Skip to main content

Siemens

Siemens 6RX1800-0AS50 Sinewave Filter for SINAMICS Systems

Siemens 6RX1800-0AS50 SINAMICS Sinewave Filter for industrial networks. Protocol-ready, EMC-compliant, warranty terms confirmed during quotation. export shipping options available from ZYPLC.

SKU6RX1800-0AS50 BrandSiemens TypeSinewave Filter SeriesSINAMICS OriginDE CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

The Siemens 6RX1800-0AS50 is a precision-engineered SINAMICS Sinewave Filter designed to serve as a critical output network interface component between variable frequency drives and connected motor loads in demanding industrial automation environments. As smart factories increasingly rely on seamless, high-integrity data and power transmission across distributed control architectures, the 6RX1800-0AS50 plays an indispensable role in ensuring signal fidelity, reducing electromagnetic interference, and protecting motor insulation from the harmful effects of high-frequency switching transients generated by modern PWM-based inverter drives.

In industrial sites where PROFINET, PROFIBUS, and EtherNet/IP protocols govern the communication backbone between PLCs, remote I/O modules, HMI panels, and SCADA systems, the integrity of the power delivery network is just as critical as the data network itself. The 6RX1800-0AS50 addresses this by filtering the drive output waveform into a near-sinusoidal voltage profile, dramatically reducing dV/dt stress on motor windings and bearing currents that can corrupt encoder feedback signals and disrupt fieldbus communication timing.

Compatibility & Integration Notes

Parameter Specification
SKU / Part Number 6RX1800-0AS50
Brand / Manufacturer Siemens
Series SINAMICS
Product Type Sinewave Filter (Output Filter)
Protocol Compatibility PROFINET, PROFIBUS-DP, EtherNet/IP, Modbus TCP (drive-side integration)
Interface Type Drive Output / Motor Terminal Interface
Transmission Capability Sinusoidal output waveform, reduced dV/dt, low harmonic distortion
Network Compatibility Compatible with SINAMICS G120, S120, G150, S150 drive platforms
System Application Smart Factory, SCADA Integration, PLC-controlled Motor Drives, Remote I/O Networks
Origin Germany
Warranty 12 Months
Availability RFQ Available — export shipping options available

Connected Automation Data Flow

In a fully integrated SINAMICS-based automation architecture, the 6RX1800-0AS50 sits at the intersection of power delivery and network communication integrity. Consider a typical smart factory cell: a Siemens S7-1500 PLC issues motion commands over PROFINET to a SINAMICS G120 drive equipped with a CU240E-2 PN Control Unit. The drive modulates output voltage at high switching frequencies to control motor speed and torque. Without a sinewave filter, the resulting voltage spikes propagate along motor cables, inducing noise into nearby ET 200SP remote I/O modules and corrupting the 4–20 mA analog signals from connected pressure and flow sensors.

By installing the 6RX1800-0AS50 at the drive output, the sinusoidal waveform restoration eliminates these interference sources. The SIMATIC HMI TP1200 Comfort panel connected to the PROFINET ring can now display accurate real-time motor current, speed, and fault data without noise-induced dropouts. Upstream, the SINEMA Remote Connect gateway aggregates drive diagnostics and forwards them to the plant SCADA system — enabling remote monitoring of motor health, energy consumption, and predictive maintenance alerts without requiring on-site intervention.

In multi-drive installations, the 6RX1800-0AS50 works alongside SINAMICS S120 booksize drive modules and Active Line Modules (ALM) to maintain a clean power bus. The SCALANCE X208 industrial Ethernet switch manages the PROFINET traffic between the PLC, drives, and I/O peripherals, while the sinewave filter ensures that the physical layer — the motor and its cabling — does not become a source of electromagnetic disturbance that degrades network performance. For applications involving long motor cable runs exceeding 100 meters, the 6RX1800-0AS50 is particularly critical, as it prevents reflected wave phenomena that can damage motor insulation and trigger nuisance drive trips.

