Skip to main content

Schneider Electric

Schneider Electric 171CCC76010 Industrial Network Interface for Momentum Systems

Schneider Electric 171CCC76010 Ethernet TCP/IP Gateway for Momentum PLC. Protocol conversion, SCADA integration, warranty terms confirmed during quotation. RFQ at zyplc.com.

SKU171CCC76010 BrandSchneider Electric TypeIndustrial Communication Adapter SeriesMomentum OriginFR CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Schneider Electric 171CCC76010 is a high-performance Ethernet TCP/IP Communication Adapter engineered for the Momentum Series PLC platform. Designed to serve as the critical network interface between field-level devices and upper-level control systems, the 171CCC76010 enables seamless, real-time data exchange across the entire automation hierarchy — from sensor signals and remote I/O modules to SCADA servers and MES platforms. In smart factory environments where data latency, protocol fragmentation, and network instability can directly impact production efficiency, this adapter delivers the industrial-grade connectivity that modern facilities demand.

Compatibility & Integration Notes

Parameter Specification
SKU / Part Number 171CCC76010
Brand Schneider Electric
Series Momentum
Communication Protocol Ethernet TCP/IP (Modbus TCP)
Interface Type RJ45 Ethernet Port
Transmission Speed 10/100 Mbps
Network Compatibility Modbus TCP/IP, EtherNet/IP, Industrial Ethernet
System Application PLC, SCADA, HMI, Remote I/O, DCS Integration
Product Type Industrial Communication Adapter / Network Gateway
Origin France
Warranty 12 Months
Stock Status Available — Ships Globally

Connected Automation Data Flow

In a typical smart factory deployment, the 171CCC76010 sits at the heart of the communication architecture, bridging the Momentum M1E CPU module with the plant-wide Ethernet backbone. Signal acquisition begins at the field level, where distributed sensors — including temperature transmitters, pressure transducers, and proximity switches — feed data into Momentum Remote I/O adapters such as the 170ADI34000 digital input module and 170AAO92100 analog output module. These I/O modules communicate upstream to the Momentum CPU via the adapter’s Modbus TCP/IP protocol stack, ensuring deterministic, low-latency data delivery.

At the controller level, the 171CCC76010 interfaces directly with the Momentum M1E processor (171CCS76020), enabling the PLC to publish real-time process variables to the Ethernet network. This data is then consumed by Vijeo Citect SCADA or Wonderware InTouch HMI stations, which provide operators with live dashboards, trend analysis, and alarm management. The adapter’s support for standard Modbus TCP/IP ensures compatibility with a broad ecosystem of SCADA clients without requiring proprietary middleware or protocol converters.

For drive integration, the 171CCC76010 supports network-level communication with Schneider Electric Altivar ATV320 and ATV630 variable frequency drives, allowing speed references, torque commands, and fault diagnostics to be exchanged over the same Ethernet segment. This eliminates the need for dedicated serial links and simplifies the overall network topology. Similarly, Modicon M340 PLCs deployed in adjacent production cells can exchange data with the Momentum platform via standard Modbus TCP/IP peer-to-peer communication, enabling coordinated multi-controller automation without a central gateway bottleneck.

At the edge layer, the 171CCC76010 can feed process data into Schneider Electric EcoStruxure Machine Advisor or third-party edge gateways for cloud-based analytics, predictive maintenance, and OEE monitoring. This positions the adapter as a foundational component in IIoT-ready architectures, where legacy Momentum hardware is extended into modern digital factory platforms without costly infrastructure replacement.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the coexistence of multiple communication protocols across different generations of equipment. Older field devices may speak Modbus RTU over RS-485, while newer PLCs and HMIs operate exclusively on Ethernet TCP/IP networks. Without a capable network interface like the 171CCC76010, these systems remain isolated — unable to share data, synchronize operations, or participate in plant-wide monitoring.

The 171CCC76010 resolves this by acting as the Ethernet gateway for the Momentum platform, translating field-level Modbus RTU signals into Modbus TCP/IP packets that can traverse standard IT/OT network infrastructure. This protocol unification eliminates data silos, allowing production data from every connected device — drives, sensors, remote I/O, and safety modules — to flow into a single, unified SCADA or MES database.

Remote monitoring and diagnostics are equally critical in modern facilities. With the 171CCC76010 in place, maintenance engineers can access real-time device status, fault codes, and performance metrics from any networked workstation or remote terminal — without physically visiting the control panel. This capability dramatically reduces mean time to repair (MTTR) and supports proactive maintenance strategies that minimize unplanned downtime.

System scalability is another key advantage. As production lines expand, additional Momentum I/O modules and remote stations can be added to the network without redesigning the communication architecture. The adapter’s standard Ethernet interface ensures that new devices integrate seamlessly into the existing topology, protecting the long-term value of the automation investment.

Every 171CCC76010 unit supplied by ZYPLC undergoes pre-shipment functional testing to verify communication integrity, network handshake performance, and protocol compliance. Units are shipped with full documentation and are backed by a warranty terms confirmed during quotation, with availability confirmed by RFQ availability for shipment arranged after confirmation.

Industrial Connectivity FAQ

Q1: What is the communication latency of the 171CCC76010 on a Modbus TCP/IP network?
The 171CCC76010 supports standard Modbus TCP/IP with typical cycle times in the range of 1–10 ms depending on network load and the number of connected nodes. For time-critical applications, it is recommended to segment the automation network using managed industrial switches to minimize broadcast traffic and ensure deterministic response times.

Q2: Is the 171CCC76010 compatible with third-party SCADA and HMI systems beyond Schneider Electric’s own software?
Yes. Because the 171CCC76010 uses standard Modbus TCP/IP — an open, widely adopted industrial protocol — it is compatible with virtually all major SCADA and HMI platforms, including Ignition by Inductive Automation, Wonderware System Platform, Siemens WinCC, and GE iFIX. No proprietary drivers are required for basic Modbus TCP/IP communication.

Q3: Can the 171CCC76010 be used to expand an existing Momentum system with additional I/O modules?
Absolutely. The adapter is designed to support network-based expansion of the Momentum platform. Additional remote I/O bases and modules can be connected to the same Ethernet segment, and the adapter will manage data routing between the CPU and all connected I/O stations. This makes it straightforward to scale the system as production requirements grow.

Q4: What warranty and testing standards apply to 171CCC76010 units from ZYPLC?
All 171CCC76010 units are covered by a warranty terms confirmed during quotation from the date of shipment. Prior to dispatch, each unit undergoes pre-shipment functional testing including power-on verification, Ethernet link establishment, and Modbus TCP/IP communication handshake testing. Units are supplied with original packaging and documentation where available. For RFQ, lead time, and technical support, contact ZYPLC directly.