Skip to main content

GE Automation (Emerson)

GE IC695ETM001-CC Ethernet Module for RX3i

GE IC695ETM001-CC Ethernet module for PACSystems RX3i. Reduces CPU overhead, optimizes drive control & energy use. RFQ Available, warranty terms confirmed during quotation. ZYPLC.

SKUIC695ETM001-CC BrandGE Automation (Emerson) TypeEthernet Communication Module SeriesPACSystems OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

GE IC695ETM001-CC Ethernet Module for RX3i Automation

In modern industrial environments where every watt and every millisecond counts, the GE IC695ETM001-CC Ethernet communication module delivers the network-layer efficiency that PACSystems RX3i platforms demand. Designed for high-throughput, low-latency Ethernet communication, this module enables precise data exchange between the RX3i controller backplane and upstream SCADA systems, HMI panels, and distributed I/O nodes — all while minimizing the CPU overhead that drives unplanned downtime risk in the control cabinet.

Product Specification Table

Parameter Specification
SKU IC695ETM001-CC
Series PACSystems RX3i
Communication Protocol Ethernet/IP, SRTP, Modbus TCP
Network Speed 10/100 Mbps Auto-Negotiation
Power Consumption ≤3.5 W (typical operating)
Operating Efficiency Optimized for low CPU cycle overhead
Compatible Systems PACSystems RX3i (IC695 series backplane)
Application Environment Industrial automation, process control, maintenance planning
Value Reduces polling latency, lowers redundant data retransmission
Warranty warranty terms confirmed during quotation — tested and verified before shipment

System Compatibility and Application

The IC695ETM001-CC does not operate in isolation — its true efficiency value emerges when integrated into a well-designed PACSystems RX3i automation architecture. At the controller level, the IC695CPE400 CPU module coordinates all logic execution and communicates with the ETM001-CC to push real-time process data upstream with minimal scan-cycle impact. Power delivery to the backplane is managed by the IC695PSD140 power supply module, which maintains stable DC rail voltage and contributes to overall cabinet energy balance.

On the I/O side, analog data from field instruments is collected through the IC695ALG600 analog input module, feeding operating load metrics — motor current draw, drive load percentage, thermal readings — directly into the RX3i controller for closed-loop maintenance planning. For high-speed discrete event capture, the IC695HSC308 high-speed counter module tracks encoder pulses and production cycle counts, enabling the controller to calculate real-time OEE and adjust drive setpoints accordingly.

Communication with variable frequency drives and servo amplifiers on the production floor is handled via the IC695PBM300 PROFIBUS master module, which coordinates torque and speed commands to connected motor drives. When Ethernet-based drive communication is preferred, the ETM001-CC itself bridges the RX3i controller to EtherNet/IP-compatible drives, eliminating the need for additional gateway hardware and reducing both wiring complexity and standby power draw.

For remote I/O expansion across large plant floors, the IC695NIU001 network interface unit extends the RX3i backplane over Ethernet, allowing distributed I/O racks to participate in the same condition monitoring loop without dedicated fieldbus cabling. HMI visualization of energy KPIs is delivered through Proficy-compatible operator panels connected via the ETM001-CC’s SRTP channel, giving operators real-time visibility into drive efficiency, motor load trends, and production throughput — all from a single Ethernet segment.

Maintenance and Replacement Notes

In a typical discrete manufacturing environment, unoptimized Ethernet communication contributes to hidden unplanned downtime: excessive polling cycles keep CPUs at elevated utilization, redundant data retransmission increases network switch load, and poorly timed I/O updates force drives to hold torque longer than necessary between controller scan cycles. The IC695ETM001-CC addresses each of these inefficiencies directly.

Its auto-negotiation capability ensures the module always operates at the optimal link speed for the connected infrastructure, avoiding the power overhead of forced full-duplex 100 Mbps operation on legacy 10 Mbps segments. The module’s SRTP implementation allows the RX3i CPU — such as the IC695CPE310 — to push data only when values change, rather than broadcasting full register maps on every scan. This event-driven communication model reduces average network utilization during steady-state production, directly lowering the thermal load on network switches and reducing cooling energy requirements in the control cabinet.

For energy-intensive processes such as compressor control, pump scheduling, and conveyor synchronization, the IC695ETM001-CC enables the RX3i controller to receive real-time feedback from power monitoring devices — including the IC200ALG230 analog output module used to command variable-speed drives — and dynamically adjust motor setpoints based on actual load demand rather than fixed speed profiles. This demand-responsive control strategy is one of the most effective methods for reducing motor load in continuous process applications, often yielding Actual operating results depend on the installed system, load profile, and commissioning parameters.

Predictive maintenance integration is another key maintenance planning pathway enabled by the IC695ETM001-CC. By streaming vibration, temperature, and current signature data from field sensors through the RX3i backplane to a Proficy Historian or edge analytics platform, maintenance teams can identify bearing wear, winding degradation, and coupling misalignment before they cause unplanned downtime. Eliminating a single 4-hour unplanned stoppage on a high-throughput line can recover more energy value than months of incremental efficiency tuning — making reliable, low-latency Ethernet communication a foundational element of any industrial energy strategy.

Every IC695ETM001-CC unit shipped by ZYPLC undergoes full functional testing under load conditions, verifying Ethernet link establishment, SRTP session integrity, and register read/write performance before dispatch. Units are sourced from verified supply channels, inspected for firmware revision compatibility, and covered by a warranty terms confirmed during quotation from the date of shipment.

Product Sourcing FAQ

Q: How does the IC695ETM001-CC contribute to reducing operating load in a PACSystems RX3i system?
A: By enabling event-driven SRTP communication and efficient EtherNet/IP I/O scanning, the IC695ETM001-CC reduces CPU polling overhead and network retransmission rates. This lowers the average utilization of both the RX3i CPU and connected network infrastructure, reducing heat generation and cooling load in the control cabinet — translating directly into measurable operational stability over continuous operation.

Q: Is the IC695ETM001-CC compatible with third-party drives and SCADA systems?
A: Yes. The module supports Modbus TCP, EtherNet/IP, and SRTP protocols, making it compatible with a wide range of industrial SCADA platforms, HMI systems, and EtherNet/IP-capable variable frequency drives. It integrates natively with GE Proficy Machine Edition and Proficy SCADA environments, and can communicate with non-GE devices that support standard industrial Ethernet protocols.

Q: Can this module replace a faulty IC695ETM001 (non-CC variant) without reprogramming?
A: The IC695ETM001-CC is the current production revision of the IC695ETM001 and is designed as a drop-in replacement for the original variant in most PACSystems RX3i configurations. Firmware and hardware revision compatibility should be verified against the installed CPU firmware version. ZYPLC’s technical team can assist with compatibility confirmation prior to shipment.

Q: What does the warranty terms confirmed during quotation cover, and what is the testing process?
A: All IC695ETM001-CC units are tested for Ethernet link integrity, protocol communication, and register I/O performance before shipment. The warranty terms confirmed during quotation covers hardware defects and functional failures under normal operating conditions. Units that fail during the warranty period are replaced or repaired at no additional cost. Contact ZYPLC’s support team for RMA procedures and technical assistance.