Schneider Electric
Schneider GV2-ME10C Industrial Network Interface for GV2-ME Systems
Schneider GV2-ME10C 4-6.3A motor circuit breaker with 12-Month Warranty. Contextual Integration in GV2-ME Series smart factory networks. In stock, fast ship.
Schneider Electric
Schneider GV2-ME10C 4-6.3A motor circuit breaker with 12-Month Warranty. Contextual Integration in GV2-ME Series smart factory networks. In stock, fast ship.
In modern industrial environments, the ability to connect field-level protection devices into a unified data network is no longer optional — it is the foundation of operational transparency, predictive maintenance, and system-wide efficiency. The Schneider Electric GV2-ME10C, a 4–6.3 A motor circuit breaker from the GV2-ME Series, occupies a critical position in this connectivity chain. Far beyond its role as a standalone protective device, the GV2-ME10C serves as a network-ready node within layered automation architectures, enabling real-time status feedback, remote diagnostics, and seamless integration with SCADA, HMI, and PLC control platforms.
The GV2-ME Series was engineered by Schneider Electric to meet the demands of smart factory deployments where every device must contribute to the data flow — from signal acquisition at the motor terminal to alarm escalation at the supervisory level. The GV2-ME10C fits precisely into this model, offering compact DIN-rail installation, thermal-magnetic protection, and compatibility with Schneider’s TeSys communication accessories that extend its connectivity into Modbus, CANopen, and AS-Interface networks.
| Parameter | Specification |
|---|---|
| SKU | GV2-ME10C |
| Brand | Schneider Electric |
| Series | GV2-ME (TeSys) |
| Product Type | Motor Circuit Breaker |
| Current Rating | 4–6.3 A |
| Tripping Class | Class 10 (Thermal-Magnetic) |
| Poles | 3-Pole |
| Voltage Rating | 690 V AC (IEC), 600 V AC (UL) |
| Breaking Capacity | 50 kA at 415 V AC |
| Communication Compatibility | Modbus RTU, CANopen, AS-Interface (via GV2-G / GVAD accessories) |
| Network Interface Accessories | GV2-G, GVAD1210, LU9GC3 communication modules |
| Mounting | DIN Rail / Panel Mount |
| Protection Degree | IP20 (base unit) |
| Operating Temperature | -25°C to +60°C |
| Origin | France |
| Warranty | 12-Month Warranty |
The GV2-ME10C does not operate in isolation. In a typical smart factory deployment, it is installed within a motor control center (MCC) or distribution panel alongside Schneider Electric’s TeSys D LC1D contactor series — most commonly the LC1D09 or LC1D12 — forming a coordinated starter assembly. The contactor handles switching commands issued by the upstream PLC, while the GV2-ME10C provides overload and short-circuit protection, with its trip status fed back into the control loop.
At the control layer, a Schneider Modicon M221 PLC or Modicon M340 processes the motor status signals. When the GV2-ME10C is paired with a GV2-G communication gateway module, its trip status, current draw, and fault codes are transmitted over Modbus RTU directly to the PLC’s communication port, eliminating the need for discrete wiring of auxiliary contacts. This reduces panel wiring complexity and accelerates fault diagnosis during commissioning and maintenance cycles.
For facilities running AS-Interface networks, the GVAD1210 AS-Interface adapter connects the GV2-ME10C into the AS-i bus, allowing the Schneider ABE7H16R21 remote I/O module or a dedicated AS-i master card installed in the Modicon rack to poll device status cyclically. This architecture supports up to 62 slave nodes on a single AS-i segment, making it highly scalable for large motor-driven production lines in packaging, water treatment, and HVAC applications.
At the supervisory level, Schneider EcoStruxure Operator Terminal Expert (formerly Vijeo Designer) running on a HMIGTO5310 HMI panel displays real-time motor status, trip history, and energy consumption data aggregated from multiple GV2-ME10C units across the network. SCADA systems such as Schneider EcoStruxure SCADA Expert (ClearSCADA) can subscribe to these data points via OPC-UA or Modbus TCP gateways, enabling plant-wide visibility and alarm management from a centralized control room.
