Siemens
Siemens 6SE6440-2AD31-1CA1 Industrial Network Interface for Micromaster 440 Systems
Siemens RFQ support for Communication Gateway. Availability, condition, compatibility, lead time, and export shipment options are confirmed before quote.
Siemens
Siemens RFQ support for Communication Gateway. Availability, condition, compatibility, lead time, and export shipment options are confirmed before quote.
Full part number, suffix, photos, and installed-system context are checked before quotation.
New, refurbished, tested, or compatible replacement options are confirmed through RFQ.
Packing, courier route, destination, and follow-up channel are aligned before shipment.
Technical Details
Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.
The Siemens 6SE6440-2AD31-1CA1 is a high-performance variable frequency drive from the Micromaster 440 series, engineered with native PROFIBUS-DP communication capability that positions it as a critical industrial network interface node in modern smart factory architectures. Rated at 11 kW (3-phase, 400 V AC), this drive does far more than regulate motor speed — it serves as a real-time data gateway between field-level devices and upper-level control and monitoring systems, enabling seamless protocol conversion, live process visibility, and remote diagnostic access across the entire automation chain.
In today’s connected manufacturing environment, the ability to transmit accurate, low-latency data from a drive to a SCADA platform or DCS backbone is no longer optional — it is foundational. The 6SE6440-2AD31-1CA1 fulfills this role by integrating directly into PROFIBUS-DP networks at up to 12 Mbit/s, delivering cyclic process data exchange with deterministic timing that satisfies the demands of high-speed production lines, conveyor systems, pump stations, compressor banks, and HVAC automation.
| Parameter | Specification |
|---|---|
| SKU / Part Number | 6SE6440-2AD31-1CA1 |
| Brand / Series | Siemens Micromaster 440 |
| Communication Protocol | PROFIBUS-DP (EN 50170) |
| Network Transmission Speed | Up to 12 Mbit/s |
| Interface Type | 9-pin D-Sub PROFIBUS connector |
| Network Compatibility | PROFIBUS-DP V0 / V1, GSD file supported |
| Power Rating | 11 kW, 3-phase 380–480 V AC |
| Output Current | 25 A |
| Control Mode | V/f, Flux Current Control (FCC), Sensorless Vector |
| System Application | PLC, SCADA, DCS, HMI, Remote I/O, Edge Gateway |
| Compatible Controllers | Siemens S7-300, S7-400, S7-1500, S7-1200 |
| Product Type | Communication Gateway / Variable Frequency Drive |
| Origin | Germany |
| Warranty | warranty terms confirmed during quotation |
| Stock Status | RFQ Available – shipment arranged after confirmation |
Understanding the 6SE6440-2AD31-1CA1 requires viewing it not as a standalone drive, but as an active participant in a layered industrial data architecture. At the field level, process sensors — including pressure transmitters, flow meters, and temperature probes — feed analog or digital signals into remote I/O modules such as the Siemens ET 200S or ET 200M distributed I/O stations. These stations aggregate field signals and relay them upstream via PROFIBUS-DP, the same network backbone on which the 6SE6440-2AD31-1CA1 operates as a slave device.
The drive receives speed setpoints, direction commands, and parameter write requests from a Siemens S7-300 or S7-1500 PLC acting as the PROFIBUS master. In return, it cyclically transmits actual output frequency, motor current, DC bus voltage, fault codes, and drive status words back to the controller — all within a single PROFIBUS telegram cycle. This bidirectional, real-time data exchange eliminates the need for separate analog wiring between the controller and the drive, reducing installation complexity and improving signal integrity across long cable runs in large industrial facilities.
At the supervisory level, a Siemens WinCC SCADA system or a third-party HMI panel — connected to the S7 PLC via Industrial Ethernet (PROFINET or TCP/IP) — visualizes the drive’s operational parameters in real time. Operators can monitor motor load trends, track energy consumption, and configure alarm thresholds directly from the control room. When a fault condition occurs — such as an overcurrent trip or a communication timeout — the SCADA system receives the fault code from the 6SE6440-2AD31-1CA1 within milliseconds, triggering alarm notifications and logging the event for post-incident analysis.
