Skip to main content

Pepperl+Fuchs

Pepperl+Fuchs KFD2-VM-Ex1.35 System-Ready Solenoid Driver for KFD2 Architecture

Pepperl+Fuchs KFD2-VM-Ex1.35 solenoid driver for KFD2 architecture. Contextual Integration, 12-Month Warranty. In stock, tested, ready to ship.

SKUKFD2-VM-EX1.35 BrandPepperl+Fuchs TypeSolenoid Driver SeriesKFD2 OriginDE CategoryDrives & Motors
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, subject to stock
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Pepperl+Fuchs KFD2-VM-Ex1.35 System-Ready Solenoid Driver for KFD2 Architecture: Control System Architecture and Upstream–Downstream Coordination

The Pepperl+Fuchs KFD2-VM-Ex1.35 is a galvanically isolated, intrinsically safe solenoid driver designed for seamless integration within the KFD2 series DIN-rail barrier architecture. In modern industrial automation, a solenoid driver is not a standalone component — it is a critical node in the signal chain that connects the safe-area control layer to hazardous-area field actuators. The KFD2-VM-Ex1.35 fulfills this role with precision, providing reliable switching control for solenoid valves in Zone 1 and Zone 2 explosive atmospheres while maintaining full compatibility with the broader KFD2 system platform.

Within a layered automation architecture, the KFD2-VM-Ex1.35 sits at the interface between the I/O layer and the execution layer. It receives discrete output signals from the process control system — typically a PLC or DCS — and converts them into intrinsically safe switching commands for field-mounted solenoid valves. This signal path is fundamental to process safety and operational continuity in industries such as oil and gas, chemical processing, petrochemical refining, water treatment, and power generation.

Architecture Specification Table

Parameter Specification
System Role Intrinsically Safe Solenoid Driver — Execution Layer Interface
SKU / Model KFD2-VM-Ex1.35
Brand / Series Pepperl+Fuchs / KFD2 Series
Supply Voltage 20–30 V DC (via KFD2 Power Rail)
Output Circuit Intrinsically safe, Ex ia IIC, Zone 0/1/2 compatible
Output Current Up to 60 mA (solenoid valve drive)
Galvanic Isolation Yes — safe area / hazardous area fully isolated
Electrical Parameters Uo ≤ 28 V, Io ≤ 93 mA, Po ≤ 650 mW (typical Ex ia parameters)
Communication / Control Discrete I/O (24 V DC logic input from PLC/DCS)
Mounting DIN rail, KFD2 system bus compatible
Housing Width 20 mm single-channel
Operating Temperature -20°C to +60°C
Protection Class IP20 (control cabinet installation)
Certifications ATEX, IECEx, cULus (intrinsic safety)
Origin Germany
Warranty 12-Month Warranty — tested, verified, ready to deploy

Coordinated Control System Design

The KFD2-VM-Ex1.35 achieves its full value when deployed as part of a coordinated KFD2 system architecture rather than as an isolated barrier. In a typical process automation cabinet, the KFD2 Power Rail — such as the KFD2-EB2 active bus module — distributes 24 V DC power across all mounted barriers, eliminating individual power wiring and simplifying cabinet layout. The KFD2-VM-Ex1.35 draws power directly from this rail, ensuring consistent supply voltage and reducing single-point failure risk.

On the control side, the solenoid driver receives its switching command from a PLC digital output module — commonly a Siemens S7-300/S7-400 DO card, a Rockwell ControlLogix output module, or an equivalent DCS marshalling output. The 24 V DC logic signal is processed by the KFD2-VM-Ex1.35 and converted into an intrinsically safe current loop that drives the field solenoid valve. This clean signal boundary between the safe area and the hazardous area is what makes the KFD2 architecture compliant with IEC 60079-11 intrinsic safety standards.

For analog process signals running in parallel — such as pressure transmitter feedback or flow measurement — the KFD2-STC4-Ex1 or KFD2-STC4-Ex2 signal conditioners can be mounted on the same DIN rail, sharing the same power bus and maintaining a consistent wiring philosophy across the entire I/O layer. This uniformity reduces engineering time during commissioning and simplifies long-term maintenance.

