Skip to main content

Siemens

Siemens 6AU1400-2PA02-0AA0 Memory Card for SIMOTION

Siemens 6AU1400-2PA02-0AA0 SIMOTION CompactFlash card. RFQ compatibility review for motion control architecture. warranty terms confirmed during quotation. export shipping options available.

SKU6AU1400-2PA02-0AA0 BrandSiemens TypeCompactFlash Memory Card SeriesSIMOTION OriginDE CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Siemens 6AU1400-2PA02-0AA0 Memory Card: Control System and Coordinated Automation Design

The Siemens 6AU1400-2PA02-0AA0 is a SIMOTION-series CompactFlash memory card engineered to serve as the persistent storage backbone within Siemens motion control architectures. Rather than functioning as a standalone peripheral, this module is deeply embedded in the layered structure of a complete automation system — bridging the control layer, I/O layer, communication layer, and execution layer into a coherent, maintainable, and scalable platform. Its role in system integration ensures that every firmware image, motion program, and parameter dataset is consistently available across system restarts, firmware updates, and hardware replacements, making it indispensable for high-availability industrial environments.

In modern industrial automation, the reliability of a motion controller is only as strong as its storage medium. The 6AU1400-2PA02-0AA0 provides the SIMOTION D or SIMOTION C platform with a stable, non-volatile memory environment that retains all project data, drive parameters, and communication configurations. When paired with a SIMOTION D445-2 or SIMOTION D435-2 controller, this CompactFlash card ensures that the entire motion program — including cam profiles, positioning sequences, and synchronization logic — is preserved and immediately executable upon power restoration, eliminating costly re-commissioning cycles in production environments.

Product Specification Table

Parameter Specification
Part Number 6AU1400-2PA02-0AA0
Brand Siemens
Series SIMOTION
Product Type CompactFlash Memory Card
System Role Non-volatile program and parameter storage for SIMOTION controllers
Compatible Platforms SIMOTION D, SIMOTION C, SIMOTION P
Interface CompactFlash (CF) Type II
Communication Compatibility PROFIBUS DP, PROFINET IO, Industrial Ethernet
Operating Temperature 0 °C to +60 °C (controller-dependent)
Installation Environment Control cabinet, DIN rail-mounted controller slot
Origin Germany
Warranty warranty terms confirmed during quotation
system integration Full — retains project, firmware, and drive parameters across power cycles

System Compatibility Notes

The 6AU1400-2PA02-0AA0 does not operate in isolation — it is a critical node in a multi-layer automation architecture. At the control layer, it works directly with the SIMOTION D445-2 or SIMOTION D435-2 motion controller, storing the runtime firmware and all user-defined motion programs. The controller reads from this card at startup, making the integrity and compatibility of the card essential to system boot reliability.

At the drive layer, the card stores parameter sets for SINAMICS S120 drive units, including axis-specific configurations for booksize power modules and motor modules. When a SINAMICS S120 Control Unit CU320-2 is integrated into the same rack or cabinet, the 6AU1400-2PA02-0AA0 ensures that all drive parameters are synchronized with the motion controller’s project data, enabling seamless axis coordination without manual re-parameterization after a hardware swap.

At the I/O layer, the card preserves the configuration of distributed I/O nodes connected via PROFINET IO or PROFIBUS DP, including ET 200SP or ET 200M remote I/O stations. This means that digital input modules, analog output modules, and safety I/O modules all retain their logical assignments and process image configurations, reducing the risk of signal mapping errors during maintenance windows.

At the communication layer, the stored project data includes PROFINET device names, IP address assignments, and PROFIBUS node addresses for all connected field devices. This system integration capability ensures that after a controller replacement, the network topology is restored automatically from the CompactFlash card, without requiring manual reconfiguration of each network node.

At the human-machine interface layer, SIMATIC HMI panels such as the TP1500 Comfort or KTP900 Basic connected to the SIMOTION controller rely on consistent tag structures and communication variables. Because the 6AU1400-2PA02-0AA0 preserves the complete project database, HMI tag mappings remain valid across firmware updates, preventing operator interface failures during production transitions.

At the power layer, the card supports architectures that include SITOP PSU8600 power supply modules, where redundant power configurations require that the motion controller restarts cleanly and deterministically. The CompactFlash card’s fast read performance ensures minimal boot time, supporting rapid system recovery in redundant power switchover scenarios.

Industrial Application Notes

Manufacturing and Packaging Lines: In high-speed packaging machinery, the 6AU1400-2PA02-0AA0 enables SIMOTION-controlled servo axes to resume synchronized motion profiles immediately after an emergency stop or power interruption. Cam-based motion sequences for film cutting, sealing, and labeling are stored on the card and executed without re-teaching, maintaining throughput consistency across production shifts.

Power Generation and Energy Infrastructure: In turbine control and generator synchronization applications, the card stores the motion programs that govern valve positioning and speed ramp profiles. Its non-volatile storage ensures that critical control logic is not lost during grid disturbances, supporting the reliability requirements of power plant automation systems.

Petrochemical and Process Control: In continuous process environments such as compressor control or pump station automation, the 6AU1400-2PA02-0AA0 retains the process parameter sets that define flow rates, pressure setpoints, and interlock logic. This supports long-term operational consistency without requiring re-commissioning after planned maintenance shutdowns.

Mining and Metallurgy: In conveyor drive systems and rolling mill applications, the card stores the torque profiles and speed ramp parameters for SINAMICS-driven motors. Its robust storage architecture supports the high-vibration, high-temperature environments typical of heavy industry, where data integrity is critical to preventing unplanned downtime.

Water and Wastewater Treatment: In pump station and filtration system automation, the card enables SIMOTION controllers to manage multi-pump sequencing and variable-speed drive coordination. Stored parameter sets ensure that pump rotation schedules and flow balancing algorithms are preserved across seasonal shutdowns and maintenance cycles.

Product Compatibility FAQ

Q1: Is the 6AU1400-2PA02-0AA0 compatible with all SIMOTION controller variants, and can it be used as a direct replacement in an existing system?
The 6AU1400-2PA02-0AA0 is designed for use with SIMOTION D and SIMOTION C platform controllers that accept a CompactFlash Type II interface. Before installation, verify the firmware version stored on the card matches the SIMOTION runtime version required by your project. In most cases, the card can be used as a direct replacement by copying the existing project backup onto the new card using SIMOTION SCOUT engineering software, ensuring full architectural compatibility without re-commissioning.

Q2: How does this CompactFlash card support redundant architecture designs, and what happens during a controller failover event?
In redundant SIMOTION architectures, each controller unit maintains its own CompactFlash card with an identical project image. During a failover event, the standby controller reads its stored project data from the 6AU1400-2PA02-0AA0 and assumes control without requiring operator intervention. This system integration capability ensures that the redundant controller’s firmware, drive parameters, and communication configurations are always synchronized with the active controller’s last saved state, minimizing switchover time and maintaining process continuity.

Q3: What does the warranty terms confirmed during quotation cover, and how is long-term spare parts availability managed for this component?
The 6AU1400-2PA02-0AA0 is supplied with a warranty terms confirmed during quotation covering manufacturing defects and functional failures under normal operating conditions. For long-term maintenance planning, it is recommended to maintain at least one spare card per SIMOTION controller in your installed base, pre-loaded with the current project image. This practice reduces mean time to repair (MTTR) in the event of card failure and ensures that your automation architecture can be restored to full operation within a single maintenance shift. Contact our team for volume pricing and long-term supply agreements.