Skip to main content

Omron

Omron C200H-ID217 Digital Input for C200H

Omron C200H-ID217 digital input module for C200H PLC systems. warranty terms confirmed during quotation. RFQ compatibility review with C200H backplane, CPU, and I/O architecture.

SKUC200H-ID217 BrandOmron TypeDigital Input Module SeriesC200H OriginJP CategorySensors & I/O
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Omron C200H-ID217 Digital Input for C200H

The Omron C200H-ID217 is a 32-point DC digital input module engineered for seamless integration within the C200H modular PLC platform. Rather than functioning as a standalone component, the C200H-ID217 is designed to operate as a precision signal acquisition layer within a structured, multi-tier control architecture — collecting field-level discrete signals and delivering them reliably to the CPU for real-time processing. Understanding its role within the broader system is essential for engineers designing scalable, maintainable, and redundancy-capable automation solutions.

In a complete C200H control system, the C200H-ID217 occupies the I/O layer, interfacing directly with field devices such as proximity sensors, limit switches, push buttons, and photoelectric sensors. Its 24 VDC input compatibility and high-density 32-point configuration make it a preferred choice for applications where panel space is limited and signal density is high. The module slots into the C200H-BC081 or C200H-BC051 backplane, sharing the internal I/O bus with other expansion modules and communicating upstream to the CPU unit — such as the C200H-CPU21 or C200H-CPU31 — through the rack’s integrated data highway.

Product Specification Table

Parameter Specification
System Role 32-Point DC Digital Input Module — I/O Layer
Input Points 32 points (2 × 16-point groups)
Input Voltage 24 VDC (12–24 VDC range)
Input Current Approx. 7 mA at 24 VDC
ON Voltage 14.4 VDC min
OFF Voltage 5.0 VDC max
Response Time 1.5 ms max (ON/OFF)
Isolation Photocoupler isolation
Connector Type 40-pin MIL connector
Compatible Backplanes C200H-BC081, C200H-BC051, C200H-BC031
Compatible CPUs C200H-CPU21, C200H-CPU31, C200HS-CPU01
Communication C200H internal I/O bus (rack-based)
Installation Environment 0–55°C, 10–90% RH (non-condensing), IP20
Power Consumption 0.26 A at 5 VDC (from backplane)
Warranty warranty terms confirmed during quotation — tested, verified, ready to deploy

System Compatibility Notes

The C200H-ID217 achieves its full potential when deployed within a coordinated C200H system architecture. At the processing core, the C200H-CPU21 or C200H-CPU31 CPU module executes the ladder logic program, scanning all I/O modules on the rack at each cycle. The C200H-ID217 feeds discrete input states directly into this scan cycle, enabling the CPU to make real-time control decisions based on field conditions.

Power integrity across the rack is maintained by the C200H-PS221 power supply unit, which provides regulated 5 VDC and 24 VDC rails to all installed modules including the C200H-ID217. Stable power delivery is critical for consistent input signal recognition, particularly in electrically noisy industrial environments such as motor control centers or high-frequency switching panels.

On the output side, the C200H-OD218 transistor output module and C200H-OC225 relay output module work in tandem with the C200H-ID217 to complete the input-to-output signal chain. While the C200H-ID217 captures field signals, the output modules drive actuators, solenoids, and contactors based on the CPU’s processed logic — forming a closed-loop control layer within the rack.

For analog process variables, the C200H-AD002 analog input module and C200H-DA002 analog output module complement the digital I/O layer, enabling hybrid architectures that handle both discrete and continuous signals within the same backplane. Temperature control loops, for example, can be managed by the C200H-TC101 temperature control unit, which integrates directly into the C200H rack alongside the C200H-ID217.

Network connectivity and remote I/O expansion are handled by the C200HW-COM06 communications module, which supports Host Link and RS-232C protocols for SCADA integration, HMI connectivity, and inter-PLC communication. At the human-machine interface layer, the NS8-TV00B-V2 touchscreen HMI connects to the C200H system via serial or Ethernet, providing operators with real-time visibility into the input states captured by the C200H-ID217 and the overall system status.

This coordinated architecture — spanning CPU, power supply, digital I/O, analog I/O, communications, and HMI — demonstrates how the C200H-ID217 functions not as an isolated component but as an integral node in a structured, layered control system. Proper module selection, backplane configuration, and rack addressing ensure that the C200H-ID217 contributes to system consistency, expandability, and long-term maintainability.

Industrial Application Notes

The C200H-ID217 has been widely deployed across a broad spectrum of industrial automation environments, each demanding reliable discrete signal acquisition within a structured control hierarchy.

In manufacturing and assembly lines, the module captures position feedback from limit switches and part-present sensors, enabling the C200H CPU to sequence robotic arms, conveyor drives, and pneumatic actuators with precise timing. Its 1.5 ms response time ensures that high-speed production lines maintain synchronization without signal lag.

In power distribution and electrical substations, the C200H-ID217 monitors breaker status, relay feedback, and interlock conditions, feeding critical binary states to the control CPU for protection logic execution. Its photocoupler isolation provides the electrical separation required in high-voltage environments.

In petrochemical and refinery process control, the module integrates with field junction boxes to collect valve position feedback, pump run signals, and emergency shutdown (ESD) inputs. The C200H system’s modular architecture allows engineers to expand I/O capacity by adding additional C200H-ID217 modules to the backplane without modifying the existing control program structure.

In water treatment and municipal utilities, the C200H-ID217 monitors level switches, flow confirmation signals, and pump status across distributed pump stations, with data aggregated at the C200H CPU and transmitted upstream via the C200HW-COM06 communications module to a central SCADA system.

In mining, metallurgy, and heavy industry, the module’s robust operating temperature range and vibration tolerance make it suitable for installation in field control panels close to crushers, conveyors, and hoisting equipment, where environmental conditions are demanding and signal reliability is non-negotiable.

Product Compatibility FAQ

Q1: Is the C200H-ID217 compatible with all C200H backplanes, and how many modules can be installed per rack?
The C200H-ID217 is compatible with the C200H-BC081 (8-slot), C200H-BC051 (5-slot), and C200H-BC031 (3-slot) backplanes. Each slot accommodates one I/O module, and the total number of I/O points per CPU is determined by the CPU model — the C200H-CPU21 supports up to 512 I/O points, allowing multiple C200H-ID217 modules to be installed across expansion racks connected via the C200H expansion I/O cable. Rack addressing must be configured correctly to avoid I/O word conflicts.

Q2: How does the C200H-ID217 integrate into a system with both local and remote I/O expansion?
In architectures requiring remote I/O, the C200H-ID217 can be installed in remote expansion racks connected to the master CPU rack via the C200H remote I/O system. The C200HW-COM06 or dedicated remote I/O master/slave units manage the communication link, ensuring that input states from remote C200H-ID217 modules are scanned within the CPU’s I/O refresh cycle. This architecture supports geographically distributed control panels while maintaining centralized logic execution — a common requirement in large-scale process plants and utility facilities.

Q3: What does the warranty terms confirmed during quotation cover, and how is long-term maintenance supported?
Every C200H-ID217 supplied by ZYPLC is covered by a warranty terms confirmed during quotation against manufacturing defects and functional failures under normal operating conditions. Prior to shipment, each module undergoes functional verification testing to confirm input response, isolation integrity, and bus communication. For long-term maintenance, ZYPLC supports RFQ sourcing for C200H-series modules to support planned replacements, emergency spares, and system expansions — reducing the risk of production downtime caused by obsolete component shortages. Our technical team is available to assist with system compatibility verification, rack configuration review, and installation guidance.