Skip to main content

Yokogawa

YOKOGAWA ATA4D-00 S2 Industrial Network Interface for CENTUM Systems

YOKOGAWA ATA4D-00 S2 Analog Input Module for CENTUM DCS. Protocol gateway, real-time data, SCADA integration. 12-month warranty. RFQ: zyplc.com

SKUATA4D-00 S2 BrandYokogawa TypeAnalog Input Module SeriesCENTUM OriginJP CategorySensors & I/O
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

YOKOGAWA ATA4D-00 S2: Industrial Data Link and Smart Factory Connectivity for CENTUM Systems

The YOKOGAWA ATA4D-00 S2 is a high-precision Analog Input Module engineered for seamless integration within the CENTUM Distributed Control System (DCS) architecture. Designed to serve as a critical node in the industrial data chain, this module bridges field-level instrumentation — including pressure transmitters, temperature sensors, flow meters, and 4–20 mA signal devices — with the upper-layer control and monitoring infrastructure of modern smart factories. Whether deployed in oil and gas processing, chemical plants, power generation facilities, or advanced manufacturing lines, the ATA4D-00 S2 delivers stable, low-latency analog signal acquisition that forms the backbone of real-time process visibility.

In today’s connected industrial environment, the integrity of the data link between field devices and supervisory systems is non-negotiable. The ATA4D-00 S2 fulfills this role by converting raw analog signals into structured digital data that flows upward through the CENTUM VP or CENTUM CS 3000 controller network, enabling SCADA platforms and HMI workstations to display live process values, trigger alarms, and execute automated control logic without interruption.

Network Communication Table

Parameter Specification
SKU ATA4D-00 S2
Brand YOKOGAWA
Series CENTUM DCS
Module Type Analog Input Module
Signal Protocol 4–20 mA Analog / HART-compatible field wiring
Communication Interface CENTUM V-net / ER Bus backplane communication
Transmission Capability Multi-channel real-time analog data acquisition
Network Compatibility CENTUM VP, CENTUM CS 3000, Vnet/IP
System Application DCS, SCADA, HMI, PLC Gateway, Remote I/O
Origin Japan
Warranty 12-Month Warranty
Pre-shipment Testing Functionally tested before dispatch
Availability In Stock — Ready to Ship

Connected Automation Data Flow

The ATA4D-00 S2 sits at the heart of a layered industrial communication architecture. At the field level, analog sensors — such as YOKOGAWA EJA110E differential pressure transmitters or YTA710 temperature transmitters — feed 4–20 mA signals directly into the ATA4D-00 S2 input channels. These signals are digitized and passed through the CENTUM V-net backplane to the YOKOGAWA AFV10D Field Control Station, where the process controller executes PID loops and interlock logic based on the acquired values.

From the Field Control Station, structured process data travels over the Vnet/IP Ethernet backbone — YOKOGAWA’s high-speed, deterministic plant network — to the YOKOGAWA HIS (Human Interface Station), where operators monitor live trends, acknowledge alarms, and issue setpoint changes through the CENTUM VP HMI environment. Simultaneously, the same data stream is made available to the plant’s SCADA gateway layer, where systems such as the YOKOGAWA Exaquantum Plant Information Management System (PIMS) archive historical process data for performance analysis, regulatory compliance, and predictive maintenance workflows.

For facilities integrating third-party PLCs or remote I/O nodes — such as YOKOGAWA FA-M3 range-free multi-layer controllers or Modbus RTU-based remote terminal units — the ATA4D-00 S2 data can be bridged through YOKOGAWA MW100 Data Acquisition Units or dedicated protocol gateways, enabling unified data visibility across heterogeneous control networks. Variable frequency drives (VFDs) and motor control centers connected via PROFIBUS DP or DeviceNet can also feed status and speed feedback into the CENTUM system through compatible I/O modules, creating a fully integrated drive-to-DCS data path.

