Schneider Electric RFQ support for Control Board. Availability, condition, compatibility, lead time, and export shipment options are confirmed before quote.

SKU14857820312A04 W814857810111A01 BrandSchneider Electric TypeControl Board SeriesOther series OriginFR CategoryIndustrial Automation Spare Parts
AvailabilityConfirm by RFQ, global sourcing supported
ConditionNew / Refurbished / Tested, confirmed before quote
Lead TimeFast quotation, shipment arranged after confirmation
ShippingDHL / FedEx / UPS worldwide
Need price, stock, or a compatible replacement?

Technical Details

Product specification and sourcing notes

Review the original product details, compatibility notes, and sourcing information in a clearer technical document layout.

Schneider 14857820312A04 W814857810111A01 Control Board for Micrologic

The Schneider Electric 14857820312A04+W814857810111A01 is a precision-engineered control board designed for seamless integration within Micrologic trip unit architectures deployed across Masterpact NT and Masterpact NW series air circuit breakers. Rather than functioning as a standalone component, this board occupies a critical position within the layered control hierarchy of industrial power distribution and automation systems — bridging the intelligence layer of the trip unit with the broader supervisory and protection framework of the installation.

In modern industrial facilities — whether in manufacturing, power generation, petrochemical processing, or water treatment — the reliability of a low-voltage switchgear system depends not on any single component, but on the coherent interaction of every module within the architecture. The 14857820312A04+W814857810111A01 board ensures that the Micrologic trip unit can accurately interpret current measurements, execute protection algorithms, and communicate status data upstream to SCADA or maintenance planning systems without signal degradation or latency. This system integration capability is what distinguishes a well-engineered system from a collection of isolated devices.

From a system architecture perspective, this control board supports the control layer’s interaction with the I/O layer, enabling real-time feedback loops between the circuit breaker’s protection logic and the plant-level automation controller. When paired with a Modbus or IEC 61850 communication gateway, the board’s data output can be aggregated into a unified condition monitoring dashboard, giving operations teams full visibility into load profiles, fault histories, and maintenance schedules.

Product Specification Table

Parameter Specification
Part Numbers 14857820312A04 + W814857810111A01
Brand Schneider Electric
Series Compatibility Micrologic Trip Unit (Masterpact NT / NW)
System Role Trip Unit Control Board — Protection & Measurement Intelligence Layer
Product Type Control Board / PCB Assembly
Communication Capability Compatible with Modbus RTU, IEC 61850 via gateway integration
Electrical Parameters Low-voltage switchgear application; rated per Masterpact platform specifications
Installation Environment Indoor LV switchgear panels, MCC cabinets, power distribution boards
Origin France
Warranty warranty terms confirmed during quotation — covers manufacturing defects and functional failure under normal operating conditions

System Compatibility Notes

The 14857820312A04+W814857810111A01 board achieves its full value when considered within the context of a complete Schneider Electric power and automation architecture. In a typical Masterpact-based MCC or main distribution board, this control board works in concert with the Micrologic 5.0 A or Micrologic 6.0 A trip unit modules, which provide the overload, short-circuit, and earth fault protection logic that the board processes and communicates.

At the power layer, the Masterpact NW08H1 or Masterpact NT06H1 air circuit breakers serve as the primary switching and protection devices, with the Micrologic trip unit — and by extension this control board — embedded within the breaker chassis. The board interfaces with the Micrologic’s internal measurement circuits, ensuring that current transformer signals from the breaker’s sensor assembly are correctly conditioned and interpreted.

For communication and supervisory integration, the IFM (Interface Module) for Masterpact or the BCM (Breaker Communication Module) connects the trip unit’s data output to a plant-level Modbus network or Ethernet backbone. This allows the 14857820312A04+W814857810111A01 board’s processed data — including RMS current, active power, energy consumption, and alarm status — to be transmitted to a PowerLogic ION7650 power meter or a Vijeo Citect SCADA system for centralized monitoring.

In redundant architecture designs, particularly in critical infrastructure such as hospitals, data centers, or offshore platforms, this board supports the use of dual-bus configurations where the Masterpact breaker acts as a bus coupler. The control board’s reliable operation ensures that automatic transfer switching logic, often managed by a Zelio Logic smart relay or a Modicon M340 PLC, receives accurate breaker status signals to execute seamless load transfer without interruption.

