Skip to main content

GE Grid Solutions

GE UR-4DH Industrial Network Interface for UR Series Systems

GE UR-4DH dual 100Mbps Ethernet module for UR Series relays. IEC 61850, Modbus TCP, DNP3. Real-time SCADA integration, warranty terms confirmed during quotation, global stock.

SKUUR 4DH BrandGE Grid Solutions TypeCommunication Module Seriesork Interface for UR Series OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The GE UR-4DH is a dual-port 100 Mbps Ethernet communication module engineered for the GE UR Series protection and control relay platform. Designed to serve as the critical network interface between field protection devices and upper-level control systems, the UR-4DH enables seamless, high-speed data exchange across substation automation networks, smart factory environments, and distributed control architectures. Whether integrating with SCADA platforms, engineering workstations, or remote monitoring centers, this module delivers the protocol versatility and network reliability demanded by modern industrial connectivity.

At the heart of the UR-4DH’s value is its support for IEC 61850, the international standard for substation communication, alongside Modbus TCP and DNP3 over TCP/IP. This multi-protocol capability allows the module to bridge legacy field devices and next-generation digital substations without requiring costly infrastructure overhauls. Engineers deploying GE UR6 or UR7 series relays — such as the GE L90 Line Differential Relay, GE T60 Transformer Protection Relay, or GE C60 Breaker Protection Relay — can leverage the UR-4DH to unify protection data, event records, and real-time measurements into a single, coherent network stream.

Compatibility & Integration Notes

Parameter Specification
SKU UR 4DH
Brand GE Grid Solutions
Series UR Series (UR6 / UR7 Platform)
Communication Protocols IEC 61850 (GOOSE / MMS), Modbus TCP, DNP3 over TCP/IP
Interface Type Dual-Port 100BASE-TX Ethernet (RJ-45)
Transmission Speed 100 Mbps Full Duplex
Network Compatibility TCP/IP, IEEE 802.3, Industrial Ethernet LAN/WAN
System Application Substation Automation, SCADA Integration, Protection Relay Networks, Smart Factory IIoT
Product Type Ethernet Communication Module
Origin United States
Warranty warranty terms confirmed during quotation
Availability RFQ Available — Global Shipping Available

Connected Automation Data Flow

In a typical smart substation or industrial automation deployment, the GE UR-4DH sits at the intersection of field-level protection and station-level control. Signal acquisition begins at the primary equipment — current transformers, voltage transformers, and digital inputs — feeding raw electrical data into the host UR Series relay. The UR-4DH then encapsulates this data into IEC 61850 MMS reports or GOOSE messages, transmitting them across the station LAN to the GE EnerVista UR Setup engineering workstation or directly to a SCADA gateway such as the GE D20MX Substation Controller.

Within the data flow chain, the UR-4DH works in concert with managed industrial Ethernet switches — for example, Hirschmann MACH104 or Moxa EDS-510A series switches — to maintain deterministic, low-latency communication across ring or star network topologies. For sites running mixed protocol environments, the module’s Modbus TCP port allows legacy HMI panels and GE iFIX SCADA or Wonderware System Platform to poll real-time analog values, status bits, and event logs without protocol conversion hardware.

Remote I/O expansion modules, such as the GE RIO-8 Remote I/O Module, can feed additional digital and analog signals into the UR relay chassis, with the UR-4DH aggregating all data streams and forwarding them upstream to the control center. For drive and motor protection applications, the UR-4DH enables the GE 469 Motor Management Relay and similar devices to share operational data — current draw, thermal state, fault history — with plant-level MES or ERP systems via DNP3 polling cycles. Edge gateways such as the GE MDS Orbit ECR can further extend this data to cloud-based analytics platforms, completing the IIoT data chain from sensor to enterprise.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial network modernization is the coexistence of incompatible communication protocols across different generations of equipment. Older protection relays may speak only Modbus RTU or proprietary serial protocols, while new digital substations demand IEC 61850 compliance. The GE UR-4DH directly addresses this fragmentation by providing a unified Ethernet gateway that speaks multiple protocols simultaneously, eliminating the need for standalone protocol converters and reducing single points of failure in the communication chain.

Data silos — where protection relay data, power quality measurements, and fault records exist in isolated systems — are broken down by the UR-4DH’s ability to publish structured data objects (SDOs) to any IEC 61850-compliant client on the network. SCADA operators gain real-time visibility into breaker status, differential current, and protection element pickups without manual data extraction. Remote diagnostics become practical: maintenance engineers can connect to the relay’s web interface or EnerVista software over the Ethernet port, retrieve oscillography files, and analyze fault events without dispatching field crews — a critical capability for unmanned substations and remote industrial sites.

Production line transparency is equally enhanced. By integrating UR Series relay data into plant SCADA or MES dashboards, operations teams can correlate electrical events with production interruptions, enabling root-cause analysis and predictive maintenance scheduling. System expansion is straightforward: additional UR Series relays can be added to the station LAN, each equipped with a UR-4DH module, and immediately discovered by the SCADA system through IEC 61850 server browsing — no manual IP configuration or protocol mapping required beyond initial commissioning.

Industrial Connectivity FAQ

Q1: What is the communication latency of the GE UR-4DH for GOOSE messaging?
The UR-4DH supports IEC 61850 GOOSE messaging with typical end-to-end latency well under 4 ms on a properly configured station LAN, meeting the performance requirements for protection interlocking and fast tripping applications in Class P2/P3 substation networks.

Q2: Is the UR-4DH compatible with third-party SCADA systems beyond GE platforms?
Yes. Because the UR-4DH implements open standards — IEC 61850, Modbus TCP, and DNP3 — it is compatible with any SCADA or DCS platform that supports these protocols, including Siemens SICAM, ABB MicroSCADA, Schneider Electric EcoStruxure, OSIsoft PI, and Ignition by Inductive Automation, among others.

Q3: How does the dual-port Ethernet design improve network reliability?
The dual-port configuration allows the UR-4DH to participate in redundant network topologies such as IEC 62439-3 PRP (Parallel Redundancy Protocol) or HSR (High-availability Seamless Redundancy), providing zero-switchover-time failover in the event of a single network path failure — essential for mission-critical protection and control applications.

Q4: What warranty and pre-shipment testing does the UR-4DH include?
Every GE UR-4DH unit supplied by ZYPLC undergoes pre-shipment functional testing covering Ethernet link establishment, protocol handshake verification, and communication integrity checks. All units are covered by a warranty terms confirmed during quotation from the date of shipment, with global logistics support and expedited delivery options available for urgent project requirements.

—