Skip to main content

Honeywell

Honeywell C7015A1076 UV Flame Detector for Safeguard

Honeywell C7015A1076 UV flame detector for burner safeguard architecture. RFQ compatibility review ready. warranty terms confirmed during quotation. export shipping options available.

SKUc7015a1076 BrandHoneywell TypeUV Flame Detector SeriesOther series OriginUS CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Honeywell C7015A1076 UV Flame Detector for Safeguard: Control System Coordination and Upstream-Downstream Integration

In modern industrial combustion control systems, flame detection is not an isolated function — it is a critical node within a layered safety and control architecture. The Honeywell C7015A1076 UV Flame Detector is engineered to serve precisely this role: as a reliable, system-integrated sensing element that communicates directly with burner management relays, safety PLCs, and supervisory control platforms. Understanding the C7015A1076 requires viewing it not as a standalone component, but as a functional layer within a complete flame safeguard system designed for continuous, high-availability industrial operation.

The C7015A1076 operates on ultraviolet (UV) flame sensing principles, detecting the UV radiation emitted by hydrocarbon and hydrogen flames. Its output signal interfaces directly with Honeywell’s 7800 Series Burner Management Relay Modules, including the RM7890A1015 and RM7895A1014, which serve as the control-layer decision units for burner sequencing, lockout, and safety shutdown. This tight integration between the flame detector and the relay module forms the backbone of a compliant, IEC 61511-aligned safety instrumented function (SIF) for combustion applications.

Within the control architecture, the C7015A1076 occupies the sensing layer — the lowest tier of the safety loop — feeding verified flame presence or absence data upward to the logic solver layer. The RM7890A1015 relay module processes this signal and executes the appropriate control action: permitting fuel valve opening, initiating trial-for-ignition sequences, or triggering safety lockout. Amplifier modules such as the R7847A1025 Solid-State Rectification Amplifier and the R7849A1023 UV Amplifier extend the system’s signal conditioning capability, allowing the C7015A1076 to operate across varying flame intensities and burner geometries without compromising detection reliability.

At the network and supervisory layer, the burner management system integrates with distributed control systems (DCS) or safety PLCs via hardwired I/O or fieldbus interfaces. The S7800A1001 Keyboard Display Module provides local operator interface capability, enabling engineers to monitor flame signal strength, view diagnostic codes, and adjust operational parameters without requiring a separate HMI terminal. For larger installations, the Q7800A1005 Wiring Subbase simplifies field wiring and ensures consistent terminal layout across multiple burner management modules, reducing installation errors and accelerating commissioning timelines.

Redundancy is a central design consideration in any safety-critical combustion system. The C7015A1076 supports dual-detector configurations where a secondary flame sensor — such as the C7027A1049 Infrared Flame Detector — operates in parallel, providing cross-validation of flame presence. This redundant sensing architecture is particularly valuable in applications where UV signal interference from arc welding, solar radiation, or other UV sources could produce spurious signals. The combination of UV and IR detection technologies within the same control loop significantly reduces the probability of both false trips and undetected flame failures.

Power supply integrity is equally important to system reliability. The 7800 Series relay modules, including the EC7890B1010 Expanded Capability Burner Controller, incorporate internal power management circuits that monitor supply voltage and generate diagnostic alarms when deviations occur. For installations requiring enhanced power conditioning, external 24 VDC regulated supplies with battery backup ensure that the flame safeguard system remains operational during utility power fluctuations — a requirement common in petrochemical, power generation, and district heating applications.

From an engineering and maintenance perspective, the C7015A1076 is designed for straightforward field replacement. Its standardized mounting interface is compatible with the Q7800A1005 wiring subbase and equivalent mounting hardware, allowing technicians to swap detectors during scheduled maintenance windows without rewiring or recalibrating the relay module. This plug-and-play serviceability reduces mean time to repair (MTTR) and supports the long-term maintenance strategies required in facilities operating under continuous production schedules.

Inventory availability and supply chain continuity are critical factors for facilities that depend on Honeywell flame safeguard components. ZYPLC maintains availability subject to RFQ confirmation of the C7015A1076 alongside complementary components including the RM7890A1015, R7847A1025, S7800A1001, and Q7800A1005, enabling complete system builds and rapid replacement sourcing from a single supplier. All units are supplied with a warranty terms confirmed during quotation covering manufacturing defects and functional performance, providing procurement teams and maintenance engineers with documented assurance of component quality.

Product Specification Table

Parameter Specification
Model Honeywell C7015A1076
System Role UV Flame Detector — Sensing Layer of Burner Management System
Detection Technology Ultraviolet (UV) Radiation Sensing
Compatible Control Modules RM7890A1015, RM7895A1014, EC7890B1010 (7800 Series)
Signal Output Flame Relay Signal to Burner Management Relay Module
Supply Voltage 120 VAC / 60 Hz (nominal)
Operating Temperature -40°C to +60°C
Mounting Interface Compatible with Q7800A1005 Wiring Subbase
Communication Layer Hardwired I/O to Logic Solver; DCS/PLC integration via relay contacts
Redundancy Support Dual-detector configuration with C7027A1049 IR Detector
Amplifier Compatibility R7847A1025, R7849A1023
HMI Interface S7800A1001 Keyboard Display Module
Installation Environment Industrial combustion systems: boilers, burners, furnaces, kilns
Warranty warranty terms confirmed during quotation — manufacturing defects and functional performance
Origin United States

System Compatibility Notes

The C7015A1076 achieves its full operational value when deployed within a coordinated Honeywell 7800 Series control architecture. At the control layer, the RM7890A1015 Burner Management Relay Module serves as the primary logic solver, receiving the UV flame signal from the C7015A1076 and executing the burner sequencing program in accordance with EN 298 and NFPA 85 safety standards. The RM7895A1014 provides an alternative relay module option for applications requiring expanded input/output capacity or different timing configurations.

