Skip to main content

Siemens

Siemens 6AV2124-1QC02-0AX1 Industrial Network Interface for TP1500 Comfort Systems

Siemens 6AV2124-1QC02-0AX1 TP1500 Comfort PROFINET HMI touch panel – industrial gateway for SCADA, PLC communication, real-time monitoring. 12-month warranty from ZYPLC.

SKU6AV2124-1QC02-0AX1 BrandSiemens TypeHMI Touch Panel SeriesSIMATIC OriginDE CategoryHMI Panels
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Siemens 6AV2124-1QC02-0AX1: Industrial Data Link for Smart Factory Connectivity

The Siemens 6AV2124-1QC02-0AX1 is a SIMATIC TP1500 Comfort 15-inch widescreen TFT HMI touch panel engineered for high-performance industrial network communication. Designed to serve as the critical human-machine interface node in modern smart factory architectures, this unit bridges field-level devices, PLC controllers, remote I/O systems, SCADA platforms, and upper-level management systems through a robust PROFINET communication backbone. Whether deployed in discrete manufacturing, process automation, or hybrid production environments, the 6AV2124-1QC02-0AX1 delivers real-time data visibility, alarm management, and remote diagnostics across the entire automation chain.

At ZYPLC, every unit of the 6AV2124-1QC02-0AX1 is sourced from verified supply channels, pre-shipment tested for communication integrity, and backed by a 12-month warranty. In-stock inventory ensures rapid global dispatch to support urgent production line requirements.

Network Communication Table

Parameter Specification
SKU / Part Number 6AV2124-1QC02-0AX1
Series SIMATIC TP1500 Comfort
Communication Protocol PROFINET IO, PROFIBUS DP, MPI, Modbus TCP/IP, OPC UA
Interface Type RJ45 Ethernet (PROFINET), RS-422/485 (PROFIBUS/MPI), USB Host/Device
Display 15.4-inch Widescreen TFT, 1280 × 800 px, 16M Colors
Transmission Capability 100 Mbit/s PROFINET; Real-time cyclic data exchange
Network Compatibility SIMATIC S7-1200, S7-1500, S7-300, S7-400, WinCC, TIA Portal V14+
System Application SCADA Integration, PLC Visualization, Remote I/O Monitoring, Drive Control HMI
Operating System Windows Embedded Compact 7
Warranty 12-Month Warranty | Pre-shipment Tested | In-Stock Supply

Connected Automation Data Flow

In a typical smart factory deployment, the 6AV2124-1QC02-0AX1 sits at the convergence point of multiple data streams. Signal acquisition begins at the field level, where sensors, encoders, and actuators feed raw process data into remote I/O modules such as the Siemens ET 200SP (6ES7151-8AB01-0AB0). These distributed I/O nodes communicate upstream via PROFINET to a central PLC — commonly a SIMATIC S7-1500 (6ES7515-2AM02-0AB0) or S7-300 (6ES7315-2EH14-0AB0) — where logic processing and control decisions are executed in real time.

The 6AV2124-1QC02-0AX1 connects directly to this PROFINET segment, pulling live process variables, alarm states, and production counters from the PLC and rendering them on its 15.4-inch TFT display for operator interaction. Simultaneously, the panel communicates with SCADA systems via OPC UA or Modbus TCP/IP, enabling plant-wide data aggregation and historian logging. In multi-panel installations, additional SIMATIC TP1200 Comfort (6AV2124-0MC01-0AX0) units may be deployed at secondary workstations, all sharing the same PROFINET network segment managed through a Siemens SCALANCE X208 industrial Ethernet switch (6GK5208-0BA10-2AA3).

For drive integration, the panel interfaces with SINAMICS G120 variable frequency drives (6SL3210-1KE21-3AF1) via PROFINET, displaying speed references, torque feedback, and fault diagnostics without additional gateway hardware. Where legacy PROFIBUS devices remain in the field — such as older SIMATIC S7-300 CPUs or third-party field instruments — the CP 343-1 communication processor (6GK7343-1EX30-0XE0) or a dedicated PROFIBUS-to-PROFINET gateway (6GK7243-1BX30-0XE0) bridges the protocol gap, ensuring the 6AV2124-1QC02-0AX1 maintains a unified data view across mixed-protocol environments.

