Omron
OMRON DRT2-TS04P Industrial Network Interface for DRT2 Systems
OMRON DRT2-TS04P DeviceNet thermocouple I/O module for DRT2 systems. Protocol conversion, SCADA integration, real-time monitoring. warranty terms confirmed during quotation.
Omron
OMRON DRT2-TS04P DeviceNet thermocouple I/O module for DRT2 systems. Protocol conversion, SCADA integration, real-time monitoring. warranty terms confirmed during quotation.
Technical Details
Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.
The OMRON DRT2-TS04P is a high-performance Compobus/D analog I/O module engineered for demanding industrial environments where real-time data acquisition, protocol transparency, and network reliability are non-negotiable. As part of the OMRON DRT2 Series, this module serves as a critical communication node between field-level sensors, PLC controllers, remote I/O stations, HMI panels, SCADA systems, and upper-level MES platforms — forming the backbone of a connected, intelligent manufacturing site.
Designed around the DeviceNet (Compobus/D) open fieldbus protocol, the DRT2-TS04P enables seamless integration of thermocouple temperature signals into the broader industrial network. With 4 analog input channels optimized for thermocouple sensors, it captures precise thermal data at the field level and transmits it across the DeviceNet segment to the master controller — eliminating signal isolation, reducing wiring complexity, and enabling centralized monitoring without sacrificing measurement accuracy.
| Parameter | Specification |
|---|---|
| SKU | DRT2-TS04P |
| Brand | OMRON |
| Series | DRT2 (Compobus/D Remote I/O) |
| Communication Protocol | DeviceNet (Compobus/D) |
| Interface Type | DeviceNet Slave Node |
| Analog Input Channels | 4 Channels (Thermocouple Input) |
| Transmission Capability | Real-time analog data over DeviceNet fieldbus |
| Network Compatibility | DeviceNet, Compobus/D, OMRON CJ/CS/NX/NJ PLC Networks |
| System Application | SCADA Integration, HMI Monitoring, Remote I/O, Smart Factory |
| Origin | Japan |
| Warranty | warranty terms confirmed during quotation |
In a typical smart factory deployment, the DRT2-TS04P sits at the edge of the process layer, collecting thermocouple signals from temperature sensors such as the OMRON E5CC series temperature controllers or K-type thermocouple probes mounted on furnaces, ovens, and heat-treatment lines. These analog signals are digitized and transmitted over the DeviceNet segment to a DeviceNet master scanner — most commonly the CJ1W-DRM21 or CS1W-DRM21 DeviceNet master unit installed in an OMRON CJ2M or CS1 PLC rack.
The PLC CPU — such as the OMRON CJ2M-CPU31 or the compact NX1P2 machine automation controller — processes the incoming temperature data in real time, executing control logic for alarm thresholds, PID regulation, and interlock sequences. Alongside the DRT2-TS04P, other DRT2 Series remote I/O modules such as the DRT2-ID16 (16-point digital input) and DRT2-OD16 (16-point digital output) extend the DeviceNet network to cover discrete I/O points across the production floor, all managed through the same master scanner without additional wiring infrastructure.
Upstream from the PLC, the live process data — including temperature readings from the DRT2-TS04P — is forwarded via EtherNet/IP or FINS protocol to an OMRON NS-series HMI or NB-series HMI panel installed at the operator station. Operators can monitor real-time temperature trends, acknowledge alarms, and adjust setpoints directly from the HMI without interrupting the production cycle. For multi-zone temperature management, the OMRON EJ1 modular temperature controller can work in parallel with the DRT2-TS04P, providing closed-loop control at the device level while the DRT2-TS04P feeds raw thermocouple data into the network for SCADA logging and historical trending.
At the SCADA and MES layer, the aggregated data from the DeviceNet network — including all analog values captured by the DRT2-TS04P — is collected by an industrial edge gateway or SCADA server running OMRON-compatible OPC-UA or FINS drivers. This enables plant-wide visibility, cross-line benchmarking, and predictive maintenance analytics based on continuous temperature monitoring across multiple production zones.
One of the most persistent challenges in legacy manufacturing environments is protocol fragmentation — where field devices, PLCs, and upper systems speak different communication languages, creating data silos that prevent real-time visibility and slow down decision-making. The OMRON DRT2-TS04P directly addresses this by acting as a protocol gateway at the analog signal level: it converts raw thermocouple voltages into structured DeviceNet data packets that any DeviceNet-compatible master can read, log, and act upon.
For sites transitioning from standalone temperature controllers to networked automation, the DRT2-TS04P eliminates the need for dedicated analog wiring runs back to the control panel. Instead, a single DeviceNet trunk cable carries data from multiple DRT2 slave modules — including the DRT2-TS04P — back to the master PLC, dramatically reducing installation costs and cable management complexity. This architecture also simplifies remote diagnostics: maintenance engineers can query the status of each DeviceNet node, including the DRT2-TS04P, from the PLC programming software or SCADA dashboard without physically accessing the field device.
Production line transparency is further enhanced by the module’s ability to feed temperature data into SCADA alarm management systems. When a thermocouple reading exceeds a defined threshold, the PLC triggers an alarm that propagates through the HMI, SCADA, and optionally to mobile notification systems — enabling rapid response before product quality is compromised. System expansion is equally straightforward: additional DRT2 Series modules can be added to the DeviceNet segment up to the network’s node limit, allowing the automation architecture to grow alongside production capacity without redesigning the communication infrastructure.
Q1: What is the communication latency of the DRT2-TS04P on a DeviceNet network?
The DRT2-TS04P operates as a DeviceNet slave node with cycle times determined by the master scanner’s polling interval. In a standard OMRON CJ1W-DRM21 or CS1W-DRM21 master configuration, communication cycle times are typically in the range of 2–10 ms depending on the number of nodes and the configured baud rate (125 kbps, 250 kbps, or 500 kbps), making it suitable for real-time temperature monitoring and closed-loop control applications.
Q2: Is the DRT2-TS04P compatible with non-OMRON DeviceNet masters?
Yes. As a standard DeviceNet (IEC 62026-3) compliant slave device, the DRT2-TS04P can be integrated with any DeviceNet-compatible master scanner from other vendors. However, for optimal performance, seamless EDS file integration, and full diagnostic support, pairing with OMRON CJ-series or CS-series DeviceNet master units is recommended.
Q3: How does the DRT2-TS04P support network stability in harsh industrial environments?
The DRT2-TS04P is designed to operate reliably in industrial environments with wide temperature ranges, electrical noise, and vibration. Its DeviceNet interface includes built-in error detection and node status reporting, allowing the PLC master to identify communication faults at the node level and trigger appropriate alarms or fallback logic without disrupting the rest of the network segment.
Q4: What warranty and pre-shipment testing does the DRT2-TS04P come with?
Every DRT2-TS04P unit supplied by ZYPLC undergoes functional testing prior to shipment, verifying communication integrity, analog channel accuracy, and DeviceNet node registration. All units are covered by a warranty terms confirmed during quotation from the date of shipment. Availability is confirmed via RFQ for shipment arranged after confirmation, with worldwide shipping supported. For procurement inquiries, contact ZYPLC at +86 19859288691 or plc.sales@zyplc.com.
© 2026 ZYPLC. All rights reserved. | Contact: +86 19859288691 | plc.sales@zyplc.com