Skip to main content

Siemens

Siemens 6AU1390-0BA00-0AA0 Industrial Network Interface for SIMOVERT Systems

Siemens 6AU1390-0BA00-0AA0 SIMOVERT Communication Card — protocol gateway for SCADA, PLC & HMI integration. warranty terms confirmed during quotation. RFQ: plc.sales@zyplc.com

SKU6AU1390-0BA00-0AA0 A5E00320933 A5E00458182 BrandSiemens TypeCommunication Card SeriesSIMOVERT OriginDE CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Siemens 6AU1390-0BA00-0AA0 is a high-performance communication card engineered for the SIMOVERT drive series, delivering seamless protocol conversion and real-time data exchange across complex industrial automation architectures. As manufacturing sites evolve toward fully connected smart factories, the demand for reliable, low-latency communication between field devices, controllers, and supervisory systems has never been greater. This communication card addresses that demand directly — serving as the critical network interface that enables SIMOVERT drives to participate in unified industrial data flows.

With part references including A5E00320933 and A5E00458182, this card is a verified OEM component designed to integrate natively within Siemens drive ecosystems. It supports structured data exchange between the drive layer and upper-level control systems, making it an essential component for engineers designing or maintaining industrial communication networks.

Compatibility & Integration Notes

Parameter Specification
SKU / Part Number 6AU1390-0BA00-0AA0 (A5E00320933 / A5E00458182)
Brand Siemens
Series SIMOVERT
Product Type Communication Card / Network Interface Module
Protocol Support PROFIBUS DP, USS Protocol, Serial Communication
Interface Type Drive Communication Slot Interface
Transmission Capability Real-time cyclic and acyclic data exchange
Network Compatibility PROFIBUS, Industrial Ethernet (via gateway), Siemens SIMATIC architecture
System Application SCADA integration, PLC-to-Drive communication, HMI data visualization, Remote diagnostics
Origin Germany
Warranty warranty terms confirmed during quotation
Availability RFQ Available — shipment arranged after confirmation

Connected Automation Data Flow

In a typical smart factory deployment, the Siemens 6AU1390-0BA00-0AA0 sits at the intersection of the drive layer and the plant-wide communication backbone. Signal acquisition begins at the sensor and actuator level — temperature transmitters, pressure sensors, and encoder feedback units feed real-time process data into the SIMOVERT drive. The 6AU1390-0BA00-0AA0 communication card then structures this data and transmits it upstream via PROFIBUS DP to a Siemens SIMATIC S7-300 or S7-400 PLC, where logic processing and closed-loop control decisions are executed.

From the PLC layer, data flows onward to Siemens ET 200S or ET 200M remote I/O stations, which distribute control signals back to field devices across the production line. Simultaneously, the communication card enables the SIMOVERT drive to report operational parameters — motor speed, torque, fault codes, and energy consumption — to a Siemens SIMATIC WinCC SCADA platform, where operators monitor production KPIs in real time.

For HMI-level visualization, the data stream reaches Siemens SIMATIC HMI TP700 Comfort or similar panel units, giving line operators immediate access to drive status and alarm conditions without navigating complex menu structures. In multi-drive installations, a Siemens SCALANCE X208 industrial Ethernet switch manages network segmentation and ensures deterministic data delivery across the PROFIBUS and Ethernet segments.

Where legacy field devices communicate via USS protocol or serial RS-485, the 6AU1390-0BA00-0AA0 acts as the protocol bridge, converting drive-native communication into formats compatible with upstream Siemens S7-1200 controllers or third-party SCADA gateways. In distributed drive applications — such as conveyor systems, pump stations, or compressor banks — multiple SIMOVERT units equipped with this communication card can be networked under a single Siemens SINAMICS G120 Control Unit or coordinated through a Siemens SINAUT ST7 remote terminal unit for wide-area monitoring.

Edge computing nodes, such as the Siemens SIMATIC IPC427E industrial PC, can aggregate drive data from multiple 6AU1390-0BA00-0AA0-equipped units and push processed datasets to MES or ERP platforms via OPC-UA, completing the vertical integration from field device to enterprise system.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the fragmentation of communication protocols across different equipment generations and vendors. A production line may simultaneously operate devices using PROFIBUS DP, Modbus RTU, DeviceNet, and proprietary serial protocols — creating data silos that prevent unified monitoring and control. The Siemens 6AU1390-0BA00-0AA0 directly addresses this by providing a standardized communication interface for SIMOVERT drives, enabling them to participate in PROFIBUS-based networks alongside PLCs, remote I/O, and SCADA systems without requiring custom protocol converters or middleware.

For sites undergoing digital transformation, this communication card is a foundational component for production line transparency. By connecting SIMOVERT drives to SCADA platforms, maintenance teams gain access to historical trend data, predictive fault indicators, and remote parameter adjustment capabilities — eliminating the need for on-site manual inspection of individual drive units. Alarm feedback loops can be configured to trigger automated responses in the PLC layer, reducing mean time to repair (MTTR) and minimizing unplanned downtime.

System scalability is another key advantage. As production capacity expands, additional SIMOVERT drives equipped with the 6AU1390-0BA00-0AA0 can be added to the PROFIBUS network without architectural redesign. The card’s compatibility with Siemens SIMATIC engineering tools — including STEP 7 and TIA Portal — ensures that network configuration, diagnostics, and firmware management remain centralized and consistent across the entire drive fleet.

Remote diagnostics capability is particularly valuable for geographically distributed facilities. Through the SCADA layer, engineers can remotely interrogate drive parameters, review fault histories, and initiate controlled restarts — reducing travel costs and accelerating fault resolution. All units supplied by ZYPLC undergo pre-shipment functional testing to verify communication integrity, protocol handshake performance, and parameter read/write accuracy before dispatch.

Industrial Connectivity FAQ

Q1: What communication protocols does the Siemens 6AU1390-0BA00-0AA0 support?
The 6AU1390-0BA00-0AA0 is designed for use with the SIMOVERT drive series and supports PROFIBUS DP cyclic and acyclic communication as well as the USS serial protocol. It enables structured data exchange between SIMOVERT drives and Siemens SIMATIC PLCs, SCADA systems, and HMI platforms within standard industrial network architectures.

Q2: How does this communication card affect network latency in real-time control applications?
The card is engineered for deterministic, low-latency data transmission consistent with PROFIBUS DP timing requirements. In properly configured networks with appropriate baud rate settings and network topology, cyclic data exchange between the SIMOVERT drive and the PLC master occurs within millisecond-range cycle times, suitable for closed-loop drive control and real-time process monitoring applications.

Q3: Is the 6AU1390-0BA00-0AA0 compatible with TIA Portal and STEP 7 engineering environments?
Yes. The card integrates within Siemens SIMATIC engineering frameworks, allowing network configuration, GSD file-based device description, and diagnostic access through both STEP 7 Classic and TIA Portal environments. This ensures compatibility with existing Siemens automation infrastructure and simplifies commissioning in multi-drive installations.

Q4: What warranty and pre-shipment testing does ZYPLC provide for this unit?
All Siemens 6AU1390-0BA00-0AA0 units supplied by ZYPLC are covered by a warranty terms confirmed during quotation from the date of shipment. Each unit undergoes pre-shipment functional testing including communication protocol verification, interface integrity checks, and parameter read/write validation. Availability is confirmed via RFQ for shipment arranged after confirmation with full traceability documentation. For volume orders or urgent requirements, contact our team directly.


© 2026 ZYPLC. All rights reserved.

Contact: +86 19859288691 | plc.sales@zyplc.com