Yokogawa
Yokogawa AS-S9032AL-0 Industrial Network Interface for Centum VP Systems
Yokogawa AS-S9032AL-0 (DP97*B) Industrial Network Interface for Centum VP DCS. Protocol gateway, real-time data, SCADA integration. 12-month warranty. RFQ.
Yokogawa
Yokogawa AS-S9032AL-0 (DP97*B) Industrial Network Interface for Centum VP DCS. Protocol gateway, real-time data, SCADA integration. 12-month warranty. RFQ.
The Yokogawa AS-S9032AL-0 (DP97*B) is a high-performance industrial network interface card engineered for seamless data communication within Yokogawa’s Centum VP Distributed Control System (DCS) architecture. Designed to serve as the critical connectivity backbone between field devices, PLC controllers, remote I/O modules, HMI stations, SCADA platforms, and upper-level MES/ERP systems, this display processor card ensures deterministic, low-latency data flow across the entire automation hierarchy of a modern smart factory.
In today’s industrial landscape, the integrity of the data chain — from signal acquisition at the sensor level all the way to real-time visualization on SCADA dashboards — depends entirely on the reliability of the network interface layer. The AS-S9032AL-0 fulfills this role within the Centum VP ecosystem, providing stable protocol handling, robust communication throughput, and seamless integration with Yokogawa’s proprietary Vnet/IP industrial Ethernet backbone.
| Attribute | Specification |
|---|---|
| SKU | DP97*B / AS-S9032AL-0 |
| Brand | YOKOGAWA |
| Series | Centum VP / Centum CS 3000 |
| Product Type | Industrial Network Interface / Display Processor Card |
| Communication Protocol | Vnet/IP (Yokogawa Industrial Ethernet), OPC-UA compatible gateway path |
| Interface Type | Backplane bus interface, Ethernet port (RJ-45) |
| Transmission Capability | High-speed deterministic data transfer for real-time process control |
| Network Compatibility | Centum VP DCS network, SCADA integration, HMI connectivity |
| System Application | Process automation, smart factory, remote monitoring, SCADA/HMI integration |
| Origin | Japan |
| Warranty | 12-Month Warranty |
| Shipping | DHL / FedEx global express, full export compliance |
Within a fully integrated Centum VP control network, the AS-S9032AL-0 (DP97*B) acts as the central data processing node that bridges field-level instrumentation with supervisory control layers. The data flow begins at the sensor and transmitter level — pressure transducers, flow meters, and temperature sensors feed analog and digital signals into Yokogawa CENTUM VP Field Control Stations (FCS) such as the AFV10D or AFV30D, where raw process values are digitized and conditioned.
These conditioned signals are then routed through the Vnet/IP backbone, where the AS-S9032AL-0 handles display processing and network arbitration. Alongside it, Yokogawa AIP588 and AIP578 I/O interface modules manage the physical signal termination, while Yokogawa ACM11 communication modules extend connectivity to remote I/O clusters deployed across the plant floor. For installations requiring PROFIBUS DP or FOUNDATION Fieldbus integration, the Yokogawa ALF111 fieldbus communication module works in tandem with the AS-S9032AL-0 to bridge legacy field protocols into the Centum VP data highway.
At the HMI and SCADA layer, Yokogawa’s CENTUM VP Human Interface Station (HIS) — running on dedicated operator workstations — receives real-time process data processed through the AS-S9032AL-0 network interface. This enables operators to monitor live process variables, acknowledge alarms, and execute control commands with sub-second response times. For plants integrating third-party SCADA platforms such as Wonderware, iFIX, or Ignition, the AS-S9032AL-0 supports OPC-UA gateway paths, ensuring interoperability without compromising data integrity.
In multi-loop control architectures, the AS-S9032AL-0 also coordinates with Yokogawa STARDOM FCN/FCJ remote process controllers deployed at satellite skids or remote wellheads, aggregating their data streams into the central Centum VP historian. Variable frequency drives (VFDs) and motor control centers connected via Yokogawa RM35006 or compatible PROFIBUS-linked drives also report operational data — speed, torque, fault codes — through this network interface layer, enabling predictive maintenance workflows and energy optimization analytics at the SCADA level.
One of the most persistent challenges in brownfield industrial facilities is the coexistence of multiple, incompatible communication protocols — legacy serial RS-485 Modbus RTU devices sitting alongside modern Ethernet-based PROFINET or EtherNet/IP nodes, with no unified data pathway to the control room. The Yokogawa AS-S9032AL-0 (DP97*B) addresses this directly within the Centum VP framework by serving as the protocol-aware network interface that normalizes data from heterogeneous sources into a unified Vnet/IP data stream.
For plants struggling with data silos — where field device data never reaches the SCADA historian, or where remote skids operate in isolation from the central DCS — the AS-S9032AL-0 provides the network backbone that eliminates these gaps. Its integration with Yokogawa’s Exaquantum plant information management system (PIMS) enables continuous data logging, KPI tracking, and production reporting without manual data extraction. Operators gain full production line transparency: every valve position, pump status, and flow rate is visible in real time on the HIS operator console.
Remote diagnostics capabilities are equally critical. Through the Centum VP network, maintenance engineers can remotely interrogate field device health, review alarm histories, and perform loop checks without physical site visits — dramatically reducing mean time to repair (MTTR) and unplanned downtime. System expansion is equally straightforward: additional FCS nodes, remote I/O racks, or new process units can be integrated into the existing Centum VP network without disrupting live production, thanks to the modular architecture that the AS-S9032AL-0 supports.
Every unit of the Yokogawa AS-S9032AL-0 (DP97*B) available through ZYPLC undergoes pre-shipment functional testing to verify communication integrity, backplane interface continuity, and network protocol handshake performance. Stock is maintained for immediate dispatch, with DHL and FedEx express options available for global delivery. All units are covered by a 12-month warranty, with full export documentation and compliance certification provided.
Q1: What communication protocols does the Yokogawa AS-S9032AL-0 (DP97*B) support?
The AS-S9032AL-0 operates natively on Yokogawa’s Vnet/IP industrial Ethernet protocol within the Centum VP DCS architecture. It supports OPC-UA gateway integration for third-party SCADA and MES connectivity, and can interface with PROFIBUS DP and FOUNDATION Fieldbus segments through compatible Yokogawa communication modules such as the ALF111.
Q2: How does this card ensure network stability in high-noise industrial environments?
The AS-S9032AL-0 is designed to Yokogawa’s industrial-grade hardware standards, with EMI shielding and deterministic communication protocols that maintain data integrity in electrically noisy plant environments. The Vnet/IP backbone provides redundant communication paths, ensuring continuous data flow even in the event of a single network segment failure.
Q3: Can the AS-S9032AL-0 be integrated into an existing Centum CS 3000 system?
Yes. The AS-S9032AL-0 is compatible with both Centum VP and legacy Centum CS 3000 architectures, making it suitable for system migration and expansion projects. It supports hot-standby redundancy configurations, allowing integration without production shutdown.
Q4: What does the 12-month warranty cover, and how is pre-shipment testing conducted?
All AS-S9032AL-0 units supplied by ZYPLC are covered by a 12-month warranty against manufacturing defects and communication failures. Pre-shipment testing includes backplane interface verification, Vnet/IP protocol handshake testing, and visual inspection for component integrity. Units failing any test criterion are quarantined and not dispatched.
© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | [email protected]