Skip to main content

GE

GE IC695CHS016LT 16-Slot Chassis for RX3i

GE IC695CHS016LT 16-slot RX3i chassis with RFQ compatibility review support. warranty terms confirmed during quotation. RFQ Available, tested, export shipping options available. Contact ZYPLC today.

SKUIC695CHS016LT BrandGE TypeChassis SeriesPACSystems OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

GE IC695CHS016LT 16-Slot Chassis for RX3i

The GE IC695CHS016LT is a 16-slot universal backplane chassis engineered for deployment within the GE PACSystems RX3i control platform. As the structural and electrical backbone of the RX3i rack system, this chassis defines the physical and logical boundaries of the control node — accommodating CPU modules, power supplies, I/O modules, communications processors, and specialty function cards within a single unified backplane. In layered industrial automation architectures, the chassis is not merely a mounting structure; it is the integration hub that determines system density, expansion capacity, signal routing integrity, and long-term maintainability.

In a complete PACSystems RX3i control architecture, the IC695CHS016LT operates at the control layer, providing 16 module slots that can be populated with a combination of the IC695CPE330 or IC695CPE400 CPU modules, IC695PSA040 or IC695PSD040 power supply modules, and a wide range of IC694 and IC695 series I/O modules. The chassis backplane supports both the legacy 90-30 I/O bus and the high-speed RX3i PCI backplane simultaneously, enabling seamless integration of mixed module generations — a critical advantage in brownfield modernization projects where existing IC693 or IC694 series I/O assets must be preserved alongside newer high-performance modules.

From a system architecture perspective, the 16-slot form factor of the IC695CHS016LT provides the highest module density available in the RX3i chassis family, making it the preferred choice for complex control nodes that require extensive local I/O, redundant communications, or multi-protocol gateway functions within a single rack. When paired with the IC695RMX128 reflective memory module or the IC695ETM001 Ethernet communications module, the chassis supports high-availability architectures with deterministic data exchange across control nodes — essential in power generation, petrochemical processing, and water treatment applications where unplanned downtime carries significant operational and safety consequences.

Product Specification Table

Parameter Specification
System Role 16-Slot Universal Backplane Chassis — PACSystems RX3i Control Node
Module Slots 16 (supports IC694 and IC695 series modules)
Backplane Bus Dual-bus: RX3i PCI high-speed bus + legacy 90-30 I/O bus
Power Input Via dedicated power supply slot (IC695PSA040 / IC695PSD040)
Operating Voltage 24 VDC or 120/240 VAC depending on power supply module selected
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Communication Capability Supports Ethernet (SRTP, Modbus TCP), Profibus, DeviceNet, and serial protocols via plug-in communications modules
Mounting DIN rail or panel mount; standard 19-inch rack compatible
Certifications UL, CE, cUL; suitable for Class I Division 2 hazardous locations
Warranty warranty terms confirmed during quotation — covered by ZYPLC quality assurance program

System Compatibility Notes

The IC695CHS016LT achieves its full architectural value when integrated as part of a coordinated PACSystems RX3i control system. A typical high-density control node built around this chassis would include the IC695CPE330 dual-core CPU module occupying the dedicated CPU slot, supported by the IC695PSA040 40-watt AC power supply module providing stable backplane power distribution across all 16 slots. For applications requiring deterministic real-time control with redundant communications, the IC695ETM001 dual-port Ethernet module enables simultaneous SRTP and Modbus TCP communication on isolated network segments, while the IC695PBM300 Profibus master module extends the control node’s reach to distributed field devices on legacy Profibus DP networks.

On the I/O side, the chassis accommodates mixed populations of IC694MDL754 32-point 24VDC discrete output modules and IC694ALG222 analog input modules for process variable acquisition, enabling the control node to handle both high-density digital switching and precision analog signal processing within the same backplane. For applications requiring high-speed counter inputs or motion coordination, the IC695HSC304 high-speed counter module can be installed in any universal slot, providing quadrature encoder feedback integration without requiring an external motion controller.

