay outputs respond in under 1 ms to a trip condition. Modbus TCP/IP polling cycles are typically configured at 500 ms to 1-second intervals for continuous monitoring, with hardware relay outputs providing instantaneous protection-grade response independent of network latency.

Q3: Is the 330851-02-000-050-50-01-CN compatible with third-party vibration monitoring systems?
The probe outputs a standard eddy-current voltage signal (typically –24 VDC bias, linear range –2 to –18 VDC) compatible with any Bently Nevada 3300 Series Proximitor. While optimized for the 3300/3500 ecosystem, the analog output can be interfaced to third-party monitors that accept equivalent input specifications. Protocol-level integration with non-Bently systems is achieved via the 3500 rack’s Modbus gateway.

Q4: What does the from ZYPLC cover, and how is it validated?
ZYPLC’s covers manufacturing defects and functional failures under normal operating conditions. Each 330851-02-000-050-50-01-CN unit undergoes pre-shipment gap voltage calibration and output linearity verification. Warranty claims are supported with test records provided at the time of shipment. Contact ZYPLC at plc.sales@zyplc.com or +86 19859288691 for warranty service.