GE IC695PBS301 PROFIBUS DP Slave Module for PACSystems RX3i. RFQ compatibility review, warranty terms confirmed during quotation. RFQ Available & tested. Contact ZYPLC.

SKUIC695PBS301 BrandGE TypePLC Communication Module SeriesFanuc OriginUS CategoryPLC Systems
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

GE IC695PBS301 PROFIBUS DP Slave for RX3i

The GE IC695PBS301 is a PROFIBUS DP Slave Communication Module engineered for seamless integration within the GE PACSystems RX3i control platform. Rather than functioning as a standalone peripheral, the IC695PBS301 occupies a critical position in the layered automation architecture — bridging the RX3i backplane environment with field-level PROFIBUS DP networks that connect sensors, actuators, drives, and distributed I/O stations across industrial facilities. In complex control systems where communication reliability directly determines process uptime, this module delivers the deterministic data exchange and protocol consistency that system architects demand.

The IC695PBS301 is designed to operate within the Universal Backplane of the PACSystems RX3i chassis, communicating directly with the CPU module — such as the IC695CPU310 or IC695CPU315 — through the high-speed backplane bus. This tight integration ensures that PROFIBUS DP slave data is available to the controller with minimal latency, supporting real-time process control loops in demanding environments. The module supports the full PROFIBUS DP-V0 and DP-V1 protocol stack, enabling cyclic and acyclic data exchange with PROFIBUS DP master controllers from GE and third-party vendors alike.

From a system architecture perspective, the IC695PBS301 enables the RX3i rack to participate as a slave node in a PROFIBUS DP network managed by an upstream master — whether that master is another GE PACSystems controller, a Siemens S7-series CPU, or a dedicated PROFIBUS DP master card. This makes the module particularly valuable in hybrid automation environments where multiple control platforms must coexist and share process data across a common fieldbus backbone.

Product Specification Table

Parameter Specification
System Role PROFIBUS DP Slave Communication Module
Compatible Platform GE PACSystems RX3i (IC695 Series)
Protocol Support PROFIBUS DP-V0, DP-V1
Network Role Slave Node (configurable GSD-based)
Max I/O Data 244 bytes input / 244 bytes output
Baud Rate 9.6 kbps – 12 Mbps (auto-detect)
Backplane Interface RX3i Universal Backplane Bus
Power Consumption Supplied via RX3i backplane (3.3V / 5V)
Operating Temperature 0°C to 60°C
Relative Humidity 5% to 95% non-condensing
Mounting RX3i Universal Backplane slot (any I/O slot)
Connector 9-pin D-sub female (PROFIBUS standard)
Certification CE, UL, cUL
system integration Full GSD file support for master configuration
Warranty warranty terms confirmed during quotation

System Compatibility Notes

The IC695PBS301 achieves its full value when considered within the broader PACSystems RX3i control architecture. At the controller layer, the module works in direct coordination with the IC695CPU310 or IC695CPU315 CPU module, which executes the ladder logic or structured text programs that process the PROFIBUS slave data. The CPU reads input data from the IC695PBS301 and writes output data back to it on every scan cycle, maintaining deterministic control over the connected PROFIBUS DP master network.

Power integrity for the entire RX3i chassis — including the IC695PBS301 — is maintained by the IC695PSA040 or IC695PSD040 power supply module, which provides regulated backplane power across all installed modules. Stable power delivery is essential for communication modules, as voltage fluctuations can cause PROFIBUS network instability and data corruption.

On the I/O layer, the RX3i system may simultaneously host analog input modules such as the IC695ALG600 or digital output modules such as the IC694MDL754, all sharing the same backplane and CPU scan. The IC695PBS301 extends this I/O capability across the PROFIBUS network, allowing remote distributed I/O stations — such as GE VersaMax Remote I/O drops or third-party PROFIBUS DP slaves — to be addressed as if they were local rack modules.

For applications requiring network redundancy or multi-master configurations, the IC695PBS301 can be paired with Ethernet communication modules such as the IC695ETM001, enabling the RX3i system to simultaneously participate in both PROFIBUS DP and Ethernet/IP networks. This dual-network capability is critical in modern hybrid automation architectures where SCADA systems communicate over Ethernet while field devices remain on legacy PROFIBUS networks.

