Skip to main content

Siemens

Siemens 2XV9450-1AR23 Network Interface SICLOCK Systems

Siemens RFQ support for Time Synchronization Module. Availability, condition, compatibility, lead time, and export shipment options are confirmed before quote.

SKU2XV9450-1AR23 E10433-E9600-H110 BrandSiemens TypeTime Synchronization Module SeriesOther series OriginDE CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, confirmed before quote
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

In modern smart manufacturing environments, precise time synchronization is not merely a convenience — it is the backbone of reliable industrial data communication. The Siemens 2XV9450-1AR23 SICLOCK TM is a plant-level central clock module engineered to deliver accurate, stable, and protocol-compliant time signals across complex industrial network architectures. Designed for demanding automation environments, this module serves as the authoritative time source that synchronizes every node in the data chain — from field-level sensors and remote I/O to PLC controllers, HMI panels, SCADA servers, and edge computing gateways.

The 2XV9450-1AR23 operates across a wide power supply range of 90–230V AC/DC, making it adaptable to diverse plant electrical infrastructures without additional power conditioning. Its compact DIN-rail form factor integrates seamlessly into existing control cabinet layouts, minimizing installation footprint while maximizing network reach. With support for NTP and SNTP protocols, the module distributes synchronized time signals to all connected automation devices, ensuring that event logs, alarm timestamps, data acquisition records, and process control sequences are temporally coherent across the entire production network.

Compatibility & Integration Notes

Parameter Specification
SKU 2XV9450-1AR23
Brand Siemens
Series SICLOCK TM
Protocol Support NTP, SNTP
Interface Type Ethernet (RJ45), Serial
Power Supply 90–230V AC/DC
Transmission Capability Precision time distribution to all network nodes
Network Compatibility Industrial Ethernet, PROFINET, TCP/IP
System Application SCADA, PLC, HMI, Remote I/O, Edge Gateway, DCS
Origin Germany
Warranty 12-Month Warranty
Availability In Stock — RFQ Response within 24 Hours

Connected Automation Data Flow

The industrial data flow in a smart factory begins at the field level, where sensors, encoders, and actuators continuously generate process data. These devices — often connected through distributed I/O systems such as the Siemens ET 200SP remote I/O modules — rely on synchronized timestamps to ensure that signal acquisition sequences are accurately recorded and traceable. Without a reliable time source, data from multiple field nodes becomes temporally inconsistent, making fault diagnosis and process optimization unreliable.

The Siemens 2XV9450-1AR23 SICLOCK TM acts as the plant’s master clock, broadcasting NTP/SNTP time signals across the industrial Ethernet backbone. SIMATIC S7-1500 PLC controllers — the computational core of most modern automation cells — receive these time signals through their integrated PROFINET interfaces, ensuring that all ladder logic execution cycles, interrupt routines, and data logging operations are time-stamped with microsecond-level accuracy. This synchronization is equally critical for SIMATIC S7-300 and S7-400 series controllers deployed in legacy production lines, where CP 343-1 and CP 443-1 communication processors bridge the gap between older backplane architectures and modern Ethernet-based time distribution networks.

At the network infrastructure layer, Siemens SCALANCE X-200 and X-300 series managed industrial Ethernet switches relay the NTP time packets across ring and star topologies, maintaining network redundancy and minimizing packet jitter. These switches support PROFINET IRT (Isochronous Real-Time) communication, which demands sub-millisecond synchronization — a requirement that the 2XV9450-1AR23 is specifically designed to fulfill. The SCALANCE switches also provide SNMP-based network diagnostics, allowing plant engineers to monitor time synchronization health from a centralized SCADA workstation.

At the human-machine interface layer, Siemens SIMATIC HMI Comfort Panels display real-time process data with accurate timestamps derived from the SICLOCK TM time source. Operators monitoring production KPIs, alarm histories, and trend charts depend on this temporal accuracy to make informed decisions. Simultaneously, SIMATIC WinCC SCADA software aggregates time-stamped data from all PLC nodes, remote I/O stations, and drive systems — including Siemens SINAMICS G120 variable frequency drives — into a unified process historian. The integrity of this historian is entirely dependent on the consistency of the time source provided by the 2XV9450-1AR23.

