Skip to main content

Siemens

Siemens A5E42881719 Power Unit for S120

Siemens A5E42881719 SINAMICS S120 Power Unit Module. Boost drive efficiency, cut energy waste. warranty terms confirmed during quotation, tested before shipment where applicable. RFQ: zyplc.com

SKUA5E42881719 BrandSiemens TypePower Unit Module SeriesSINAMICS OriginDE CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Siemens A5E42881719 Power Unit for S120 Automation

The Siemens A5E42881719 is a SINAMICS S120 series Power Unit Module engineered for high-efficiency drive control in demanding industrial automation environments. Designed to minimize reactive power losses and maximize motor utilization, this module plays a central role in reducing operating load across multi-axis servo and vector drive systems. Whether deployed in CNC machining centers, packaging lines, press automation, or material handling conveyors, the A5E42881719 delivers stable DC bus power with low harmonic distortion — directly contributing to measurable reductions in facility energy costs and improved production line throughput.

Product Specification Table

Parameter Specification
SKU / Part Number A5E42881719
Brand / Series Siemens SINAMICS S120
Module Type Power Unit Module (Active Line / Motor Module compatible)
Typical Input Voltage 3-phase AC 380–480 V (±10%)
Drive Efficiency Class IE2 / IE3 compatible motor drive support
Compatible Systems SINAMICS S120 Drive System, CU320-2 Control Unit
Application Environment CNC, Servo Press, Packaging, Conveyor, Crane Automation
Energy Recovery Regenerative braking energy feedback via Active Line Module
Communication Protocol DRIVE-CLiQ, PROFINET, PROFIBUS-DP
Warranty warranty terms confirmed during quotation — Tested & availability subject to RFQ confirmation

System Compatibility and Application

The A5E42881719 Power Unit Module operates as the core power conversion stage within the SINAMICS S120 modular drive architecture. In a typical energy-optimized production cell, it works in close coordination with the SINAMICS S120 Active Line Module (ALM) to enable regenerative energy feedback — capturing braking energy from deceleration cycles and returning it to the shared DC bus rather than dissipating it as heat. This alone can reduce net operating load by Actual operating results depend on the installed system, load profile, and commissioning parameters.

The module interfaces directly with the CU320-2 DP / CU320-2 PN Control Unit via DRIVE-CLiQ, enabling real-time torque, speed, and flux control with sub-millisecond response. Paired with SINAMICS S120 Motor Modules (single-axis or double-axis booksize format), the A5E42881719 supports coordinated multi-axis motion with synchronized energy load distribution — preventing peak demand spikes that inflate electricity costs.

For condition monitoring and power quality analysis, the system integrates seamlessly with SENTRON PAC3200 or PAC4200 Power Monitoring Devices, which capture real-time kWh consumption, power factor, and harmonic data at the drive level. This data feeds into SIMATIC Energy Suite running on a SIMATIC S7-1500 PLC, enabling closed-loop maintenance planning where the controller can dynamically adjust drive setpoints based on live consumption feedback.

On the field I/O side, SIMATIC ET 200SP distributed I/O modules collect sensor signals from motor temperature probes, vibration sensors, and current transducers — feeding predictive maintenance data back to the control layer. The SIMATIC HMI TP1200 Comfort Panel provides operators with a real-time energy dashboard, displaying per-axis power consumption, efficiency trends, and alarm states without requiring separate SCADA infrastructure.

For facilities running mixed drive environments, the A5E42881719 supports PROFIBUS-DP and PROFINET IO communication, allowing it to coexist with legacy SINAMICS G120 variable frequency drives on pump and fan circuits — where simple V/f control delivers significant operational stability on variable-torque loads. The combination of S120 servo precision and G120 energy-optimized scalar control across a single network backbone reduces both wiring complexity and commissioning time.

Maintenance and Replacement Notes

In automotive body-in-white welding lines, the A5E42881719 supports high-dynamic servo axes on spot-welding robots and transfer systems. By enabling regenerative energy recovery during robot deceleration phases, facilities report 20–25% reductions in drive-related operating load per shift. The shared DC bus architecture means braking energy from one axis is immediately available to accelerate another — eliminating the need for braking resistors and reducing thermal load on the control cabinet.

In packaging and filling lines, the module’s precise torque control reduces mechanical stress on gearboxes and couplings, extending mean time between maintenance (MTBM) and reducing unplanned downtime. Fewer stops mean better OEE (Overall Equipment Effectiveness) and lower energy cost per unit produced. The DRIVE-CLiQ diagnostic interface continuously monitors winding temperature, bearing condition, and encoder integrity — enabling condition-based maintenance scheduling rather than fixed-interval overhauls.

For press and stamping applications, the A5E42881719’s fast current control loop supports high peak torque demands during forming strokes while maintaining low average power draw during dwell phases. This load-profile optimization, combined with Active Line Module regeneration, can reduce peak demand charges on industrial electricity tariffs — a significant cost lever for high-tonnage press shops.

All units supplied by ZYPLC are sourced from verified supply channels, subjected to functional power-on testing, and covered by a warranty terms confirmed during quotation. Stock is available for shipment arranged after confirmation via DHL Express or FedEx International Priority, with full export documentation for cross-border logistics.

Product Sourcing FAQ

Q1: How much energy can the A5E42881719 save compared to a standard non-regenerative drive module?
In high-cycle servo applications with frequent acceleration/deceleration, regenerative configurations using the A5E42881719 with an Active Line Module typically recover Actual operating results depend on the installed system, load profile, and commissioning parameters. Actual savings depend on cycle time, inertia ratio, and load profile. ZYPLC can assist with energy audit data review to estimate site-specific savings.

Q2: Is the A5E42881719 compatible with existing SINAMICS S120 booksize infrastructure?
Yes. The A5E42881719 is designed for the SINAMICS S120 booksize platform and is compatible with standard S120 Motor Modules, Control Units (CU320-2 series), and DRIVE-CLiQ topology. Firmware compatibility should be verified against your CU320-2 firmware version prior to installation.

Q3: What is the recommended replacement or upgrade path if this module fails in production?
ZYPLC maintains tested replacement stock of the A5E42881719 and compatible S120 Power Unit variants. For critical production lines, we recommend keeping one spare unit on-site. Our team can provide cross-reference support for alternative Siemens part numbers within the S120 family if the exact SKU is temporarily unavailable.

Q4: What does the warranty terms confirmed during quotation cover, and how is the testing process conducted?
Every A5E42881719 unit shipped by ZYPLC undergoes functional power-on testing, DC bus voltage verification, and DRIVE-CLiQ communication checks before dispatch. The warranty terms confirmed during quotation covers manufacturing defects and functional failures under normal operating conditions. DOA (Dead on Arrival) units are replaced or refunded within the agreed RMA process. Contact our technical team for warranty claim procedures.