Skip to main content

GE

GE IS200EGDMH1AFG Ethernet Gateway for Mark VI

GE RFQ support for IS200EGDMH1AFG. Availability, condition, lead time, and export shipment options are confirmed before quote.

SKUIS200EGDMH1AFG BrandGE TypeEthernet Gateway Module SeriesMark VI OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Product identification and sourcing context

GE IS200EGDMH1AFG Ethernet Gateway for Mark VI is handled as a quote-based GE Speedtronic / Mark turbine-control spare part for turbine-control, DCS, PLC, and industrial maintenance projects. ZYPLC checks the full model number, board revision, installed platform, required condition, quantity, and destination country before quotation.

Brand GE
Model / SKU IS200EGDMH1AFG
Series context Mark VI
Part type Industrial Automation Spare Parts
RFQ basis Availability, condition, lead time, and export shipment options are confirmed before quote.

Where this part is typically used

This item is requested for gas turbine, steam turbine, generator excitation, protection, and plant control-system maintenance. GE Mark V, Mark VI, Mark VIe, and PACSystems installations often require exact board revision, firmware, terminal-board pairing, and rack context before a spare part can be safely sourced.

RFQ information for maintenance teams

  • Exact model number, revision suffix, and any board assembly code from the label.
  • Installed platform context such as Mark V, Mark VI, Mark VIe, Speedtronic, or PACSystems RX3i where applicable.
  • Quantity, urgency, required condition, and destination country.
  • Photos of front label, board barcode, connector area, or existing spare packaging.

Browse related GE spare parts, review the Mark VI series, or compare similar Industrial Automation Spare Parts records. If the exact revision is not shown, send the model and photos so the RFQ can be checked manually.

Request quote for this model

GE IS200EGDMH1AFG Ethernet Gateway for Mark VI Control System

The GE IS200EGDMH1AFG is a high-performance Ethernet Gateway Module engineered for seamless integration within the GE Mark VI Turbine Control System architecture. Designed to serve as the critical communication bridge between the control layer and the plant-wide network infrastructure, this module enables deterministic, high-speed data exchange across distributed control environments. Rather than functioning as a standalone component, the IS200EGDMH1AFG is conceived as a system-level asset — one that enhances overall architecture coherence, supports redundant communication pathways, and simplifies long-term maintenance across multi-tier automation platforms including GE’s Mark VI and EX2100 excitation control systems.

In modern industrial automation, the integrity of the communication layer is as critical as the control logic itself. The IS200EGDMH1AFG addresses this requirement by providing a robust Ethernet gateway function that connects the Mark VI’s internal IONet (I/O Network) to external Ethernet-based supervisory systems, historian servers, and HMI platforms. This system integration capability ensures that real-time turbine data — including speed, temperature, vibration, and flame detection signals — is accurately transmitted to higher-level SCADA and DCS layers without latency or data loss.

Product Specification Table

Parameter Specification
Part Number IS200EGDMH1AFG
Manufacturer GE (General Electric)
Series Mark VI Turbine Control System
Module Type Ethernet Gateway / Communication Module
System Role IONet-to-Ethernet Protocol Bridge
Communication Protocol Ethernet (IEEE 802.3), IONet (GE Proprietary)
Network Interface RJ-45 Ethernet Port
Operating Voltage 24 VDC (supplied via Mark VI backplane)
Operating Temperature 0°C to 60°C
Mounting Mark VI VME Rack / Backplane
Form Factor Single-slot VME board
Redundancy Support Dual-redundant communication path capable
Compatible Systems Mark VI, Mark VIe, EX2100 Excitation Control
Installation Environment Control cabinet, DIN-rail enclosure, turbine control panel
Warranty Warranty and support terms confirmed before quote

System Compatibility Notes

The IS200EGDMH1AFG does not operate in isolation — its value is fully realized when deployed within a complete Mark VI control system architecture. At the control layer, the module interfaces directly with the IS215UCVEH2A Mark VIe Controller Board, which serves as the primary CPU managing turbine sequencing, protection logic, and closed-loop control. The gateway module translates the controller’s internal IONet communications into standard Ethernet frames, enabling upstream connectivity to plant DCS platforms and historian systems.

On the I/O layer, the IS200EGDMH1AFG works in conjunction with I/O terminal boards such as the IS200TBAIH2BCD Analog Input Terminal Board and the IS200TBCIH1C Contact Input Terminal Board, which aggregate field signals from thermocouples, pressure transmitters, and discrete sensors. These signals are processed by the controller and then made available to the Ethernet gateway for transmission to supervisory systems. The gateway ensures that I/O data integrity is preserved across the network boundary, supporting accurate process visualization and alarm management at the HMI layer.