For facilities deploying edge computing strategies, an industrial edge gateway (such as the Siemens SINEMA Remote Connect or a third-party IIoT gateway) can bridge the PROFIBUS segment to cloud-based analytics platforms. This enables predictive maintenance workflows where drive vibration signatures, thermal trends, and load profiles are analyzed over time to forecast bearing wear or winding degradation before a failure occurs. The 6SE6440-2AD31-1CA1’s rich diagnostic data set — accessible via the Siemens AOP30 Advanced Operator Panel or through PROFIBUS acyclic services — makes it an ideal data source for such IIoT applications.
In multi-drive installations, the 6SE6440-2AD31-1CA1 coexists on the same PROFIBUS segment alongside other Micromaster 440 units, Siemens G120 drives with CBE20 PROFIBUS option boards, and Siemens S120 servo drive systems. Each device is assigned a unique PROFIBUS node address (1–125), and the PLC master polls all nodes within a single bus cycle. This architecture supports coordinated multi-axis motion, synchronized conveyor control, and load-sharing pump configurations without requiring additional communication hardware.
One of the most persistent challenges in legacy and transitional manufacturing environments is data isolation — the condition where field devices operate in functional silos, unable to share process data with controllers, historians, or enterprise systems. The 6SE6440-2AD31-1CA1 directly addresses this problem by providing a standardized PROFIBUS-DP interface that integrates the drive into the plant’s existing communication infrastructure without requiring proprietary middleware or custom protocol converters.
Protocol unification is achieved natively: the drive’s built-in PROFIBUS interface speaks the same cyclic and acyclic communication language as the PLC master, eliminating the need for external gateways or signal converters between the drive and the controller. In plants where older drives communicate only via analog 4–20 mA signals or hardwired digital I/O, replacing them with the 6SE6440-2AD31-1CA1 immediately elevates the data richness available to the control system — from a single speed feedback signal to dozens of real-time parameters including torque, power factor, and fault history.
Remote monitoring and diagnostics become straightforward once the drive is integrated into the PROFIBUS network. Maintenance engineers can read drive parameters, reset faults, and adjust PID setpoints remotely from the SCADA workstation or via a VPN-connected laptop — without physically accessing the drive cabinet. This capability is particularly valuable in hazardous environments, unmanned pump stations, or geographically distributed facilities where on-site intervention is costly and time-consuming.
Production line transparency is enhanced by the drive’s ability to report energy consumption data in real time. When integrated with a Siemens SENTRON PAC power monitoring device or an energy management system, the 6SE6440-2AD31-1CA1 contributes to plant-wide energy audits and ISO 50001 compliance reporting. Operators gain visibility into motor efficiency curves, identify underloaded or overloaded drives, and optimize process parameters to reduce energy waste.
System scalability is inherent in the PROFIBUS architecture. Adding a new drive to an existing PROFIBUS segment requires only assigning a node address and loading the drive’s GSD file into the PLC engineering tool (Siemens TIA Portal or STEP 7). No rewiring, no new communication hardware, and no changes to the existing network topology are required. This plug-and-participate design philosophy makes the 6SE6440-2AD31-1CA1 an ideal choice for phased plant expansions and capacity upgrades.
Every unit supplied by ZYPLC undergoes pre-shipment functional testing, including power-on verification, communication interface check, and parameter integrity validation. All products are covered by a warranty terms confirmed during quotation from the date of shipment, with availability confirmed by RFQ availability ensuring rapid delivery to support urgent maintenance and project timelines.
Q1: What is the maximum PROFIBUS-DP transmission speed supported by the 6SE6440-2AD31-1CA1, and does network cable length affect latency?