Edge computing nodes and industrial IoT gateways further extend the data chain, forwarding aggregated production metrics from the PROFINET layer to cloud-based MES or ERP platforms. The 6AV2124-1QC02-0AX1 supports this architecture natively through its OPC UA server capability, making it a natural anchor point for Industry 4.0 data pipelines. Power supply stability across the panel network is maintained by Siemens SITOP PSU100S (6EP1334-2BA20) DIN-rail power supplies, ensuring uninterrupted HMI operation even during grid fluctuations.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is data isolation — the condition where field devices, PLCs, drives, and management systems operate in disconnected silos, preventing real-time visibility and coordinated control. The 6AV2124-1QC02-0AX1 directly addresses this problem through its multi-protocol communication architecture.

By supporting PROFINET IO, PROFIBUS DP, MPI, Modbus TCP/IP, and OPC UA simultaneously, the panel eliminates the need for separate protocol converters in most mixed-device environments. Operators gain a single, unified visualization layer that aggregates data from heterogeneous field devices — regardless of whether they speak PROFINET or legacy serial protocols. This transparency extends to alarm management: fault signals from remote I/O, drives, and sensors are consolidated on the HMI display with timestamped event logs, enabling rapid root-cause analysis without physical inspection of distributed field cabinets.

Remote monitoring and diagnostics are further enhanced through the panel’s Ethernet connectivity. Maintenance engineers can access live process screens, modify setpoints, and acknowledge alarms from remote workstations via VNC or SCADA client connections, reducing unplanned downtime and travel costs. For production line transparency, the 6AV2124-1QC02-0AX1 supports recipe management, trend logging, and report generation — giving production managers real-time OEE data without relying on manual data collection.

System expansion is equally straightforward. The PROFINET IO architecture supports hot-plugging of additional remote I/O stations and drive nodes without reconfiguring the entire network. As production capacity grows, new SIMATIC ET 200SP islands or SINAMICS drive groups can be added to the existing PROFINET ring, with the 6AV2124-1QC02-0AX1 automatically discovering and visualizing the new devices through TIA Portal-configured device templates.

Industrial Connectivity FAQ

Q1: What is the communication latency of the 6AV2124-1QC02-0AX1 over PROFINET?
The 6AV2124-1QC02-0AX1 supports PROFINET IO with cycle times as low as 1 ms in IRT (Isochronous Real-Time) mode, making it suitable for motion control and high-speed process monitoring applications. Standard RT mode provides cycle times of 4–512 ms, configurable via TIA Portal.

Q2: Is the 6AV2124-1QC02-0AX1 compatible with third-party PLCs and SCADA systems?
Yes. In addition to native Siemens SIMATIC integration, the panel supports Modbus TCP/IP and OPC UA, enabling connectivity with Allen-Bradley, Mitsubishi, Omron, and other third-party controllers. SCADA platforms such as Wonderware, Ignition, and WinCC can connect via OPC UA client interfaces.

Q3: How is network stability ensured in high-EMI industrial environments?
The 6AV2124-1QC02-0AX1 is rated for industrial EMC compliance (CE, UL) and supports PROFINET Media Redundancy Protocol (MRP) for ring topology failover. Combined with shielded RJ45 cabling and Siemens SCALANCE managed switches, network uptime is maintained even in high-interference environments such as welding lines and motor drive cabinets.

Q4: What does the 12-month warranty from ZYPLC cover, and how is pre-shipment testing conducted?
Every 6AV2124-1QC02-0AX1 unit shipped by ZYPLC undergoes pre-shipment functional testing including PROFINET communication verification, touchscreen calibration, display pixel check, and power-on self-test. The 12-month warranty covers hardware defects and communication failures under normal operating conditions. Replacement or repair is arranged within the warranty period at no additional cost.


© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | plc.sales@zyplc.com