In conveyor, pump, fan, and compressor applications, the filter integrates seamlessly with SINAMICS G150 cabinet drives and supports connection to SIRIUS 3RW soft starters in hybrid motor control centers. Edge computing nodes such as the SIMATIC IPC427E can collect filtered, high-quality motor data for AI-based anomaly detection and OEE optimization, feeding insights back to the MES layer through OPC UA over standard industrial Ethernet infrastructure.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in industrial automation is the fragmentation of data across incompatible protocols and isolated subsystems. A plant may operate Siemens SINAMICS drives on PROFINET alongside legacy PROFIBUS-DP devices, third-party Modbus RTU sensors, and EtherNet/IP-based safety controllers — each generating valuable operational data that remains siloed within its own network segment.

The 6RX1800-0AS50 contributes to breaking down these silos not by acting as a protocol gateway itself, but by ensuring that the physical integrity of the drive-motor interface does not become a bottleneck or noise source that undermines the reliability of the broader communication network. When motor-induced EMI is eliminated at the source, fieldbus communication error rates drop, PLC cycle times stabilize, and SCADA historians receive clean, consistent data streams that accurately reflect plant conditions.

For remote monitoring and diagnostics, the clean motor interface enabled by the 6RX1800-0AS50 allows drive fault codes, energy consumption data, and motor temperature readings to be reliably transmitted through PROFINET to cloud-connected SCADA platforms. Plant engineers can diagnose motor issues, adjust drive parameters, and verify filter performance from remote locations — reducing unplanned downtime and eliminating the need for costly on-site service visits. Production line transparency improves as every motor in the network becomes a visible, addressable data point within the plant’s digital twin.

System expansion is equally simplified. Adding new drive-motor pairs to an existing SINAMICS network requires only that each new drive output be equipped with an appropriate sinewave filter — such as the 6RX1800-0AS50 — to maintain the EMC compliance and network stability of the entire installation. This modular approach supports phased factory upgrades without disrupting ongoing production.

Every 6RX1800-0AS50 unit supplied by ZYPLC undergoes pre-shipment functional testing to verify filter performance, insulation integrity, and terminal connection quality. Units are shipped with full documentation and are backed by a warranty terms confirmed during quotation, ensuring confidence in both product quality and supply chain reliability.

Industrial Connectivity FAQ

Q1: Does the 6RX1800-0AS50 affect PROFINET communication latency between the SINAMICS drive and the S7-1500 PLC?
A: No. The 6RX1800-0AS50 is an output power filter installed between the drive and the motor — it operates entirely in the power domain and has no effect on the PROFINET data communication between the drive’s control unit and the PLC. PROFINET cycle times and isochronous real-time (IRT) performance remain unaffected.

Q2: Is the 6RX1800-0AS50 compatible with both SINAMICS G120 and S120 drive platforms?
A: Yes. The 6RX1800-0AS50 is designed for use within the SINAMICS product family and is compatible with multiple drive platforms including the G120, S120, G150, and S150 series, subject to matching the rated voltage, current, and switching frequency parameters specified in the Siemens SINAMICS engineering documentation.

Q3: How does the sinewave filter improve network stability in multi-drive installations?
A: In installations with multiple SINAMICS drives sharing a common PROFINET segment, motor-generated EMI from unfiltered drive outputs can couple into Ethernet cabling and degrade network signal quality. The 6RX1800-0AS50 eliminates high-frequency voltage harmonics at each drive output, reducing the cumulative EMI burden on the network and improving overall communication reliability across all connected devices.

Q4: What warranty and pre-shipment testing does ZYPLC provide for the 6RX1800-0AS50?
A: All 6RX1800-0AS50 units supplied by ZYPLC are covered by a warranty terms confirmed during quotation from the date of shipment. Each unit undergoes pre-shipment inspection including visual examination, insulation resistance testing, and functional verification to ensure it meets Siemens specifications before dispatch. Availability is confirmed via RFQ for shipment arranged after confirmation to global destinations.