Phoenix Contact TRIO-PS/1AC/48DC/5 (2866491) 48VDC 5A DIN-rail industrial power supply. TRIO Series, protocol-ready, warranty terms confirmed during quotation, export shipping options available.

SKUTRIO-PS/1AC/48DC/5 2866491 BrandPhoenix Contact TypeIndustrial Power Supply SeriesTRIO Series OriginDE CategoryDrives & Motors
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Phoenix Contact TRIO-PS/1AC/48DC/5 (Order No. 2866491) is a high-reliability DIN-rail mounted industrial power supply delivering a stable 48 VDC / 5 A output from a single-phase AC input. Engineered for demanding industrial environments, this TRIO Series unit serves as the foundational power backbone for field devices, communication gateways, remote I/O modules, and edge computing nodes across modern smart factory architectures. Where data integrity depends on uninterrupted power, the TRIO-PS/1AC/48DC/5 ensures that every node in the automation network remains energized, synchronized, and ready to transmit.

In today’s converged OT/IT environments, stable DC power is not merely a utility — it is a prerequisite for deterministic communication. Whether powering a Phoenix Contact FL SWITCH 2008 managed industrial Ethernet switch, a QUINT-PS series redundancy module, or a RAD-2400-IFS wireless gateway, the TRIO-PS/1AC/48DC/5 provides the clean, regulated 48 VDC rail that keeps protocol stacks — including PROFINET, EtherNet/IP, Modbus TCP, and OPC UA — operating without voltage-induced packet loss or communication timeouts.

Compatibility & Integration Notes

Parameter Specification
SKU / Order No. TRIO-PS/1AC/48DC/5 / 2866491
Brand / Series Phoenix Contact / TRIO
Input Voltage 85–264 VAC, 1-phase (universal input)
Output Voltage 48 VDC (adjustable)
Output Current 5 A
Output Power 240 W
Mounting DIN rail (EN 60715 TH 35)
Protection Class IP20
Protocol Compatibility Powers PROFINET, EtherNet/IP, Modbus TCP, OPC UA, HART gateway nodes
Interface Support Powers Ethernet switches, serial gateways, remote I/O, HMI panels
Network Architecture Compatible with ring, star, and linear Ethernet topologies
System Application PLC control panels, SCADA power rails, field junction boxes, edge nodes
Origin Germany
Warranty 12 Months

Connected Automation Data Flow

In a typical smart factory deployment, the TRIO-PS/1AC/48DC/5 (2866491) sits at the heart of the control cabinet power rail, supplying stable 48 VDC to a cascade of interconnected automation components. The data flow begins at the field level, where Phoenix Contact NLC S3 compact PLCs and AXC F 2152 AXILine controllers collect real-time process values from pressure transmitters, flow sensors, and temperature probes. These field signals are digitized and passed upstream via Axioline F remote I/O modules, which rely on a clean, ripple-free DC supply to maintain sub-millisecond cycle times on the PROFINET ring.

As data moves from the field bus to the plant network, Phoenix Contact FL SWITCH 2016 managed Ethernet switches — powered from the same 48 VDC rail — enforce VLAN segmentation and Quality of Service (QoS) prioritization, ensuring that time-critical PROFINET frames are never delayed by bulk data transfers. Protocol conversion between legacy serial devices and modern Ethernet-based SCADA systems is handled by Phoenix Contact GW PL ETH/BASIC-BUS gateways, which translate Modbus RTU signals from older variable frequency drives and motor starters into Modbus TCP packets readable by the plant’s WinCC SCADA or Ignition supervisory platform.

At the HMI layer, Phoenix Contact TP 3121T touch panels display live process data, alarm states, and trend graphs drawn directly from the OPC UA server running on the AXC F controller. The 48 VDC supply from the TRIO-PS/1AC/48DC/5 powers the panel’s backlight and communication interface simultaneously, eliminating the need for a separate 24 VDC converter in space-constrained enclosures. Meanwhile, RAD-900-IFS wireless I/O modules extend the network to remote field stations — tank farms, outdoor pump skids, or conveyor endpoints — where running Ethernet cable is impractical, transmitting sensor data back to the control room over licensed 900 MHz radio links.