For power distribution, the Mark VI architecture relies on dedicated power supply modules such as the IS200EPCTG1A Power Controller Board, which conditions and distributes 24 VDC across the VME backplane. The IS200EGDMH1AFG draws its operating power from this backplane, ensuring that communication functions remain active even during partial system faults. This design supports the Mark VI’s inherent TMR (Triple Modular Redundancy) philosophy, where three independent control paths — each with its own gateway and I/O modules — vote on control outputs to eliminate single points of failure.

At the network layer, the IS200EGDMH1AFG connects to plant-wide Ethernet switches and routers, enabling integration with GE Proficy Historian servers and iFIX SCADA platforms. In redundant architectures, dual IS200EGDMH1AFG modules are deployed — one active, one standby — ensuring continuous data flow even during module replacement or network reconfiguration. This redundancy is further supported by the IS200EPDMG1B Ethernet Protection Module, which monitors gateway health and initiates automatic failover when communication anomalies are detected.

For human-machine interface integration, the gateway’s Ethernet output feeds directly into GE Cimplicity HMI workstations and operator panels, providing real-time turbine status, alarm annunciation, and trend data. In EX2100 excitation control applications, the IS200EGDMH1AFG similarly bridges the excitation controller’s internal bus to the plant DCS, enabling coordinated voltage regulation and reactive power management across the generator control architecture.

Industrial Application Notes

The IS200EGDMH1AFG finds application across a broad spectrum of industrial sectors where GE Mark VI turbine control systems are deployed. In power generation facilities — including gas turbine, steam turbine, and combined-cycle plants — the module serves as the communication backbone between the turbine control panel and the plant-wide maintenance planning system. Operators rely on the gateway’s real-time data transmission to monitor turbine performance, coordinate load dispatch, and respond to grid frequency events.

In petrochemical and refinery environments, the IS200EGDMH1AFG enables integration between GE turbine-driven compressor controls and the facility’s DCS platform, supporting coordinated process control across compression trains, heat exchangers, and separation units. The module’s robust Ethernet communication ensures that compressor surge protection data and vibration monitoring signals are continuously available to the process control layer.

In mining and metallurgical applications, where large electric motors and turbine-driven equipment operate under demanding conditions, the IS200EGDMH1AFG provides reliable communication between the Mark VI control system and the plant’s SCADA infrastructure. This connectivity supports predictive maintenance programs by enabling continuous transmission of equipment health data to historian and analytics platforms.

For water treatment and municipal utility operators, the gateway module facilitates integration between turbine-driven pump controls and the facility’s supervisory control system, supporting automated flow management, pressure regulation, and alarm response across distributed pump stations. The module’s Warranty and support terms confirmed before quote and proven field reliability make it a preferred choice for critical infrastructure applications where downtime carries significant operational and regulatory consequences.

Product Compatibility FAQ

Q1: Is the IS200EGDMH1AFG compatible with both Mark VI and Mark VIe control systems?
Yes. The IS200EGDMH1AFG is designed for use within the GE Mark VI VME-based architecture and is also compatible with Mark VIe systems when installed in the appropriate backplane configuration. For Mark VIe deployments, verify backplane slot assignments and IONet addressing with the system’s configuration tool (ToolboxST) to ensure proper module recognition and communication mapping. system integration with upstream DCS and historian platforms is supported in both architectures.

Q2: Can the IS200EGDMH1AFG be used in a redundant communication architecture, and what is required?
Yes. Redundant gateway configurations are supported by deploying two IS200EGDMH1AFG modules in designated redundant slots within the Mark VI rack. Each module connects to an independent Ethernet switch, providing dual communication paths to the plant network. Failover between active and standby gateways is managed by the Mark VI controller’s communication health monitoring logic. Ensure that both modules are configured with matching IONet node addresses and Ethernet IP parameters within ToolboxST to enable seamless failover without data interruption.

Q3: What does the Warranty and support terms confirmed before quote cover, and how is long-term maintenance supported?
The IS200EGDMH1AFG supplied by ZYPLC includes a Warranty and support terms confirmed before quote covering manufacturing defects, component failures, and functional non-conformance under normal operating conditions. Warranty service includes module replacement or repair, with technical support available throughout the warranty period. For long-term maintenance, ZYPLC supports RFQ-based sourcing of IS200EGDMH1AFG and related Mark VI modules, enabling rapid replacement to minimize turbine downtime. Customers are encouraged to maintain a spare module on-site as part of their critical spares program, particularly in single-gateway configurations where communication redundancy is not implemented.