Signal amplification is handled by the R7847A1025 Solid-State Rectification Amplifier, which conditions the raw detector output before it reaches the relay module. In installations where UV signal strength is marginal due to burner geometry or flame characteristics, the R7849A1023 UV Amplifier provides additional gain, ensuring reliable flame discrimination across the full operating range of the burner. These amplifier modules mount directly to the relay module chassis, maintaining a compact and organized control panel layout.

The Q7800A1005 Wiring Subbase standardizes field wiring termination across all 7800 Series components, providing clearly labeled terminal blocks that simplify installation, inspection, and future modifications. The S7800A1001 Keyboard Display Module connects to the relay module and provides real-time display of flame signal strength, system status, and diagnostic fault codes — enabling operators and maintenance technicians to assess system health without specialized test equipment.

For applications requiring expanded burner control capability, the EC7890B1010 Expanded Capability Burner Controller integrates additional I/O points and communication interfaces, supporting more complex burner management sequences and enabling integration with plant-level DCS platforms. The C7027A1049 Infrared Flame Detector complements the C7015A1076 in dual-technology detection configurations, providing a secondary sensing channel that validates UV flame signals and reduces the risk of spurious trips in environments with potential UV interference sources.

Industrial Application Notes

The Honeywell C7015A1076 is deployed across a wide range of industrial combustion applications where reliable flame detection is a safety-critical requirement. In power generation facilities, the detector integrates with boiler management systems controlling natural gas and fuel oil burners, providing the flame presence verification required for safe burner light-off and continuous operation monitoring. The UV sensing technology is well-suited to the clean, high-intensity flames produced by gas-fired power boilers, where rapid flame response and high signal-to-noise ratio are essential.

In petrochemical and refinery applications, the C7015A1076 is used in process heater and fired equipment management systems, where it operates alongside safety instrumented systems (SIS) designed to IEC 61511 requirements. The detector’s compatibility with Honeywell’s 7800 Series relay modules enables straightforward integration into existing safety loop architectures, supporting both new installations and retrofit projects on aging combustion equipment.

District heating and industrial boiler plants rely on the C7015A1076 for continuous flame monitoring across multiple burner zones. In these multi-burner installations, individual C7015A1076 detectors are assigned to each burner, with their signals aggregated at the control layer by multiple RM7890A1015 relay modules operating in a coordinated sequence. This distributed sensing architecture ensures that a single burner fault does not compromise the overall heating system, supporting the high-availability requirements of district energy networks.

In food processing, pharmaceutical manufacturing, and industrial drying applications, the C7015A1076 provides flame safeguard functionality for direct-fired air heaters and process dryers. These applications demand precise burner control and rapid flame failure response to protect both product quality and personnel safety. The detector’s fast UV response time and compatibility with the 7800 Series control platform make it a reliable choice for these demanding process environments.

Product Compatibility FAQ

Q1: Is the C7015A1076 compatible with all 7800 Series Burner Management Relay Modules?
The C7015A1076 is designed for use with Honeywell’s 7800 Series relay modules, including the RM7890A1015 and RM7895A1014. Compatibility depends on the specific relay module model and its configured amplifier input type. The R7847A1025 and R7849A1023 amplifier modules are typically required to interface the detector output with the relay module input circuit. Engineers should verify the relay module’s amplifier input specification against the C7015A1076 output characteristics before finalizing the system design. ZYPLC’s technical team can assist with compatibility verification for specific installation configurations.

Q2: Can the C7015A1076 be used in a redundant flame detection architecture, and what components are required?
Yes. The C7015A1076 supports redundant detection configurations when paired with a secondary detector such as the C7027A1049 Infrared Flame Detector. In a dual-technology architecture, both detectors monitor the same flame, and the relay module logic requires confirmation from both sensing channels before permitting burner operation. This configuration significantly reduces the probability of both spurious trips and undetected flame failures, meeting the requirements of SIL 2 safety instrumented functions in many combustion applications. The Q7800A1005 Wiring Subbase accommodates dual-detector wiring within a standard panel layout.

Q3: What does the warranty terms confirmed during quotation cover, and how does ZYPLC support long-term maintenance requirements?
All C7015A1076 units supplied by ZYPLC are covered by a warranty terms confirmed during quotation against manufacturing defects and functional performance failures under normal operating conditions. In the event of a warranty claim, ZYPLC provides replacement units from availability subject to RFQ confirmation, minimizing system downtime. For long-term maintenance planning, ZYPLC maintains inventory of the C7015A1076 alongside compatible 7800 Series components — including the RM7890A1015, R7847A1025, S7800A1001, and Q7800A1005 — enabling facilities to source complete replacement kits from a single supplier. Customers are encouraged to contact ZYPLC’s technical team to establish a maintenance inventory plan aligned with their scheduled outage cycles.