Skip to main content

Mitsubishi Electric

Mitsubishi LSC-300-PCB Magnetic Contactor for FA Series Systems

Mitsubishi LSC-300-PCB magnetic contactor for FA Series systems. Protocol-ready motor control, SCADA integration, warranty terms confirmed during quotation. export shipping options available.

SKULSC-300-PCB BrandMitsubishi Electric TypeMagnetic Contactor Seriesork Interface for FA Series OriginJP CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need quotation, availability, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

In modern industrial environments, every device on the factory floor must participate in a unified data ecosystem. The Mitsubishi LSC-300-PCB magnetic contactor is engineered not merely as a switching element, but as a critical node in the FA Series automation architecture — bridging field-level motor control with higher-layer SCADA, HMI, and PLC communication networks. As smart manufacturing demands real-time visibility from sensor to cloud, the LSC-300-PCB delivers the reliability, signal integrity, and system compatibility that industrial connectivity requires.

Designed for integration within Mitsubishi Electric’s FA Series ecosystem, the LSC-300-PCB operates alongside programmable logic controllers, remote I/O modules, variable frequency drives, and industrial gateways to form a coherent, low-latency automation backbone. Whether deployed in motor starter panels, MCC cabinets, or distributed control architectures, this contactor supports the data-driven workflows that define Industry 4.0 production lines.

Compatibility & Integration Notes

Parameter Specification
SKU LSC-300-PCB
Brand / Series Mitsubishi Electric / FA Series
Product Type Magnetic Contactor (PCB Mount)
Communication Protocol CC-Link IE Field, MELSEC-NET/H compatible ecosystem
Interface Type PCB-mount terminal, DIN rail compatible panel integration
Control Voltage FA Series standard coil voltage range
Network Compatibility Mitsubishi MELSEC iQ-R, iQ-F, Q Series PLC platforms
System Application Motor control centers, smart factory automation, SCADA-linked panels
Gateway Integration Compatible with CC-Link IE to PROFIBUS/EtherNet/IP gateway modules
Origin Japan
Warranty 12 Months

Connected Automation Data Flow

The LSC-300-PCB sits at the intersection of power switching and intelligent data flow. In a typical FA Series deployment, a Mitsubishi MELSEC iQ-R Series PLC (such as the R04CPU or R08CPU) issues motor start/stop commands through a CC-Link IE Field Network master module, propagating control signals down to remote I/O stations and contactor control relays in real time. The LSC-300-PCB responds to these commands with sub-cycle switching precision, feeding status feedback — contact state, coil energization confirmation — back upstream to the PLC for closed-loop verification.

At the HMI layer, a Mitsubishi GOT2000 Series touch panel (GT2710-VTBA or similar) displays live motor run/stop status, contactor cycle counts, and alarm conditions sourced directly from the PLC data registers linked to the LSC-300-PCB’s auxiliary contacts. Operators on the plant floor gain instant visibility without manual inspection of the panel.

Variable frequency drives such as the Mitsubishi FR-E800 Series inverter are frequently wired in series with the LSC-300-PCB in star-delta or bypass configurations. The contactor’s fast-make, fast-break characteristics ensure clean handoff between drive-controlled and direct-on-line motor operation, while the FR-E800’s built-in CC-Link IE Field Basic port keeps drive status synchronized with the SCADA layer.

For remote monitoring and diagnostics, a Mitsubishi MR-JE Series servo amplifier or an NZ2GF2B1-16D remote I/O module on the same CC-Link IE segment can relay contactor health data — including contact wear indicators derived from operation counters — to an edge gateway such as the Mitsubishi MELIPC MI5122-VW industrial PC. This edge node aggregates field data and pushes structured JSON payloads to cloud-based MES or ERP platforms, completing the digital thread from motor terminal to enterprise dashboard.

In multi-panel installations, Mitsubishi QJ71E71-100 Ethernet interface modules installed in Q Series base units provide the TCP/IP backbone that connects distributed MCC panels across the plant network. The LSC-300-PCB’s status data, collected by local PLCs, is polled by SCADA servers running Mitsubishi GENESIS64 or third-party platforms via OPC-UA, enabling plant-wide motor fleet management from a single supervisory console.