Power distribution to the motor control assemblies is typically managed through Schneider Acti9 iC60N circuit breakers at the panel feeder level, ensuring coordinated protection from the main distribution board down to the individual motor branch. The GV2-ME10C’s selectivity with upstream Acti9 devices is pre-validated in Schneider’s EcoStruxure Power Design tool, simplifying engineering documentation and approval workflows.
For edge connectivity and IIoT integration, a Schneider EcoStruxure Machine Advisor gateway or a third-party industrial edge gateway running MQTT or REST APIs can aggregate Modbus data from multiple GV2-ME10C nodes and push it to cloud analytics platforms, enabling predictive maintenance models based on thermal trip frequency and current trend analysis.
One of the most persistent challenges in industrial facilities is the fragmentation of device data — motors, drives, and protection devices that operate without any network connectivity, leaving maintenance teams dependent on manual inspection and reactive fault response. The GV2-ME10C, when deployed with its communication accessories, directly addresses this data isolation problem.
In facilities where different generations of equipment coexist — older relay-based starters alongside modern variable frequency drives such as the Schneider Altivar ATV312 or ATV630 — the GV2-ME10C’s Modbus RTU compatibility allows it to share the same communication bus as the drives, creating a unified data layer without requiring a full system replacement. Protocol conversion gateways can further bridge this data to Ethernet/IP or PROFINET networks used by newer PLC platforms, ensuring backward compatibility while enabling forward-looking smart factory initiatives.
Remote monitoring becomes particularly valuable in unmanned substations, pump stations, and compressor rooms where physical access is limited. With the GV2-ME10C integrated into the Modbus network, operators can remotely verify motor protection status, acknowledge trip events, and schedule maintenance windows based on actual device data rather than fixed time intervals — reducing unplanned downtime and extending equipment service life.
Production line transparency is another key benefit. In multi-motor conveyor systems or packaging lines, each GV2-ME10C unit reports its status independently, allowing SCADA operators to pinpoint the exact motor that tripped, view the fault type (overload vs. short-circuit), and dispatch maintenance personnel with the correct replacement parts — all before the line restart sequence begins. This level of diagnostic granularity is only possible when field protection devices are fully integrated into the plant’s data network.
Q1: Does the GV2-ME10C support direct Ethernet or Modbus TCP communication?
The GV2-ME10C base unit does not include a built-in Ethernet port. However, it supports Modbus RTU and AS-Interface communication when paired with Schneider’s GV2-G or GVAD accessory modules. For Modbus TCP or Ethernet/IP connectivity, a protocol conversion gateway such as the Schneider EGX150 or a third-party Modbus RTU-to-TCP converter can be used to bridge the GV2-ME10C data onto an Ethernet network.
Q2: Is the GV2-ME10C compatible with Schneider’s EcoStruxure architecture and TeSys Island platform?
The GV2-ME10C is fully compatible with Schneider’s EcoStruxure architecture when used with the appropriate communication accessories. While the newer TeSys Island platform offers native Ethernet connectivity, the GV2-ME10C integrates into EcoStruxure via Modbus RTU gateways and AS-Interface masters, making it suitable for both legacy upgrades and new installations where cost-effective motor protection with network visibility is required.
Q3: What is the delivery lead time and warranty coverage for the GV2-ME10C?
In-stock units are typically dispatched within 1–3 business days via DHL or FedEx international express. Each GV2-ME10C supplied by ZYPLC is covered by a 12-Month Warranty against manufacturing defects, with pre-shipment functional testing performed on every unit. RFQ responses are provided within 24 hours for volume orders.
Q4: Can the GV2-ME10C be used in systems with variable frequency drives (VFDs) on the same network?
Yes. In motor control architectures where Schneider Altivar ATV312 or ATV630 drives share a Modbus RTU network with the GV2-ME10C (via communication accessories), both device types can coexist on the same RS-485 bus with unique node addresses. The PLC or SCADA system polls each device independently, enabling coordinated motor management — including soft-start sequencing, overload monitoring, and fault logging — across the entire drive and protection layer.