In redundant control architectures, the KFD2-VM-Ex1.35 can be paired with a KFD2-SR2-Ex2.W switch amplifier or a KFD2-RSH-Ex1.4S relay module to provide dual-channel solenoid control with independent switching paths. This configuration is commonly required in Safety Instrumented Systems (SIS) where IEC 61511 demands proof-test intervals and redundant actuator paths for SIL 2 or SIL 3 rated loops.

At the field termination level, the KFD2-UT2-Ex1 or similar terminal modules provide a clean interface between the barrier outputs and the field cable marshalling, supporting both conventional and HART-compatible wiring schemes. The consistent 20 mm housing width across the KFD2 product family means that mixed installations — combining solenoid drivers, switch amplifiers, and signal conditioners — maintain a uniform cabinet footprint and predictable cable routing.

For installations requiring remote I/O or fieldbus integration, the KFD2-VM-Ex1.35 can coexist in cabinets alongside Pepperl+Fuchs LB Remote I/O or FB fieldbus barrier modules, allowing hybrid architectures where some loops are hardwired and others are managed via PROFIBUS PA or FOUNDATION Fieldbus. This flexibility is particularly valuable in brownfield upgrades where existing hardwired barriers must be retained alongside new fieldbus infrastructure.

Application in Layered Automation Systems

In petrochemical and refinery applications, the KFD2-VM-Ex1.35 is widely used to control on/off solenoid valves on process shutdown (ESD) systems, where the solenoid must de-energize reliably on loss of signal to achieve a fail-safe closed or fail-safe open valve position. The intrinsic safety output ensures that even in the event of a wiring fault in the hazardous area, the energy available at the field device remains below the ignition threshold of the surrounding atmosphere.

In water treatment and municipal infrastructure projects, the KFD2-VM-Ex1.35 is deployed in pump station control panels where Zone 2 classification applies to wet wells and chemical dosing areas. The compact 20 mm DIN-rail format allows high-density installations in space-constrained marshalling cabinets, and the shared KFD2 power bus reduces the number of individual power supply units required per cabinet.

In mining and mineral processing environments, where dust and gas hazards may coexist, the KFD2-VM-Ex1.35 supports Group IIC (hydrogen) rated installations, providing the highest level of intrinsic safety protection. This makes it suitable for use in underground mining control systems, flotation cell automation, and conveyor interlock circuits where solenoid-operated pneumatic valves control material flow.

In pharmaceutical and fine chemical manufacturing, where process cleanliness and audit traceability are paramount, the KFD2-VM-Ex1.35 supports validation-friendly installations. Its fixed hardware configuration — no internal adjustments required — simplifies IQ/OQ documentation, and the 12-Month Warranty provides procurement teams with a defined support window for spare parts planning and lifecycle management.

Architecture Engineering FAQ

Q1: Is the KFD2-VM-Ex1.35 compatible with both Siemens and Rockwell PLC output modules?
Yes. The KFD2-VM-Ex1.35 accepts a standard 24 V DC discrete input signal, which is the universal output standard for virtually all modern PLC and DCS digital output cards, including Siemens S7-300/400/1500 DO modules, Rockwell ControlLogix and CompactLogix output cards, ABB AC500 DO modules, and Honeywell/Emerson DCS marshalling outputs. No special interface card or signal converter is required on the safe-area side.

Q2: Can the KFD2-VM-Ex1.35 be used in a SIL-rated Safety Instrumented System?
The KFD2-VM-Ex1.35 is designed for use in intrinsically safe solenoid valve control loops. For SIL-rated SIS applications, the overall loop SIL rating depends on the combination of the logic solver, the barrier, and the final element. Pepperl+Fuchs provides FMEDA data and SIL capability documentation for KFD2 series barriers to support IEC 61511 loop calculations. Consult the product safety manual and your functional safety engineer to confirm the complete loop architecture meets the required SIL target.

Q3: What does the 12-Month Warranty cover, and how does it support long-term maintenance planning?
The 12-Month Warranty covers the KFD2-VM-Ex1.35 against manufacturing defects and functional failures under normal operating conditions. For maintenance planning, this warranty period aligns with typical annual proof-test intervals in SIS applications, allowing maintenance teams to schedule barrier replacement or recertification in coordination with planned plant shutdowns. All units supplied by ZYPLC are tested prior to dispatch, and warranty claims are supported directly through our technical team.


© 2026 ZYPLC. All rights reserved.
Original Source: https://zyplc.com
Contact: +86 19859288691 | [email protected]