Skip to main content

GE Fanuc

GE IC200ACC414A PLC Battery for VersaMax Systems

GE IC200ACC414A VersaMax Micro PLC battery. Protocol-ready, warranty terms confirmed during quotation, availability subject to RFQ confirmation. Supports GE VersaMax Micro controllers in smart factory networks.

SKUIC200ACC414A BrandGE Fanuc TypePLC Battery SeriesFanuc OriginUS CategoryPLC Systems
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The GE IC200ACC414A is a precision replacement battery engineered for the GE VersaMax Micro PLC series — a cornerstone of industrial automation architectures where uninterrupted power backup is not optional, but mission-critical. In modern smart factory environments, the IC200ACC414A sustains real-time clock (RTC) data retention and SRAM program memory across the VersaMax Micro controller platform, ensuring that communication parameters, ladder logic programs, and network configuration data survive power interruptions without loss. This makes it an indispensable component in any industrial connectivity chain where data integrity directly impacts production continuity.

Compatibility & Integration Notes

Attribute Specification
SKU / Part Number IC200ACC414A
Brand / Manufacturer GE Fanuc (now Emerson / Proficy)
Series Compatibility VersaMax Micro PLC Series
Compatible Controllers IC200UDR002, IC200UDR005, IC200UDD020, IC200UDD040, IC200UAL005, IC200UAR028
Protocol Support SRTP, Modbus RTU, SNP/SNPx (via host controller)
Communication Role RTC & SRAM memory retention during power loss
Interface Type Internal battery module (direct board-mount)
Network Compatibility Profibus, DeviceNet, Ethernet/IP (via IC200PBI001 / IC200BEM002 modules)
System Application PLC program retention, RTC synchronization, SCADA data continuity
Warranty 12 Months
Stock Status RFQ Available — shipment arranged after confirmation
Shipping DHL / FedEx Global Express

Connected Automation Data Flow

In a fully integrated VersaMax Micro automation cell, the IC200ACC414A battery plays a silent but vital role in sustaining the data flow chain. Consider a typical smart factory deployment: field sensors and actuators feed analog and digital signals into the GE VersaMax Micro IC200UDR005 controller via its onboard I/O. The controller processes these signals using ladder logic stored in SRAM — memory that the IC200ACC414A protects during any power interruption. Without this battery, a momentary power dip would erase the program, halt the PLC, and sever the entire data link between the field layer and the supervisory layer.

Moving up the network stack, the VersaMax Micro communicates with upstream systems through serial or Ethernet interfaces. When paired with the IC200PBI001 Profibus Slave Module, the controller participates in a Profibus DP network alongside variable frequency drives, remote I/O racks, and distributed sensor nodes. The IC200ACC414A ensures that the Profibus node address, baud rate, and communication parameters stored in the PLC’s non-volatile memory remain intact across power cycles. Similarly, when the IC200BEM002 Ethernet Interface Module is deployed, the VersaMax Micro connects to plant-wide Ethernet/IP networks, enabling real-time data exchange with SCADA platforms such as GE Proficy iFIX or Wonderware InTouch.

In multi-node architectures, the VersaMax Micro often operates alongside GE PACSystems RX3i controllers acting as master PLCs, with the VersaMax Micro handling local I/O expansion and edge-level control. The IC200ACC414A battery ensures that the slave node’s configuration — including its SNP/SNPx communication address and I/O mapping — is preserved even when the master initiates a network restart. Remote I/O modules such as the IC200CHS022 VersaMax I/O Carrier depend on the PLC’s retained program to correctly map field signals to the SCADA historian.

At the HMI layer, operators interact with the VersaMax Micro system through panels such as the GE QuickPanel+ IC755CSS10CDB, which communicates via Ethernet or serial links. The RTC data maintained by the IC200ACC414A ensures that time-stamped alarm logs, production batch records, and event histories remain accurate — a requirement for MES (Manufacturing Execution System) integration and regulatory compliance in pharmaceutical, food processing, and automotive assembly environments.

For remote diagnostics, the VersaMax Micro’s retained program allows maintenance engineers to reconnect via GE Proficy Machine Edition programming software after a power event and immediately verify that the controller’s logic, I/O configuration, and communication settings are intact — eliminating the need for on-site reprogramming and reducing mean time to repair (MTTR). In edge computing deployments, the VersaMax Micro may feed data to an industrial edge gateway running OPC-UA or MQTT brokers, where data continuity from the PLC layer is essential for cloud-based analytics and predictive maintenance platforms.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in legacy industrial environments is data isolation — where PLCs, drives, sensors, and HMIs operate on incompatible protocols, creating information silos that prevent plant-wide visibility. The GE IC200ACC414A addresses this challenge indirectly but powerfully: by ensuring that the VersaMax Micro PLC retains its full communication configuration across power events, it eliminates a common root cause of protocol mismatches and network dropouts that occur when a PLC loses its settings and reverts to factory defaults.

In plants where Modbus RTU devices — such as energy meters, flow controllers, and temperature transmitters — communicate with the VersaMax Micro via RS-485 serial links, a battery failure can cause the PLC to lose its Modbus master configuration, effectively isolating all downstream field devices from the SCADA system. The IC200ACC414A prevents this scenario, maintaining the Modbus register map, polling intervals, and device addresses that define the plant’s data acquisition architecture.

For production line transparency, the VersaMax Micro’s retained program enables continuous OEE (Overall Equipment Effectiveness) data collection, feeding real-time throughput, downtime, and quality metrics to MES and ERP systems. Remote monitoring becomes reliable when the PLC’s network identity and communication parameters are guaranteed to survive power interruptions — a guarantee that the IC200ACC414A provides. System expansion is also simplified: when adding new I/O modules or communication interfaces to the VersaMax Micro rack, the existing program and network configuration remain intact, allowing engineers to integrate new devices without a full system restart or reprogramming cycle.

Industrial Connectivity FAQ

Q1: Will the IC200ACC414A affect communication latency in my VersaMax Micro network?
No. The IC200ACC414A is a passive memory retention battery and has no active role in data transmission. It does not introduce any latency into Profibus, Modbus RTU, Ethernet/IP, or SNP/SNPx communication cycles. Its function is exclusively to preserve SRAM program data and RTC values during power-off states.

Q2: Is the IC200ACC414A compatible with all VersaMax Micro PLC models?
The IC200ACC414A is designed for the GE VersaMax Micro PLC series, including models such as the IC200UDR002, IC200UDR005, IC200UDD020, IC200UDD040, IC200UAL005, and IC200UAR028. Always verify compatibility against your specific controller’s hardware manual before installation.

Q3: How does battery failure impact network stability and SCADA integration?
A depleted IC200ACC414A battery will cause the VersaMax Micro to lose its stored program, RTC data, and communication parameters upon the next power cycle. This results in the PLC reverting to factory defaults, which can disrupt Profibus node addressing, Modbus register mapping, and Ethernet/IP connection settings — effectively disconnecting the controller from the SCADA network until reprogrammed. Proactive battery replacement is strongly recommended as part of preventive maintenance schedules.

Q4: What quality assurance and warranty coverage does ZYPLC provide for the IC200ACC414A?
Every IC200ACC414A unit shipped by ZYPLC undergoes pre-shipment functional verification to confirm battery voltage and capacity within manufacturer specifications. All units are covered by a warranty terms confirmed during quotation against manufacturing defects. Availability is confirmed via RFQ for shipment arranged after confirmation via DHL or FedEx Express, with tracking provided. For technical support or bulk procurement inquiries, contact our industrial automation team directly.