Skip to main content

Siemens

Siemens 6AV2124-0UC24-1AX0 Industrial Network Interface for SIMATIC Systems

Siemens 6AV2124-0UC24-1AX0 PROFINET HMI touch panel for SIMATIC WinCC SCADA integration. Protocol gateway, real-time data, 12-month warranty. RFQ zyplc.com

SKU6AV2124-0UC24-1AX0/6AV7424-7GA03-0AS0 BrandSiemens TypeHMI Touch Panel SeriesWinCC OriginDE CategoryPLC Systems
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Siemens 6AV2124-0UC24-1AX0 Industrial Network Interface for SIMATIC Systems: Bridging the Industrial Data Link in Smart Factory Environments

The Siemens 6AV2124-0UC24-1AX0 is a 12-inch PROFINET-enabled SIMATIC HMI touch panel engineered for high-performance human-machine interaction at the heart of modern industrial automation networks. As a critical node in the industrial data link, this panel connects field-level devices — including PLCs, remote I/O modules, variable frequency drives, and intelligent sensors — to supervisory SCADA and MES platforms through a robust PROFINET communication backbone. Designed for demanding smart factory environments, the 6AV2124-0UC24-1AX0 delivers real-time visualization, alarm management, and remote diagnostics across complex multi-layer network architectures, making it an indispensable component for plant-wide connectivity and operational transparency.

Built on the SIMATIC WinCC flexible runtime environment, this HMI panel supports seamless integration with Siemens S7-1500, S7-1200, and S7-300/400 PLC families via PROFINET IO, enabling deterministic, low-latency data exchange between the control layer and the operator interface. Its high-resolution widescreen display and multi-touch capability allow operators to monitor process variables, configure setpoints, and respond to alarms with precision — all from a single, centralized visualization node on the factory floor.

Network Communication Table

Parameter Specification
Primary SKU 6AV2124-0UC24-1AX0
Alternate SKU 6AV7424-7GA03-0AS0
Brand / Series Siemens SIMATIC HMI Comfort Panel
Communication Protocol PROFINET IO (IRT / RT), Ethernet TCP/IP
Interface Type RJ45 PROFINET Port × 2 (integrated switch), USB Host/Device
Display Size 12″ Widescreen TFT, Multi-Touch
Transmission Capability 100 Mbit/s Full Duplex PROFINET
Network Compatibility PROFINET, Industrial Ethernet, OPC UA (via WinCC)
PLC Compatibility Siemens S7-1500, S7-1200, S7-300/400, SINAMICS Drives
SCADA / HMI Software SIMATIC WinCC Comfort / Advanced / SCADA
System Application Smart Factory, Process Visualization, Remote Diagnostics, Alarm Management
Origin Germany
Warranty 12-Month Warranty

Connected Automation Data Flow

In a fully integrated smart factory architecture, the 6AV2124-0UC24-1AX0 operates as the visualization and interaction hub within a layered PROFINET network. At the field level, distributed I/O devices such as the Siemens ET 200SP and ET 200MP remote I/O stations collect analog and digital signals from pressure transmitters, flow meters, temperature sensors, and proximity switches. These signals are transmitted via PROFINET IO to a Siemens S7-1500 PLC — for example, the CPU 1516-3 PN/DP — where the control logic processes the data and generates setpoint commands, interlock signals, and alarm conditions.

The 6AV2124-0UC24-1AX0 connects directly to the S7-1500 controller over PROFINET, receiving real-time process values and displaying them on its 12-inch multi-touch interface. Operators can acknowledge alarms, adjust PID setpoints, and initiate manual overrides directly from the panel. Simultaneously, the HMI communicates upstream to a SIMATIC WinCC SCADA server via Industrial Ethernet, enabling plant-wide data aggregation, trend logging, and remote monitoring from the control room.

In drive-intensive applications — such as conveyor systems, pump stations, or compressor lines — the panel integrates with SINAMICS G120 and SINAMICS S120 variable frequency drives via the S7-1500 controller, providing real-time speed feedback, energy consumption data, and fault diagnostics on the operator screen. For motion control applications, the panel works alongside the SIMOTION D controller series, visualizing axis positions, torque values, and motion program states.

At the network infrastructure layer, Siemens SCALANCE X series industrial Ethernet switches provide the managed switching backbone that connects the HMI panel, PLCs, remote I/O, and drives into a coherent PROFINET ring or star topology. The SCALANCE X208 or X216 switches support PROFINET Media Redundancy Protocol (MRP), ensuring network continuity even in the event of a cable fault — a critical requirement for continuous process industries.