In redundant CPU architectures, two IC695CHS016LT chassis are typically deployed in a primary/secondary configuration, with the IC695RMX128 reflective memory module installed in both chassis to maintain synchronized memory images across the redundant pair. This configuration, combined with the IC695CHS016LT‘s support for hot-standby switchover, ensures control continuity during CPU faults or scheduled maintenance windows — a requirement in continuous process industries such as oil refining, chemical manufacturing, and power distribution substations. Terminal block assemblies such as the IC694TBB032 provide field wiring termination at the I/O module level, completing the signal chain from field instrument to backplane without intermediate junction boxes.

Industrial Application Notes

In manufacturing automation, the IC695CHS016LT serves as the primary control chassis in machine-level controllers managing multi-axis assembly lines, robotic welding cells, and automated material handling systems. Its 16-slot capacity allows a single chassis to consolidate discrete I/O, analog process control, motion coordination, and network communications — reducing panel footprint and simplifying inter-controller wiring in high-density production environments.

In electrical power distribution and substation automation, the chassis supports IEC 61850-compatible communications through plug-in protocol gateway modules, enabling integration with protection relays, energy meters, and SCADA systems over standard Ethernet infrastructure. The chassis’s dual-bus backplane architecture ensures that legacy protective relay I/O wired to 90-30 compatible modules continues to operate alongside modern IEC 61850 GOOSE messaging without protocol conversion overhead.

In petrochemical and refinery process control, the IC695CHS016LT is deployed in safety-instrumented system (SIS) adjacent architectures where the basic process control system (BPCS) must maintain strict signal segregation from safety logic. The chassis’s modular slot allocation allows dedicated I/O zones for process control signals and separate zones for interlock and shutdown logic, supporting functional safety design principles without requiring separate physical cabinets.

Water treatment and municipal utility applications benefit from the chassis’s wide operating temperature range and humidity tolerance, enabling installation in outdoor control enclosures and remote pump station panels where environmental conditioning may be limited. The chassis’s compatibility with the IC695CHS016LT expansion rack system allows distributed I/O expansion across multiple physical locations within the same plant, connected via the RX3i rack-to-rack expansion cable system.

Product Compatibility FAQ

Q1: Is the IC695CHS016LT compatible with both IC694 and IC695 series modules, and can they be mixed in the same chassis?
Yes. The IC695CHS016LT features a dual-bus backplane that supports both the legacy 90-30 I/O bus (used by IC694 series modules) and the high-speed RX3i PCI bus (used by IC695 series modules) simultaneously. IC694 and IC695 modules can be freely mixed across the 16 available slots, with the exception of the CPU slot and power supply slot which are reserved for IC695 series CPU and power supply modules respectively. This mixed-generation compatibility is a key advantage for system integrators managing phased modernization projects.

Q2: What redundancy configurations are supported when using the IC695CHS016LT as the primary control chassis?
The IC695CHS016LT supports hot-standby CPU redundancy when paired with a secondary RX3i chassis of the same type and the IC695RMX128 reflective memory module installed in both chassis. In this configuration, the primary and secondary CPUs maintain synchronized memory images with sub-100ms switchover time upon primary CPU fault detection. Additionally, the chassis supports redundant power supply configurations using dual IC695PSD040 DC power supply modules, providing power path redundancy without chassis replacement. Network-level redundancy is achieved through the IC695ETM001 dual-port Ethernet module’s support for Device Level Ring (DLR) topology.

Q3: What does the warranty terms confirmed during quotation cover, and what is the process for warranty claims on the IC695CHS016LT?
The warranty terms confirmed during quotation provided by ZYPLC covers manufacturing defects, backplane electrical failures, and module slot connector integrity under normal operating conditions as defined in the GE PACSystems RX3i hardware reference manual. Warranty claims are initiated by contacting ZYPLC technical support at plc.sales@zyplc.com or +86 19859288691 with the product serial number, purchase documentation, and a description of the observed fault. ZYPLC will provide return merchandise authorization (RMA) within 2 business days and complete repair or replacement within the warranty period. All warranty units are functionally tested against GE factory acceptance criteria prior to return shipment.