At the human-machine interface layer, operators interacting with a Magelis GTO advanced panel or a PowerLogic EGX300 gateway can retrieve real-time protection parameters and historical fault logs that originate from the Micrologic trip unit’s control board. This end-to-end data continuity — from the physical breaker through the control board to the HMI — is the foundation of effective predictive maintenance programs.

Terminal modules such as the Acti9 iOF+SD24 auxiliary contact or the Micrologic’s own ZSI (Zone Selective Interlocking) wiring harness further extend the board’s role in coordinated protection schemes, ensuring that fault isolation is achieved at the lowest possible level of the distribution hierarchy, minimizing disruption to upstream systems.

Industrial Application Notes

In manufacturing environments — particularly automotive assembly lines, food and beverage processing plants, and semiconductor fabrication facilities — the 14857820312A04+W814857810111A01 control board is deployed within main distribution boards (MDBs) and sub-distribution boards (SDBs) that feed critical production equipment. The board’s accurate protection logic prevents nuisance tripping while ensuring genuine fault conditions are isolated within milliseconds, protecting both machinery and personnel.

In the power utility and electrical substation sector, Masterpact-based switchgear equipped with this Micrologic control board is used in generator protection panels, bus section breakers, and incomer protection assemblies. The board’s compatibility with IEC 61850 communication protocols — via appropriate gateway modules — makes it suitable for integration into digital substation architectures where IED (Intelligent Electronic Device) interoperability is mandatory.

Petrochemical and oil and gas facilities rely on this type of control board within hazardous area distribution systems, where the precision of protection settings and the reliability of the trip unit’s electronics are paramount. The board’s robust design, manufactured to Schneider Electric’s stringent quality standards in France, ensures consistent performance across wide temperature ranges and in environments subject to vibration and electromagnetic interference.

Water treatment and municipal infrastructure projects frequently specify Masterpact circuit breakers with Micrologic trip units for pump motor protection, where the control board’s motor protection algorithms — including thermal memory and phase imbalance detection — are essential for extending motor service life and reducing unplanned downtime.

In mining and metallurgical applications, where high-current loads and frequent motor starts place extreme demands on protection systems, the 14857820312A04+W814857810111A01 board’s ability to maintain accurate current measurement under transient conditions ensures that the protection system remains stable and reliable throughout the operational lifecycle of the installation.

Product Compatibility FAQ

Q1: Is the 14857820312A04+W814857810111A01 control board compatible with all Micrologic trip unit variants in the Masterpact range?
This board is specifically designed for the Micrologic trip unit family used in Masterpact NT and NW series air circuit breakers. Compatibility depends on the specific Micrologic variant (e.g., 2.0 A, 5.0 A, 6.0 A, 7.0 A) and the breaker frame size. It is strongly recommended to cross-reference the board’s part numbers against the Masterpact spare parts catalog or consult with a qualified Schneider Electric system integrator before installation to confirm exact compatibility within your existing architecture.

Q2: How does this control board support long-term maintenance and system lifecycle management?
The 14857820312A04+W814857810111A01 board is a direct replacement component for the Micrologic trip unit’s internal electronics, enabling field repair of the trip unit without full breaker replacement. This significantly reduces lifecycle costs in large installations where multiple Masterpact breakers are deployed. All units supplied by ZYPLC are covered by a warranty terms confirmed during quotation, and our technical team can assist with installation guidance, commissioning support, and compatibility verification to ensure the board integrates correctly into your existing control architecture.

Q3: What commissioning steps are required after replacing this control board in an operational system?
After physical installation, the Micrologic trip unit must be re-parameterized using the Micrologic Test Kit or the PowerSuite software tool to restore protection settings (In, Ir, Isd, Ii, Ig) to the values specified in the original protection coordination study. Communication parameters for Modbus or IEC 61850 integration must also be reconfigured. A functional test — including a simulated trip test using the Micrologic test port — should be performed before the breaker is returned to service. ZYPLC’s warranty terms confirmed during quotation covers the board against manufacturing defects throughout this commissioning period and beyond.