At the human-machine interface layer, operator panels and SCADA workstations connect to the PACSystems RX3i via the IC695ETM001 Ethernet module, retrieving process data that originates from PROFIBUS DP field devices through the IC695PBS301. This complete data path — from field sensor through PROFIBUS slave module, across the backplane to the CPU, and out via Ethernet to the HMI — represents the full system integration that modern industrial automation demands.

Terminal modules and marshalling panels within the control cabinet connect field wiring to the PROFIBUS DP cable, which then interfaces with the IC695PBS301’s 9-pin D-sub connector. Proper cable shielding, termination resistors at both ends of the PROFIBUS segment, and correct node addressing are essential installation steps that directly affect communication reliability and long-term maintenance efficiency.

Industrial Application Notes

In manufacturing automation, the IC695PBS301 enables PACSystems RX3i controllers to participate as slave nodes in plant-wide PROFIBUS DP networks managed by central DCS or PLC master controllers. Assembly lines, robotic welding cells, and conveyor systems frequently use PROFIBUS DP as the primary fieldbus, and the IC695PBS301 allows RX3i-based machine controllers to integrate seamlessly into these networks without gateway devices.

In power generation and electrical distribution applications, the IC695PBS301 supports integration of RX3i controllers into substation automation systems where PROFIBUS DP is used to communicate between protection relays, motor control centers, and supervisory controllers. The module’s support for DP-V1 acyclic services enables parameter reading and diagnostic data retrieval from intelligent field devices, supporting condition monitoring and predictive maintenance programs.

In petrochemical and process industries, where continuous process control demands high communication reliability, the IC695PBS301’s auto-baud-rate detection and robust error handling ensure stable operation even in electrically noisy environments. The module’s compatibility with standard GSD files simplifies integration into existing PROFIBUS DP master configurations, reducing engineering time during plant expansions or control system upgrades.

Water treatment facilities, mining operations, and metallurgical plants benefit from the IC695PBS301’s ability to connect RX3i controllers to distributed field instrument networks across large geographic areas. PROFIBUS DP’s support for cable runs up to 1,200 meters at lower baud rates makes it well-suited for these spread-out process environments, and the IC695PBS301 enables full participation in these networks from within the RX3i architecture.

Product Compatibility FAQ

Q1: Can the IC695PBS301 operate in the same RX3i chassis as Ethernet and serial communication modules simultaneously?
Yes. The PACSystems RX3i Universal Backplane supports multiple communication modules in the same chassis. The IC695PBS301 can coexist with Ethernet modules such as the IC695ETM001 and serial communication modules, with each module independently managed by the CPU. This multi-protocol capability is fundamental to modern hybrid control architectures and requires no special configuration beyond standard module slot assignment in the Proficy Machine Edition programming environment.

Q2: What are the key compatibility and installation requirements when integrating the IC695PBS301 into an existing PROFIBUS DP network?
The IC695PBS301 requires a valid GSD (General Station Description) file to be loaded into the PROFIBUS DP master’s configuration tool. The module’s node address must be set uniquely within the network (1–125), and the PROFIBUS cable must be properly terminated at both physical ends of the segment. Baud rate is auto-detected from the master, so no manual baud rate configuration is required on the IC695PBS301 itself. Cable shielding must be grounded at one point to prevent ground loops, and the total cable length must comply with PROFIBUS DP distance specifications for the selected baud rate.

Q3: What does the warranty terms confirmed during quotation cover, and what long-term maintenance support is available for the IC695PBS301?
The warranty terms confirmed during quotation covers manufacturing defects and functional failures under normal operating conditions. ZYPLC provides pre-shipment testing of all IC695PBS301 units to verify PROFIBUS communication functionality, backplane interface integrity, and LED diagnostic indicator operation. For long-term maintenance, ZYPLC maintains inventory of IC695PBS301 modules to support spare parts programs, minimizing system downtime risk for facilities that depend on PACSystems RX3i architecture. Technical support for installation, configuration, and troubleshooting is available through our engineering team.