Edge computing nodes — such as industrial IoT gateways running OPC-UA servers — can subscribe to the CENTUM data highway and forward normalized process data to cloud-based MES or ERP platforms, completing the digital thread from sensor to enterprise. The ATA4D-00 S2 is therefore not merely an input card; it is the origination point of a data flow that spans the entire smart factory stack.

Solving Data Isolation in Industrial Sites

One of the most persistent challenges in legacy and hybrid industrial environments is data isolation — the condition where field instruments, PLCs, DCS controllers, and SCADA systems operate in silos, unable to share process information in real time. The YOKOGAWA ATA4D-00 S2 directly addresses this problem by providing a standardized, high-integrity analog input interface that integrates natively with the CENTUM DCS communication fabric.

In plants where multiple control platforms coexist — for example, a CENTUM VP DCS managing the main process alongside standalone YOKOGAWA FA-M3 PLCs controlling auxiliary utilities — the ATA4D-00 S2 ensures that analog field data is captured at the source with full engineering unit scaling and channel diagnostics, eliminating the need for manual data transcription or secondary signal conditioning equipment. This reduces wiring complexity, minimizes signal degradation, and shortens commissioning time.

For remote monitoring and diagnostics, the CENTUM VP system’s built-in alarm management and event logging capabilities — fed by accurate analog data from modules like the ATA4D-00 S2 — enable maintenance teams to detect process deviations, diagnose instrument faults, and initiate corrective actions without dispatching personnel to the field. Integration with YOKOGAWA PRM (Plant Resource Manager) further extends remote diagnostics to HART-enabled field devices, allowing valve positioner feedback, transmitter self-diagnostics, and loop integrity checks to be performed from the control room.

Production line transparency is achieved through the combination of real-time analog data acquisition, historian archiving via Exaquantum, and dashboard visualization on the CENTUM HIS. Plant managers gain a live view of key performance indicators — yield, energy consumption, equipment utilization — derived directly from the analog signals captured by the ATA4D-00 S2 and its companion modules. System expansion is equally straightforward: additional ATA4D-00 S2 modules can be inserted into available CENTUM I/O nest slots without system shutdown, supporting phased capacity growth aligned with production demands.

Industrial Connectivity FAQ

Q1: What communication protocols does the YOKOGAWA ATA4D-00 S2 support?
The ATA4D-00 S2 is designed for native integration within the YOKOGAWA CENTUM DCS platform, communicating over the V-net and Vnet/IP backplane protocols. At the field level, it accepts standard 4–20 mA analog signals and is compatible with HART-enabled instruments, allowing device diagnostics and configuration data to be overlaid on the analog signal without additional wiring.

Q2: How does the ATA4D-00 S2 ensure network stability and data integrity in demanding industrial environments?
The module is built to YOKOGAWA’s industrial-grade hardware standards, featuring noise immunity, redundant power input compatibility, and channel-level diagnostics that detect open-circuit, short-circuit, and out-of-range conditions. The CENTUM DCS architecture supports controller and network redundancy, ensuring that a single module or cable fault does not interrupt plant-wide data acquisition or control.

Q3: Can the ATA4D-00 S2 be integrated with third-party SCADA or HMI systems outside the CENTUM environment?
Yes. Through YOKOGAWA’s OPC-DA and OPC-UA server interfaces available on the CENTUM VP platform, process data acquired by the ATA4D-00 S2 can be published to any OPC-compliant SCADA or HMI system, including Wonderware, iFIX, Ignition, and WinCC. This enables hybrid architectures where CENTUM handles primary control while a third-party SCADA provides enterprise-level visualization and reporting.

Q4: What warranty and pre-shipment testing does ZYPLC provide for the ATA4D-00 S2?
Every YOKOGAWA ATA4D-00 S2 unit supplied by ZYPLC is covered by a 12-month warranty and undergoes functional testing prior to dispatch. Our quality control process verifies channel integrity, communication handshake with the CENTUM backplane, and signal accuracy across the full input range, ensuring that the module arrives ready for installation and commissioning without delays.

© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | [email protected]