For edge computing and IIoT integration scenarios, the SIMATIC IOT2050 edge gateway collects time-synchronized data from the plant network and forwards it to cloud analytics platforms or MES systems. The 2XV9450-1AR23 ensures that all data packets arriving at the IOT2050 carry coherent timestamps, enabling accurate machine learning model training, predictive maintenance algorithms, and OEE calculations. SITOP PSU8600 modular power supplies provide stable 24V DC power to the field devices and communication modules throughout this data chain, ensuring uninterrupted operation even during grid fluctuations.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the fragmentation of data across incompatible protocols and isolated network segments. Legacy field devices may communicate via Modbus RTU or PROFIBUS DP, while newer systems operate on PROFINET or Industrial Ethernet. Without a unified time reference, correlating events across these protocol boundaries becomes impossible — alarms may appear out of sequence, fault root-cause analysis becomes guesswork, and production reporting loses credibility.

The Siemens 2XV9450-1AR23 SICLOCK TM directly addresses this challenge by providing a single, authoritative NTP/SNTP time source that all network segments can reference, regardless of their underlying communication protocol. By synchronizing the SIMATIC S7-1500 PLC, the ET 200SP remote I/O, the SCALANCE network switches, the SIMATIC HMI panels, and the WinCC SCADA server to a common time base, the module eliminates temporal data islands and enables end-to-end process transparency.

Remote monitoring and diagnostics are also significantly enhanced. Plant engineers can remotely access time-stamped alarm logs and event records through the WinCC SCADA system, identifying the precise sequence of events that led to a production stoppage — even across multiple production cells operating on different network segments. This capability reduces mean time to repair (MTTR) and supports continuous improvement initiatives by providing accurate, time-correlated production data.

System scalability is another key advantage. As production lines expand and new automation cells are added, the 2XV9450-1AR23 can extend its time synchronization service to new network nodes without requiring infrastructure redesign. Its standard NTP/SNTP protocol support ensures compatibility with virtually any modern industrial device, making it a future-proof investment for growing smart factory environments. All units are pre-tested before shipment, with in-stock availability and a 12-month warranty covering manufacturing defects and operational failures.

Industrial Connectivity FAQ

Q1: What communication protocols does the Siemens 2XV9450-1AR23 support?
The 2XV9450-1AR23 SICLOCK TM supports NTP (Network Time Protocol) and SNTP (Simple Network Time Protocol), both of which are industry-standard protocols for time synchronization over Industrial Ethernet and TCP/IP networks. These protocols are natively compatible with SIMATIC S7-series PLCs, SCALANCE switches, SIMATIC HMI panels, and WinCC SCADA systems.

Q2: How does the module ensure network stability and minimize synchronization latency?
The SICLOCK TM is designed for continuous, uninterrupted time signal distribution with minimal jitter. Its dedicated time-keeping hardware maintains accuracy independent of network load fluctuations. When deployed with SCALANCE managed switches configured for PROFINET IRT, end-to-end synchronization latency is maintained well within the sub-millisecond range required by real-time automation applications.

Q3: Is the 2XV9450-1AR23 compatible with existing SCADA and HMI systems?
Yes. The module’s NTP/SNTP protocol support ensures broad compatibility with SIMATIC WinCC, WinCC Unified, and third-party SCADA platforms. SIMATIC HMI Comfort Panels and Basic Panels can synchronize their internal clocks directly from the SICLOCK TM via the plant Ethernet network, ensuring consistent timestamp accuracy across all operator interfaces.

Q4: What warranty and pre-shipment testing does ZYPLC provide for this module?
Every Siemens 2XV9450-1AR23 unit supplied by ZYPLC undergoes functional verification testing prior to shipment. All units are covered by a 12-month warranty against manufacturing defects and operational failures. In-stock units are available for immediate dispatch, with RFQ responses provided within 24 hours. For technical inquiries or bulk procurement, contact our team directly.


© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | plc.sales@zyplc.com