The 6SE6440-2AD31-1CA1 supports PROFIBUS-DP transmission speeds from 9.6 kbit/s up to 12 Mbit/s. At 12 Mbit/s, the maximum cable segment length is 100 meters; at lower speeds such as 1.5 Mbit/s, segments can extend to 200 meters. Bus cycle times at 12 Mbit/s with a typical 32-node network are well under 5 milliseconds, making the drive suitable for time-critical control loops. Repeaters can be used to extend network reach without compromising deterministic timing.
Q2: Is the 6SE6440-2AD31-1CA1 compatible with Siemens TIA Portal and STEP 7 engineering environments?
Yes. The drive is fully compatible with both Siemens STEP 7 (for S7-300/400 systems) and TIA Portal (for S7-1200/1500 systems). Integration is performed by importing the drive’s GSD file into the hardware configuration, assigning a PROFIBUS node address, and mapping the process data objects (PDOs) to PLC data blocks. Siemens provides standard GSD files for all Micromaster 440 variants, and ZYPLC can supply configuration documentation upon request.
Q3: Can the 6SE6440-2AD31-1CA1 operate on a mixed PROFIBUS network alongside non-Siemens devices?
Yes. PROFIBUS-DP is an open international standard (EN 50170 / IEC 61158), and the 6SE6440-2AD31-1CA1 is fully interoperable with any PROFIBUS-DP master or slave device that conforms to the standard, regardless of manufacturer. It can coexist on the same bus segment with third-party PLCs, HMI panels, remote I/O modules, and instrumentation devices. The drive’s GSD file provides all necessary configuration data for non-Siemens masters.
Q4: What warranty and pre-shipment testing does ZYPLC provide for the 6SE6440-2AD31-1CA1?
All units supplied by ZYPLC are covered by a warranty terms confirmed during quotation from the date of shipment. Prior to dispatch, each unit undergoes a pre-shipment inspection that includes power-on testing, PROFIBUS communication interface verification, and parameter default confirmation. Availability is confirmed via RFQ for same-day or next-day dispatch. For project quantities or urgent requirements, please contact our team at +86 19859288691 or plc.sales@zyplc.com for availability confirmation and lead time.
ZYPLC handles Siemens 6SE6440-2AD31-1CA1 Industrial Network Interface for Micromaster 440 Systems as a quote-based industrial automation spare part. Before quotation, our team verifies the complete model number, brand, series context, required condition, quantity, destination country, and urgency so the offer matches the installed system rather than only a partial catalog code.
| Model / SKU | 6SE6440-2AD31-1CA1 |
|---|---|
| Brand / Series | Siemens / Micromaster 440 |
| RFQ details needed | Complete part number, suffix or revision, quantity, target country, preferred condition, urgency, and photos or nameplate when available. |
| Availability basis | Availability, condition, lead time, and export shipment options are confirmed by RFQ. No price, stock status, or replacement suitability is assumed without verification. |
Industrial control parts often depend on firmware, revision, communication option, voltage range, rack type, or regional suffix. Please keep suffixes such as -00, -01, -CN, -JP, -CA, or similar revision marks in the RFQ message so compatibility can be checked against the existing PLC, DCS, drive, HMI, or machinery protection system.
Availability is confirmed by RFQ. Send the full model number, required quantity, condition requirement, destination country, and urgency so our sourcing team can check suitable supply options.
Yes. For PLC, DCS, drive, HMI, robotics, and machinery monitoring parts, suffixes and revisions matter. Photos, nameplates, firmware notes, or installed-system details help reduce mismatch risk.
Yes. ZYPLC supports quote-based sourcing for current, discontinued, and legacy industrial automation spares through verified industrial supply channels, with condition and lead time confirmed before quote.
Where applicable, parts are reviewed, packed for export, and prepared for shipment after RFQ confirmation. Testing scope, warranty terms, and shipment method are confirmed during quotation.