For sites requiring protocol bridging between legacy fieldbus systems and modern PROFINET networks, the Siemens IE/PB Link PN IO gateway converts PROFIBUS DP signals from older S7-300 controllers or third-party field devices into PROFINET frames, allowing the 6AV2124-0UC24-1AX0 to visualize data from both legacy and modern automation layers on a single unified interface. Similarly, the SIMATIC S7-1200 with CM 1241 RS485 communication module can bridge Modbus RTU devices — such as energy meters, barcode readers, or third-party sensors — into the PROFINET data stream accessible by the HMI panel.

Edge connectivity is further extended through the SIMATIC IPC (Industrial PC) platform running WinCC Advanced or WinCC OA, which aggregates data from multiple HMI panels including the 6AV2124-0UC24-1AX0, enabling cross-line KPI dashboards, OEE calculations, and MES integration. This complete data chain — from field sensor through PLC, PROFINET switch, HMI panel, and SCADA server to the enterprise MES — forms the backbone of a transparent, data-driven smart factory.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is data isolation — the condition where field devices, controllers, and supervisory systems operate in disconnected silos, preventing plant managers from achieving real-time visibility across the production floor. The Siemens 6AV2124-0UC24-1AX0 directly addresses this challenge through its native PROFINET IO communication capability and deep integration with the SIMATIC WinCC ecosystem.

In facilities where multiple communication protocols coexist — PROFIBUS DP, Modbus RTU, DeviceNet, or CANopen — the 6AV2124-0UC24-1AX0, when paired with appropriate protocol gateways and communication modules, serves as the unified visualization layer that presents data from all protocol domains on a single operator interface. This eliminates the need for operators to consult multiple standalone displays or manually reconcile data from disparate systems.

Remote monitoring is another critical capability enabled by this HMI panel. Through the SIMATIC Remote Access solution and WinCC’s built-in web server functionality, authorized personnel can access live process screens, alarm logs, and trend data from any location via a standard web browser — without requiring dedicated VPN hardware at every remote site. This capability is particularly valuable for multi-site manufacturers, OEM machine builders, and service engineers who need to diagnose faults and optimize processes without being physically present on the factory floor.

Production line transparency is achieved through the panel’s integrated alarm and event logging system, which records every operator action, process deviation, and system fault with a precise timestamp. These logs can be exported to CSV or integrated with SIMATIC WinCC’s SQL database for long-term analysis, regulatory compliance reporting, and root cause investigation. System expansion is straightforward: the PROFINET network can accommodate additional HMI panels, I/O stations, drives, and controllers without architectural redesign, supporting phased capacity growth as production demands evolve.

Every unit of the 6AV2124-0UC24-1AX0 supplied by ZYPLC undergoes pre-shipment functional testing to verify communication integrity, display performance, and interface operation. Stock availability is maintained to support urgent project timelines, and all units are covered by a 12-month warranty against manufacturing defects.

Industrial Connectivity FAQ

Q1: What is the communication latency of the 6AV2124-0UC24-1AX0 over PROFINET?
The 6AV2124-0UC24-1AX0 supports PROFINET RT (Real-Time) with cycle times as low as 1 ms and PROFINET IRT (Isochronous Real-Time) for motion-critical applications. In standard HMI visualization applications, screen update rates are configurable from 100 ms to several seconds depending on the number of tags and network load, ensuring responsive operator feedback without overloading the PROFINET network.

Q2: Is the 6AV2124-0UC24-1AX0 compatible with third-party PLCs and SCADA systems?
While natively optimized for Siemens SIMATIC controllers and WinCC SCADA, the panel supports OPC UA client/server communication (via WinCC Advanced), enabling data exchange with third-party SCADA platforms such as Wonderware, iFIX, and Ignition. Direct connection to non-Siemens PLCs is possible through Modbus TCP, Ethernet/IP (with appropriate drivers), or via OPC UA, making it suitable for mixed-vendor automation environments.

Q3: How does the panel maintain network stability in harsh industrial environments?
The 6AV2124-0UC24-1AX0 is designed to operate in industrial environments with wide temperature ranges, high vibration, and electromagnetic interference. Its dual PROFINET ports support MRP (Media Redundancy Protocol) ring topologies, providing automatic network failover in under 200 ms. The panel’s fanless design and IP65-rated front face ensure reliable operation in dusty, humid, or wash-down environments without compromising network communication stability.

Q4: What does the 12-month warranty cover, and what is the shipping lead time?
All 6AV2124-0UC24-1AX0 units supplied by ZYPLC are covered by a 12-month warranty against manufacturing defects, covering hardware failures under normal operating conditions. Pre-shipment testing is performed on every unit to verify PROFINET communication, display function, and interface integrity before dispatch. Stock units are available for immediate shipment; lead times for non-stock configurations are confirmed at the time of order. Contact our team at plc.sales@zyplc.com or +86 19859288691 for availability and pricing.

© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | plc.sales@zyplc.com