Honeywell 8C-TPOX01 51307022-175 wireless module backplane for OneWireless & Experion PKS. Boost plant energy efficiency. Tested, warranty terms confirmed during quotation.

SKU8C-TPOX01 51307022-175 BrandHoneywell TypeWireless Module Backplane SeriesOther series OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Honeywell 8C-TPOX01 51307022-175 Wireless Module for OneWireless Automation

The Honeywell 8C-TPOX01 51307022-175 is a high-performance wireless module backplane engineered for the OneWireless network platform and fully integrated with the Experion PKS distributed control system. Designed for demanding industrial environments, this module enables seamless wireless data acquisition, real-time condition monitoring, and precision control execution — all without the overhead of additional wiring infrastructure. For plant engineers focused on reducing operational energy costs and improving equipment utilization rates, the 8C-TPOX01 51307022-175 delivers a measurable impact across every stage of the automation loop.

In modern manufacturing and process industries, unplanned downtime is rarely caused by a single point of failure — it accumulates across poorly coordinated control loops, underutilized drives, and delayed feedback cycles. The 8C-TPOX01 addresses this by providing a reliable wireless backplane that connects field instruments, sensors, and actuators directly into the Experion PKS control architecture. This eliminates signal latency that would otherwise cause motor drives and variable frequency drives (VFDs) to operate outside their optimal efficiency windows, resulting in unnecessary energy draw and accelerated component wear.

Product Specification Table

Parameter Specification
SKU 8C-TPOX01 51307022-175
Brand Honeywell
Series OneWireless / Experion PKS
Product Type Wireless Module Backplane
Power Consumption Low-power wireless backplane design
Operating Efficiency Optimized for continuous 24/7 industrial operation
Compatible Systems Experion PKS, OneWireless Network, C300 Controller
Application Environment Process plants, refineries, chemical facilities, utilities
Energy Value Reduces wiring overhead; enables real-time energy data feedback
Origin United States
Warranty warranty terms confirmed during quotation
Condition Tested & Verified before shipment

System Compatibility and Application

The 8C-TPOX01 51307022-175 functions as the wireless communication backbone within a broader industrial control architecture. When paired with the Honeywell C300 Controller, it enables closed-loop control strategies that dynamically adjust setpoints based on real-time operating load data. Field devices such as the Honeywell XYR 6000 wireless transmitters feed temperature, pressure, and flow data through the OneWireless network into the backplane, allowing the Experion PKS system to make millisecond-level corrections to process variables.

On the drive side, integration with Honeywell SmartVFD HVAC variable frequency drives allows the control system to modulate motor speed in direct response to process demand — eliminating the fixed-speed operation that accounts for a significant share of industrial unplanned downtime. The 8C-TPOX01 backplane ensures that the communication path between the VFD feedback signals and the C300 controller remains stable and low-latency, which is critical for maintaining tight control over pump and fan systems in energy-intensive facilities.

For I/O expansion and signal conditioning, the Honeywell HART Multiplexer and Series 2MLF I/O modules can be integrated alongside the 8C-TPOX01 to extend the reach of the wireless network into areas where wired infrastructure is impractical. This architecture supports a distributed condition monitoring strategy where power consumption data from individual motor control centers (MCCs) is aggregated at the Experion PKS server level, enabling plant-wide energy dashboards and automated demand response.

The Honeywell Uniformance PHD historian works in conjunction with the OneWireless platform to log energy KPIs over time, providing the data foundation for predictive maintenance models. By analyzing trends in motor current draw, vibration signatures from wireless accelerometers, and process efficiency ratios, maintenance teams can identify degrading equipment before it causes unplanned downtime — a key driver of unplanned downtime in continuous process industries. The Experion PKS Operator Station provides the HMI layer, giving operators a unified view of operating load, equipment status, and alarm management across the entire plant.

Maintenance and Replacement Notes

In a typical refinery or chemical processing facility, the 8C-TPOX01 51307022-175 is deployed to eliminate the communication gaps that cause energy inefficiencies in multi-loop control systems. Consider a scenario where a boiler feed water pump is controlled by a VFD receiving setpoint commands from a remote PID loop. Without a reliable wireless backplane, signal dropouts force the VFD to default to a fixed speed, consuming full rated power regardless of actual process demand. With the 8C-TPOX01 in place, the OneWireless network maintains a continuous, redundant communication path, allowing the VFD to track demand precisely and reduce operating load by Actual operating results depend on the installed system, load profile, and commissioning parameters.

On the production line level, the module supports faster line rhythm optimization by reducing the feedback delay between field sensors and the control system. When a flow transmitter detects a deviation from the target setpoint, the 8C-TPOX01 relays that data to the C300 controller within the OneWireless network’s defined update rate, triggering a corrective action before the deviation propagates downstream. This tight feedback loop reduces product quality losses, minimizes rework energy, and keeps the production line operating at its designed throughput rate.

From a maintenance cost perspective, the wireless architecture enabled by the 8C-TPOX01 eliminates the need for periodic cable inspection and replacement in hazardous or hard-to-reach areas. Reduced physical infrastructure means fewer failure points, lower maintenance labor hours, and a smaller carbon footprint associated with facility upkeep. All units are fully tested prior to shipment and backed by a warranty terms confirmed during quotation, ensuring that replacement modules integrate seamlessly into existing OneWireless networks without recalibration delays that would otherwise interrupt production and waste energy during restart sequences.

Product Sourcing FAQ

Q1: How does the 8C-TPOX01 51307022-175 contribute to measurable operational stability?
By providing a stable, low-latency wireless communication path between field devices and the Experion PKS control system, the 8C-TPOX01 enables precise demand-based control of motors and drives. This eliminates fixed-speed operation and reduces operating load across pump, fan, and compressor systems by enabling VFDs to track actual process demand in real time.

Q2: Is the 8C-TPOX01 compatible with existing Experion PKS and OneWireless installations?
Yes. The 8C-TPOX01 51307022-175 is designed as a direct-fit backplane module for the OneWireless platform and integrates natively with Experion PKS R400 and later versions. It supports standard ISA100.11a wireless protocols, ensuring compatibility with existing field devices and network infrastructure without requiring gateway modifications.

Q3: What is the recommended replacement and testing process for this module?
Each 8C-TPOX01 unit undergoes full functional testing prior to shipment, including communication integrity verification and backplane signal testing. For replacement in live systems, it is recommended to perform a hot-swap during a scheduled maintenance window. The module’s configuration is stored in the Experion PKS server, so re-commissioning time is minimal — typically under 30 minutes for an experienced control system technician.

Q4: What warranty coverage is included, and what does it cover?
All 8C-TPOX01 51307022-175 units are covered by a warranty terms confirmed during quotation from the date of shipment. The warranty covers manufacturing defects, communication failures, and backplane connectivity issues under normal operating conditions. Warranty claims are processed promptly to minimize production downtime, and replacement units are dispatched from available inventory to ensure continuity of your maintenance planning strategy.