Edge intelligence is added through Phoenix Contact PLCnext Control AXC F 3152 edge gateways, which aggregate OPC UA data streams, apply local analytics, and push structured JSON payloads to cloud-based MES or ERP platforms via MQTT over TLS. The entire data chain — from raw sensor signal to cloud dashboard — depends on the uninterrupted, stable 48 VDC output of the TRIO-PS/1AC/48DC/5 to maintain communication integrity at every node.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the coexistence of multiple communication protocols across different generations of equipment. A single production line may simultaneously run PROFIBUS DP on legacy servo drives, EtherNet/IP on newer robot controllers, and Modbus RTU on older energy meters — creating data silos that prevent plant-wide visibility. The TRIO-PS/1AC/48DC/5 addresses this challenge indirectly but critically: by providing a stable, noise-free 48 VDC power source, it ensures that protocol gateways and media converters operate within their specified voltage tolerances, eliminating the power-related communication errors that are frequently misdiagnosed as software or firmware issues.

Remote monitoring and predictive maintenance require continuous, uninterrupted data streams. A voltage sag or ripple on the DC bus can cause a PROFINET controller to drop its cyclic communication, triggering a false alarm in the SCADA system and forcing an unnecessary production stop. The TRIO Series power supply’s active power factor correction and wide-range input (85–264 VAC) make it immune to the voltage fluctuations common in industrial facilities with heavy motor loads, welding equipment, or shared utility feeds. This translates directly into higher network uptime, fewer nuisance trips, and more reliable remote diagnostics.

For system integrators planning future expansion, the TRIO-PS/1AC/48DC/5’s DIN-rail form factor and standard terminal block connections simplify the addition of new network nodes — additional remote I/O racks, new HMI stations, or supplementary wireless access points — without requiring panel redesign. The 48 VDC output is also compatible with a growing range of industrial PoE++ switches and IP cameras used in vision-guided assembly and quality inspection systems, making this power supply a forward-compatible choice for Industry 4.0 upgrades.

Industrial Connectivity FAQ

Q1: Does the TRIO-PS/1AC/48DC/5 (2866491) support powering PROFINET and EtherNet/IP network components simultaneously?
Yes. The 48 VDC / 5 A output (240 W total) is sufficient to power multiple managed Ethernet switches, protocol gateways, and remote I/O modules on a shared DC bus. PROFINET and EtherNet/IP devices operate on the network layer above the power supply, so both protocols can coexist on the same powered infrastructure without interference.

Q2: How does supply voltage stability affect communication latency in PROFINET or Modbus TCP networks?
Voltage ripple or sags on the DC bus can cause network interface cards in PLCs, switches, and gateways to reset or retransmit packets, adding latency and jitter to otherwise deterministic networks. The TRIO-PS/1AC/48DC/5 maintains output ripple below 50 mV peak-to-peak, well within the tolerance of all major industrial Ethernet controllers, ensuring sub-millisecond cycle times are preserved.

Q3: Can this power supply be used in systems that require network redundancy or ring topology (e.g., PROFINET MRP)?
Absolutely. The TRIO-PS/1AC/48DC/5 is fully compatible with redundant power architectures. When paired with a Phoenix Contact QUINT-ORING redundancy module, two TRIO units can be configured in a 1+1 redundant arrangement, ensuring that a single power supply failure does not interrupt the PROFINET MRP ring or any other network topology dependent on continuous DC power.

Q4: What warranty and pre-shipment testing does this unit include?
Every TRIO-PS/1AC/48DC/5 (2866491) supplied by ZYPLC carries a warranty terms confirmed during quotation covering manufacturing defects and functional failures. Units undergo pre-shipment functional testing — including output voltage verification, load regulation check, and input range validation — before dispatch. RFQ responses are provided within 24 hours, and global shipping is available with full tracking.