Skip to main content

Schneider Electric

Schneider INMC-3402230500 Industrial Network Interface for Altivar Systems

Schneider INMC-3402230500 Ethernet/IP & Modbus TCP communication module for Altivar drives. Industrial gateway, warranty terms confirmed during quotation, global shipping. RFQ now.

SKU3402230500 34003816XD-1DA 34003816XD-6DA 0006230138B3 BrandSchneider Electric TypeIndustrial Communication Module SeriesAltivar OriginFR CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

In modern smart factory environments, seamless data flow between field devices and upper-level control systems is no longer optional — it is the backbone of operational efficiency. The Schneider Electric INMC-3402230500 Ethernet communication module is engineered precisely for this mission: delivering reliable, high-speed protocol conversion and network connectivity for Altivar variable frequency drives within complex industrial automation architectures.

Whether your facility runs a distributed SCADA platform, a multi-node PLC network, or a hybrid HMI-driven production line, the INMC-3402230500 acts as the critical communication bridge that eliminates data silos and enables real-time visibility across every layer of your automation pyramid.

Compatibility & Integration Notes

Parameter Specification
SKU / Part Number INMC-3402230500 (Alt: 34003816XD-1DA, 34003816XD-6DA, 0006230138B3)
Brand Schneider Electric
Compatible Series Altivar ATV312, ATV320, ATV340, ATV630, ATV650, ATV930
Communication Protocols Ethernet/IP, Modbus TCP/IP
Interface Type RJ45 Ethernet Port
Transmission Speed 10/100 Mbps Auto-negotiation
Network Compatibility Industrial Ethernet, TCP/IP, EtherNet/IP CIP
System Applications SCADA, HMI, PLC, DCS, Remote I/O, MES Integration
Mounting Direct plug-in to Altivar drive option slot
Origin Germany (DE)
Warranty warranty terms confirmed during quotation
Shipping DHL / FedEx Global Express

Connected Automation Data Flow

The INMC-3402230500 sits at the heart of a layered industrial communication architecture. At the field level, Altivar ATV630 and ATV930 variable frequency drives control motor loads — pumps, compressors, conveyors — and generate continuous operational data: speed references, output frequency, motor current, fault codes, and thermal status. Without a capable communication interface, this data remains locked inside the drive.

Once the INMC-3402230500 is installed in the Altivar option slot, it immediately opens an Ethernet/IP and Modbus TCP channel, allowing a Modicon M340 or Modicon M580 PLC to poll drive parameters cyclically at sub-100ms intervals. The PLC logic can then issue speed commands, enable/disable outputs, and read back real-time feedback — all over a single RJ45 connection integrated into the plant’s existing industrial Ethernet backbone.

Upstream, a Wonderware System Platform or Vijeo Citect SCADA server subscribes to the drive data via the PLC’s Ethernet/IP scanner, building live process dashboards and historian trends. Operators at Magelis GTU HMI terminals on the production floor can monitor drive status, acknowledge alarms, and adjust setpoints without leaving the line — all because the INMC-3402230500 has made the Altivar drive a fully addressable node on the network.

For remote I/O expansion, the INMC-3402230500 works alongside Advantys STB distributed I/O islands, which share the same Ethernet/IP segment. A ConneXium Industrial Ethernet Switch (e.g., TCSESM083F23F0) manages traffic prioritization across drives, I/O nodes, and controller uplinks, ensuring deterministic communication even under heavy network load.

At the edge, an EcoStruxure Machine Advisor edge gateway can aggregate data from multiple INMC-equipped drives, forwarding normalized datasets to cloud analytics platforms for predictive maintenance scoring, energy benchmarking, and OEE reporting. This end-to-end data chain — from motor shaft to cloud dashboard — is made possible by the INMC-3402230500’s role as the protocol gateway at the drive level.

In multi-drive applications, such as a water treatment station running five ATV320 drives on a Modbus TCP ring, the INMC-3402230500 modules allow a single Modicon TM251 controller to address all drives sequentially, read flow and pressure sensor feedback via Advantys OTB remote I/O, and trigger alarm outputs through a Zelio Logic smart relay — all within a unified Ethernet/IP network segment.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in legacy industrial environments is protocol fragmentation. A plant may run Modbus RTU on older drives, PROFIBUS on legacy sensors, and proprietary serial links on aging HMI panels — creating islands of data that cannot communicate with each other or with modern MES and ERP systems.

The INMC-3402230500 directly addresses this by converting the Altivar drive’s internal communication into standard Ethernet/IP and Modbus TCP — the two most widely supported industrial Ethernet protocols in global automation. This means existing PLC programs written for Modicon, Allen-Bradley, or Siemens controllers can address the Altivar drive using native function blocks, without custom drivers or middleware.

For remote monitoring, the module enables SCADA systems to reach drives installed in remote pump stations, substations, or outdoor enclosures over standard TCP/IP infrastructure — including fiber optic Ethernet and industrial wireless bridges. Maintenance engineers can diagnose drive faults, review trip histories, and adjust parameters from a central control room or even a mobile device, dramatically reducing unplanned downtime and travel costs.

Production line transparency is another key benefit. With every Altivar drive reporting real-time data to the SCADA historian, production managers gain granular visibility into operating load per motor, cycle times per conveyor zone, and fault frequency per drive — enabling data-driven decisions on maintenance scheduling, maintenance planning, and capacity planning.

System expansion is equally straightforward. Adding a new Altivar drive to an existing network requires only plugging in an INMC-3402230500, assigning an IP address, and configuring the PLC scanner — no new cabling infrastructure, no protocol converters, no additional gateways. This plug-and-play scalability makes the INMC-3402230500 the preferred communication solution for phased factory upgrades and greenfield smart factory builds alike.

Every unit shipped by ZYPLC undergoes pre-shipment functional testing, verifying Ethernet link establishment, protocol handshake, and parameter read/write integrity before dispatch. Combined with a warranty terms confirmed during quotation and global DHL/FedEx express delivery, customers receive a fully verified, ready-to-install communication module with full after-sales support.

Industrial Connectivity FAQ

Q1: What is the communication latency of the INMC-3402230500 on an Ethernet/IP network?
The INMC-3402230500 supports cyclic data exchange at configurable RPI (Requested Packet Interval) rates, typically 10–100ms depending on network load and PLC scanner configuration. In a well-managed industrial Ethernet segment with a ConneXium managed switch, latency is deterministic and suitable for real-time drive control applications.

Q2: Is the INMC-3402230500 compatible with both Modbus TCP and Ethernet/IP simultaneously?
Yes. The module supports both Ethernet/IP (CIP) and Modbus TCP/IP protocols concurrently over the same RJ45 port, allowing a SCADA system using Modbus TCP to coexist with a PLC using Ethernet/IP on the same network segment without conflict.

Q3: Can this module be used to integrate Altivar drives into a Vijeo Citect or Wonderware SCADA system?
Absolutely. Both Vijeo Citect and Wonderware System Platform include native Modbus TCP and Ethernet/IP drivers. Once the INMC-3402230500 is configured with a valid IP address and the drive’s Modbus register map is imported, full bidirectional communication — including setpoint writing and fault acknowledgment — is operational within minutes.

Q4: What warranty and testing does ZYPLC provide for the INMC-3402230500?
All INMC-3402230500 units supplied by ZYPLC carry a warranty terms confirmed during quotation covering manufacturing defects and communication failures. Each unit is pre-tested for Ethernet link integrity, protocol response, and parameter exchange before shipment. Replacement or repair is provided at no charge within the warranty period, with express logistics support via DHL or FedEx.