Power quality and protection are maintained by coordinating the LSC-300-PCB with Mitsubishi TH-N Series thermal overload relays, which provide motor protection data — trip current, thermal state — that feeds back into the PLC alarm management system. This integration ensures that every motor protection event is logged, timestamped, and escalated through the SCADA alarm hierarchy without manual intervention.

Solving Data Isolation in Industrial Sites

Legacy factory environments frequently suffer from protocol fragmentation: motor control panels operating on hardwired I/O, drives communicating over proprietary serial links, and SCADA systems unable to reach field devices without costly protocol converters. The LSC-300-PCB, deployed within a Mitsubishi FA Series architecture, directly addresses these data isolation challenges.

By standardizing on CC-Link IE Field Network — a Gigabit Ethernet-based open industrial protocol — the FA Series ecosystem eliminates the need for separate protocol gateways between the contactor control layer and the PLC. Status signals that previously required dedicated hardwired home runs are now transmitted as cyclic data frames over a single fiber or copper network segment, reducing wiring costs and improving signal integrity across long cable runs in large facilities.

Remote diagnostics become practical when the LSC-300-PCB’s auxiliary contact states are mapped to PLC data registers accessible via SCADA. Maintenance engineers can monitor contactor health, predict contact wear, and schedule preventive replacement during planned downtime windows — all without dispatching technicians to the panel. This shift from reactive to predictive maintenance directly reduces unplanned production stoppages.

Production line transparency is achieved by integrating contactor operation data into OEE (Overall Equipment Effectiveness) calculations. Each motor start event recorded by the LSC-300-PCB contributes to cycle time analysis, energy consumption tracking, and throughput reporting — data that plant managers use to identify bottlenecks and optimize production scheduling.

System expansion is straightforward within the FA Series framework. Additional LSC-300-PCB contactors can be added to existing CC-Link IE segments without reconfiguring the network topology, and new remote I/O stations can be commissioned using Mitsubishi’s GX Works3 engineering software with automatic parameter upload — minimizing engineering time for capacity expansions or line reconfigurations.

Industrial Connectivity FAQ

Q1: What communication protocols are compatible with the LSC-300-PCB in a Mitsubishi FA Series system?
The LSC-300-PCB integrates into Mitsubishi FA Series architectures that utilize CC-Link IE Field Network, MELSEC-NET/H, and standard Ethernet/IP protocols via gateway modules. Its auxiliary contacts and coil control interface directly with MELSEC iQ-R and iQ-F PLC I/O modules, enabling seamless protocol-level data exchange without additional signal converters.

Q2: How does the LSC-300-PCB support real-time monitoring and alarm management in SCADA systems?
Auxiliary contact states from the LSC-300-PCB are mapped to PLC data registers and transmitted cyclically over the CC-Link IE network to SCADA servers. Alarm conditions — such as contactor failure to close or unexpected trip — are detected within one PLC scan cycle (typically 1–10 ms) and escalated through the SCADA alarm management system, ensuring operators receive real-time fault notifications with full timestamp and location data.

Q3: Can the LSC-300-PCB be integrated into existing non-Mitsubishi control systems?
Yes. While optimized for Mitsubishi FA Series platforms, the LSC-300-PCB’s standard coil control interface (24VDC or AC variants) and auxiliary contact outputs are compatible with any PLC or control system capable of discrete I/O. For protocol-level integration with non-Mitsubishi SCADA or DCS platforms, CC-Link IE to EtherNet/IP or PROFIBUS gateway modules provide transparent data bridging.

Q4: What quality assurance and warranty coverage applies to the LSC-300-PCB?
Every LSC-300-PCB unit supplied by ZYPLC undergoes pre-shipment functional testing, including coil energization verification, contact resistance measurement, and auxiliary contact continuity checks. A warranty terms confirmed during quotation covers manufacturing defects and premature contact failure under normal operating conditions. Expedited replacement support is available for critical production applications to minimize downtime exposure.