Bosch Rexroth 1070068007-102 SERCOS Interface for DC102 Systems: Industrial Data Link for Smart Factory Drive Networks
The Bosch Rexroth 1070068007-102 is a SERCOS (Serial Real-time Communication System) Terminating Module engineered for the DC102 and IndraDrive series drive platforms. As a critical node in the industrial communication chain, this module ensures signal integrity and network stability across high-speed fiber-optic SERCOS rings connecting CNC controllers, servo drives, and motion control systems. In modern smart factory environments where microsecond-level synchronization between drives and controllers determines production quality, the 1070068007-102 plays an indispensable role in maintaining the closed-loop data path that keeps every axis in perfect coordination.
Compatibility & Integration Notes
| Parameter |
Specification |
| SKU / Part Number |
1070068007-102 (D-64711) |
| Brand / Manufacturer |
Bosch Rexroth |
| Series |
DC102 / IndraDrive |
| Communication Protocol |
SERCOS I / SERCOS II (Serial Real-time Communication System) |
| Interface Type |
Fiber-Optic Ring Termination |
| Transmission Medium |
Fiber-Optic Cable (POF / HCS) |
| Network Topology |
Ring (SERCOS Ring Bus) |
| System Compatibility |
IndraDrive, IndraDrive C, IndraDrive M, DKC Series, IndraControl |
| Application |
CNC Motion Control, Servo Drive Networks, Industrial Automation |
| Country of Origin |
Germany (DE) |
| Warranty |
warranty terms confirmed during quotation |
| Shipping |
Global DHL / FedEx Express |
Connected Automation Data Flow
In a fully integrated IndraDrive motion network, the 1070068007-102 SERCOS Terminating Module anchors the end of the fiber-optic ring, reflecting the SERCOS telegram back through the loop to the master controller. This ring architecture begins at the IndraControl VPP 40 or IndraControl L45 CNC/PLC controller, which generates the SERCOS master telegram at cycle times as low as 62.5 µs. The telegram travels through each IndraDrive HCS02 and IndraDrive HCS01 servo drive node in sequence — each drive reading its command data and writing back actual position, velocity, and status values in real time.
At the final drive node in the ring — often an IndraDrive C HCS02.1E or IndraDrive M HMS01 multi-axis supply module — the 1070068007-102 terminates the optical signal, preventing reflection loss and ensuring the ring closes cleanly. Without a properly functioning terminating module, the SERCOS ring cannot achieve phase 4 (cyclic communication), and all connected drives will fault out, halting the production line.
Upstream, the SERCOS network data is aggregated by the IndraControl VPP platform and forwarded via Ethernet/IP or PROFIBUS to the plant-level SCADA system or IndraView HMI operator panels, where production engineers monitor axis positions, torque loads, and drive temperatures in real time. Remote I/O modules such as the Rexroth Inline I/O system feed digital and analog field signals into the IndraLogic PLC, which coordinates motion sequences with the SERCOS drive network through the IndraControl runtime environment.
For multi-axis gantry systems or synchronized press lines, the DKC03.3 and DKC11.3 drive controllers within the same SERCOS ring rely on the terminating module to maintain phase-locked synchronization across all axes. Any interruption in the ring — caused by a missing or failed terminating module — immediately triggers a collective drive fault across the entire axis group, underscoring the criticality of the 1070068007-102 in maintaining production continuity.
Edge gateway devices such as the Rexroth IndraGate can bridge SERCOS ring data to higher-level OPC-UA or MQTT streams for IIoT analytics platforms, enabling predictive maintenance dashboards to track drive health metrics sourced directly from the SERCOS cyclic data channel.
Solving Data Isolation in Industrial Sites
One of the most persistent challenges in legacy industrial installations is protocol fragmentation — machines running SERCOS I alongside newer PROFINET or EtherCAT segments, with no unified data path to the SCADA layer. The Bosch Rexroth 1070068007-102 addresses the SERCOS ring integrity problem at its root: by providing a clean, low-loss optical termination, it ensures that the SERCOS master can reliably poll all drive nodes without communication timeouts or phase degradation.
In plants where production transparency is a priority, a stable SERCOS ring means that every drive’s actual value data — position error, following error, motor temperature, DC bus voltage — is available to the IndraControl runtime at every communication cycle. This data can be logged, trended, and alarmed through the IndraView HMI or forwarded to MES/ERP systems via OPC-UA gateways, eliminating the data silos that previously made drive-level diagnostics impossible without physical access to the control cabinet.
For system integrators expanding an existing IndraDrive installation — adding new axes to a press line or extending a CNC machining cell — the 1070068007-102 must be repositioned to the new end of the ring. This simple reconfiguration, combined with SERCOS address reassignment in the IndraControl engineering tool, allows the network to scale without rewiring or protocol conversion, preserving the existing fiber-optic infrastructure investment.
Remote diagnostics capabilities are further enhanced when the SERCOS ring is stable: drive fault codes, encoder errors, and communication phase failures are immediately visible in the SCADA alarm log, allowing maintenance teams to identify and resolve issues before they escalate to unplanned downtime. The 1070068007-102 is supplied fully tested and verified against Bosch Rexroth factory specifications, with each unit undergoing outgoing inspection to confirm optical signal integrity prior to shipment.
Industrial Connectivity FAQ
Q1: What happens if the SERCOS terminating module is missing or faulty?
Without the 1070068007-102 terminating the fiber-optic ring, the SERCOS master controller cannot complete the ring topology and will fail to advance beyond communication phase 2. All IndraDrive nodes on the ring will report a communication fault and refuse to enable, halting all motion. Replacing or correctly installing the terminating module restores ring continuity and allows normal phase progression to cyclic operation (phase 4).
Q2: Is the 1070068007-102 compatible with both SERCOS I and SERCOS II?
Yes. The DC102 series terminating module supports both SERCOS I (2 Mbit/s, 4 Mbit/s, 8 Mbit/s) and SERCOS II (16 Mbit/s) baud rates, making it compatible with the full range of IndraDrive, DKC, and IndraControl SERCOS master implementations. Baud rate selection is handled by the SERCOS master controller, not the terminating module.
Q3: How does this module contribute to network stability in high-vibration environments?
The 1070068007-102 uses a robust fiber-optic connector interface that is inherently immune to electromagnetic interference (EMI) — a critical advantage in environments with large servo drives, VFDs, and welding equipment operating nearby. The fiber-optic medium eliminates ground loop issues and ensures consistent signal quality regardless of electrical noise on the factory floor.
Q4: What warranty and testing does this unit include?
Every 1070068007-102 supplied by ZYPLC is covered by a warranty terms confirmed during quotation and has undergone pre-shipment functional testing to verify optical signal integrity and connector condition. Units are shipped via DHL or FedEx Express with full tracking, and our technical team is available to support installation and commissioning queries.